RIver Profiler System, to be installed July 2019 in Inglefield Land, Greenland (78° north)
The network is operating on the 192.168.1.XXX space, with network mask of 255.255.255.0. The network is run through the powered ethernet switch, which is on digital IO 5. A good IP address for a computer attaching to the network is 192.168.1.42.
The Sutron 9210 XLite is set up with station name rips
.
The logger IP address is 192.168.1.80.
The analog module is located in terminal strip A
and has two functions:
- Take power through terminals 21 and 22.
- Take in light sensor input through terminals 10, 11, and 12.
The digital module is located in terminal strip B
and has three functions:
- Control the Iridium modem through terminal 6, channel 4 I/O.
- Control the ethernet switch and the Velodyne puck through terminal 8, channel 5 I/O.
- Control the camera through terminal 9, channel 6 I/O.
The lidar sensor is a Velodyne VLP-16 with the following attributes:
- Model: VLP-16M12-0.3M-A
- Serial number: 11001191157192
- MAC: 60-76-88-38-18-c0
- IP address: 192.168.1.201