Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathvcc_tewi.py
145 lines (110 loc) · 4.8 KB
/
vcc_tewi.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
__author__ = 'PeterE-Mac'
import vcc_functions
import vcc_input
input_data = vcc_input.real_system2()
compressor_extension = '-4GE-30Y.xls'
folder = '../../Report/LaTeX/data/'
k = 273.15
m = 10
L_annual = 0.125
n = 15
a_recovery = 0.95
beta = 0.405
time = 24 * 365 * 0.75
refs = [
{
'name':'R404A',
'GWP':3922,
'direct':0.0,
'indirect':0.0,
'e_annual':0.0
},
{
'name':'R448A',
'GWP':1273,
'direct':0.0,
'indirect':0.0,
'e_annual':0.0
},
{
'name':'R449A',
'GWP':1282,
'direct':0.0,
'indirect':0.0,
'e_annual':0.0
},
]
TEWI_direct = open(str("%s%s.dat" % (folder, 'TEWI-direct')), 'w+')
TEWI_indirect = open(str("%s%s.dat" % (folder, 'TEWI-indirect')), 'w+')
TEWI_direct.write("CO2e refrigerant\n")
TEWI_indirect.write("CO2e refrigerant\n")
# Instantiate Vcc:s for each refrigerant
for r in range(0, len(refs)):
locals()["REF_" + refs[r]['name']] = vcc_input.refrigerant(refs[r]['name'])
locals()["VCC_" + refs[r]['name']] = vcc_functions.Vcc(locals()["REF_" + refs[r]['name']])
locals()["VCC_" + refs[r]['name']].set_input_data(input_data)
locals()["VCC_" + refs[r]['name']].set_compressor_data(refs[r]['name'] + compressor_extension)
locals()["VCC_" + refs[r]['name']].calculate()
print("---")
print("REF : Qdot2 : mdot : d0 : Qvol : P : P' : etais : E_ann : cop2 : DisT : beta: TEWI")
for r in range(0, len(refs)):
# The degraded real compressor efficiency
degraded_efficiency = input_data['efficiency_isentropic'] * locals()["VCC_" + refs[r]['name']].isentropic_efficiency()/locals()["VCC_" + refs[0]['name']].isentropic_efficiency()
# Set the degraded compressor efficiency
# The volumetric flow rate from the real compressor data, same due to preserved mechanical properties
locals()["VCC_" + refs[r]['name']].set_volumetric_flow_rate(locals()["VCC_" + refs[r]['name']].volumetric_flow_rate())
locals()["VCC_" + refs[r]['name']].set_compressor_data(degraded_efficiency)
locals()["VCC_" + refs[r]['name']].calculate()
locals()["VCC_" + refs[r]['name']].plot_hlogp()
# Cooling capacity compensation needed
# Since the cooling capacity drops for the retrofit refrigerants the compressor must run more of the time
rel_cool_cap = locals()["VCC_" + refs[r]['name']].cooling_capacity()/locals()["VCC_" + refs[0]['name']].cooling_capacity()
P_compensated = locals()["VCC_" + refs[r]['name']].compressor_power() / rel_cool_cap
# System dependent variables
refs[r]['e_annual'] = P_compensated * time / 1e3
# The parts of TEWI
leakage = refs[r]['GWP'] * m * L_annual * n
recovery = refs[r]['GWP'] * m * (1 - a_recovery)
indirect = refs[r]['e_annual'] * beta * n
refs[r]['direct'] = leakage + recovery
refs[r]['indirect'] = indirect
#print((refs[r]['GWP'] - refs[0]['GWP']) * m * L_annual * n)
#print(refs[r]['GWP'] - refs[0]['GWP']) * m * (1 - a_recovery)
#print((refs[0]['e_annual'] - refs[r]['e_annual']) * n)
if r > 0:
#beta_max = (refs[0]['direct']+refs[0]['indirect'] - refs[r]['direct']) / (refs[r]['e_annual'] * n)
beta_max = (
(refs[0]['GWP'] - refs[r]['GWP']) * m * L_annual * n +
(refs[0]['GWP'] - refs[r]['GWP']) * m * (1 - a_recovery)
) / \
(
(refs[r]['e_annual'] - refs[0]['e_annual']) * n
)
else:
beta_max = 0
tewi = leakage + recovery + indirect
TEWI_direct.write(str("%f %s\n" % ((leakage + recovery)/1e3, refs[r]['name'])))
TEWI_indirect.write(str("%f %s\n" % (indirect/1e3, refs[r]['name'])))
print(locals()["VCC_" + refs[r]['name']].T(3)-273.15)
print("%s : %.1f : %.1f : %.0f : %.1f : %.2f : %.2f : %.2f : %.3f : %.0f : %.2f : %.0f : %.1f : %.1f" %
(
refs[r]['name'],
locals()["VCC_" + refs[r]['name']]._h[0] - locals()["VCC_" + refs[r]['name']]._h[6],
locals()["VCC_" + refs[r]['name']]._h[1] - locals()["VCC_" + refs[r]['name']]._h[0], #locals()["VCC_" + refs[r]['name']].cooling_capacity()/1e3,
locals()["VCC_" + refs[r]['name']].mass_flow_rate()*3600,
locals()["VCC_" + refs[r]['name']]._d[0],
locals()["VCC_" + refs[r]['name']].volumetric_cooling_capacity()/1e3,
locals()["VCC_" + refs[r]['name']].compressor_power()/1e3,
P_compensated/1e3,
degraded_efficiency,
refs[r]['e_annual'],
locals()["VCC_" + refs[r]['name']].cop_2(),
locals()["VCC_" + refs[r]['name']].discharge_temperature()-k,
beta_max,
tewi
)
)
# Reset the compressor
locals()["VCC_" + refs[r]['name']].set_compressor_data(refs[r]['name'] + compressor_extension)
locals()["VCC_" + refs[r]['name']].calculate()
print(" ")