You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Jän 06 11:31:59 messstation opensesame[13532]: thread 'tokio-runtime-worker' panicked at 'called `Result::unwrap()` on an `Err` value: ()', /home/jenkins/workspace/opensesame_fixes/src/clima_sensor_us.rs:255:72
Jän 06 11:31:59 messstation opensesame[13532]: note: run with `RUST_BACKTRACE=1` environment variable to display a backtrace
@fel115 do you have an idea what this could be? Any progress on the blog for Olimex?
The text was updated successfully, but these errors were encountered:
Yes, it seems that in line 249 the value of the clima sensor is 0xFFFFFFFF which is the error code for unsigned 32. So before using the Air Temp and Mean Wind Speed values we need to check if the conv_vec_to_value_s or conv_vec_to_value_s have any error.
Maybe on too strong wind?
@fel115 do you have an idea what this could be? Any progress on the blog for Olimex?
The text was updated successfully, but these errors were encountered: