Confirm why perpendicular baseline is negative in some cases #62

Open
jtherrmann opened this issue May 23, 2023 · 1 comment
Open

Confirm why perpendicular baseline is negative in some cases #62

jtherrmann opened this issue May 23, 2023 · 1 comment

Comments

@jtherrmann
Copy link
Contributor

See the discussion here: #61 (comment)

@cirrusasf
Copy link
Contributor

comparing the meta.txt files produced by hyp3-isce2 and hyp3-gamma for the pair:
S1A_IW_SLC__1SDV_20190610T015047_20190610T015114_027611_031DB6_D8FA
S1A_IW_SLC__1SDV_20190622T015048_20190622T015115_027786_0322F1_7A8E, I found that hyp3-isce2 reports the Perpindicular Baseline: -14.321817636040937, and hyp3-gamma reports the Baseline: -14.845.