// Shelly Script example: Shelly Plus 1PM - Notify within active hours when power
// passes a threshold
let CONFIG = {
// Make sure that start precedes end in activeTime, the script does not test for valid interval
activeTime: {
start: "00:00",
end: "05:00",
},
// Notify only once or every time the threshold is passed
notifyOnce: false,
// Which of the device switches to monitor
outputId: 0,
// Power threshold in Watts
outputPowerThreshold: 4,
// Which http endpoint to ping
httpEndpoint: 'https://world.news/powerishigh'
};
function timeStrToMinutes(timeStr) {
let hours = JSON.parse(timeStr.slice(0,2));
let minutes = JSON.parse(timeStr.slice(3));
return hours * 60 + minutes;
}
function notify() {
Shelly.call(
'HTTP.GET',
{url:CONFIG.httpEndpoint}
)
}
let outputStringId = "switch:" + JSON.stringify(CONFIG.outputId);
let startMinutes = timeStrToMinutes(CONFIG.activeTime.start);
let endMinutes = timeStrToMinutes(CONFIG.activeTime.end);
let lastNotifyMinutes = null;
Shelly.addStatusHandler(function (statusNtf) {
if (statusNtf.component !== outputStringId) return;
if (typeof statusNtf.delta.apower === "undefined") return;
if (statusNtf.delta.apower < CONFIG.outputPowerThreshold) return;
let sysStatus = Shelly.getComponentStatus('sys');
let currentMinutes = timeStrToMinutes(sysStatus.time);
if(currentMinutes >= startMinutes && currentMinutes <= endMinutes) {
if(!CONFIG.notifyOnce || (CONFIG.notifyOnce && lastNotifyMinutes === null)) {
notify();
lastNotifyMinutes = currentMinutes;
}
}
if(currentMinutes > endMinutes) {
lastNotifyMinutes = null;
}
});