function SoftCodeHandler(softCode)
%soft codes 1-10 reserved for odor delivery
%soft code 11-20 reserved for PulsePal sound delivery
%soft code 21-30 reserved for PulsePal frequency delivery
%soft code 31-40 reserved for laser stimulation protocols
global BpodSystem
global TaskParameters
if softCode < 11 %for olfactory
if BpodSystem.Data.Custom.OlfactometerStartup %if there has been a non-auditory trial and thus olfactometer initialized
firstbank = ['Bank' num2str(TaskParameters.GUI.OdorA_bank)];
secbank = ['Bank' num2str(TaskParameters.GUI.OdorB_bank)];
if softCode < 9
if ~BpodSystem.EmulatorMode
CommandValve = Valves2EthernetString(firstbank, softCode, secbank, softCode); % softCode := desired valve number
TCPWrite(BpodSystem.Data.Custom.OlfIp, 3336, CommandValve);
end
elseif softCode == 9
nextTrial = numel(BpodSystem.Data.Custom.TrialNumber) + 2;
OdorA_flow = BpodSystem.Data.Custom.OdorFracA(nextTrial);
OdorB_flow = 100 - OdorA_flow;
if ~BpodSystem.EmulatorMode
SetBankFlowRate(BpodSystem.Data.Custom.OlfIp, TaskParameters.GUI.OdorA_bank, OdorA_flow)
SetBankFlowRate(BpodSystem.Data.Custom.OlfIp, TaskParameters.GUI.OdorB_bank, OdorB_flow)
end
end
end %if olfactometer initialized
end %if olfactory soft codes
if softCode > 10 && softCode < 21 %for auditory clicks
if ~BpodSystem.EmulatorMode
if softCode == 11 %noise on chan 1
ProgramPulsePal(BpodSystem.Data.Custom.PulsePalParamFeedback);
SendCustomPulseTrain(1,cumsum(randi(9,1,601))/10000,(rand(1,601)-.5)*20); % White(?) noise on channel 1+2
SendCustomPulseTrain(2,cumsum(randi(9,1,601))/10000,(rand(1,601)-.5)*20);
TriggerPulsePal(1,2);
ProgramPulsePal(BpodSystem.Data.Custom.PulsePalParamStimulus);
elseif softCode == 12 %beep on chan 2
ProgramPulsePal(BpodSystem.Data.Custom.PulsePalParamFeedback);
SendCustomPulseTrain(2,0:.001:.3,(ones(1,301)*3)); % Beep on channel 1+2
SendCustomPulseTrain(1,0:.001:.3,(ones(1,301)*3));
TriggerPulsePal(1,2);
ProgramPulsePal(BpodSystem.Data.Custom.PulsePalParamStimulus);
end
end
end
if softCode > 20 && softCode < 31 %for auditory freq
if softCode == 21
if BpodSystem.Data.Custom.PsychtoolboxStartup
PsychToolboxSoundServer('Play', 1);
end
end
if softCode == 22
if BpodSystem.Data.Custom.PsychtoolboxStartup
PsychToolboxSoundServer('Stop', 1);
end
end
end
%laser stimulation protocols
if softCode > 30 && softCode < 41 %for laser stuff
if softCode==31
if BpodSystem.Data.Custom.LaserTrial(end) && TaskParameters.GUI.LaserSoftCode %laser trial and laser via softcode setting
if TaskParameters.GUI.LaserTimeInvestment
%this soft code 'solution' only works for time investment
%inhibition with a significant delay to allow for loading
%the soft code. stupid hack bc PulsePal only supports 2
%custom pulse trains and you can only have 1 pulsepal.
%soft code is called at beginning of time investment to
%load pulsepal matrix for laser stimulation
Params=struct();
Params.Length=TaskParameters.GUI.LaserTrainDuration_ms/1000; %in sec. train INCLUDES RAMP
Params.Ramp = TaskParameters.GUI.LaserRampDuration_ms/1000;
Params.Amp = TaskParameters.GUI.LaserAmp;
Params.TriggerOutChan=3;
Params.LaserOutChan=4;
Params.TriggerInChan=2;
Params.CustomPulseTrainID=1;
Params.DelayStart=BpodSystem.Data.Custom.LaserTrialTrainStart(end);
P=configurePulsePalLaser_CustomTrain(Params);
end
end
SendBpodSoftCode(1); %send back to Bpod that we're done here, only then state matrix continues
end
end
% switch odorID
% case 0
% CommandValveMinOil = Valves2EthernetString(firstbank, 2, secbank, 2);
% TCPWrite(BpodSystem.Data.Custom.OlfIp, 3336, CommandValveMinOil);
% case 1
% CommandValveScent = Valves2EthernetString(firstbank, 1, secbank, 1); % From RechiaOlfactometer plugin. Simultaneously sets banks 1 and 2 to valve 1
% TCPWrite(BpodSystem.Data.Custom.OlfIp, 3336, CommandValveScent);
end