Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

PhaseNet batch predictor modifying waveform? #61

Open
wagnerk-89 opened this issue Sep 9, 2022 · 1 comment
Open

PhaseNet batch predictor modifying waveform? #61

wagnerk-89 opened this issue Sep 9, 2022 · 1 comment

Comments

@wagnerk-89
Copy link

wagnerk-89 commented Sep 9, 2022

I have a clean waveform that I am running through the batch predictor, but when it runs through the PhaseNet batch predictor it looks like it is modifying the waveform, and I end up with two P/S picks instead of one. What can I adjust so that it doesn't edit the waveform? See image attached.
phasenet

@wayneweiqiang
Copy link
Collaborator

Hi, the change of amplitude is from normalization. For a long sequence, the normalization is done using short windows of 30s. If you cut a 30s window as input, the waveform won’t change.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants