-
Notifications
You must be signed in to change notification settings - Fork 1
/
i3blocks.conf
115 lines (102 loc) · 1.99 KB
/
i3blocks.conf
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
# i3blocks config file
#
# Please see man i3blocks for a complete reference!
# The man page is also hosted at http://vivien.github.io/i3blocks
#
# List of valid properties:
#
# align
# color
# command
# full_text
# instance
# interval
# label
# min_width
# name
# separator
# separator_block_width
# short_text
# signal
# urgent
# Global properties
#
# The top properties below are applied to every block, but can be overridden.
# Each block command defaults to the script name to avoid boilerplate.
# command=$SCRIPT_DIR/$BLOCK_NAME
command=~/src/i3blocks/scripts/$BLOCK_NAME
separator_block_width=15
markup=none
# Memory usage
#
# The type defaults to "mem" if the instance is not specified.
[memory]
label=MEM
separator=false
interval=30
[memory]
label=SWAP
instance=swap
separator=false
interval=30
# Disk usage
#
# The directory defaults to $HOME if the instance is not specified.
# The script may be called with a optional argument to set the alert
# (defaults to 10 for 10%).
[disk]
label=HOME
#instance=/mnt/data
interval=30
# Network interface monitoring
#
# If the instance is not specified, use the interface used for default route.
# The address can be forced to IPv4 or IPv6 with -4 or -6 switches.
[iface]
#instance=wlan0
color=#00FF00
interval=10
separator=false
[wifi]
#instance=wlp3s0
interval=10
separator=false
[bandwidth]
#instance=eth0
interval=5
# CPU usage
#
# The script may be called with -w and -c switches to specify thresholds,
# see the script for details.
[cpu_usage]
label=CPU
interval=10
min_width=CPU: 100.00%
#separator=false
#[load_average]
#interval=10
# Battery indicator
#
# The battery instance defaults to 0.
[battery]
# label=BAT
label=⚡
#instance=1
interval=30
# Date Time
#
[time]
command=date '+%d.%m.%Y || %H:%M:%S'
interval=5
# Volume indicator
#
# The first parameter sets the step (and units to display)
# The second parameter overrides the mixer selection
# See the script for details.
[volume]
# label=VOL
label=♪
instance=Master
# instance=PCM
interval=once
signal=10