This is a part of the log by the way: 2024-05-28 14:39:37.074 [update notice] received read hmu unknownMB513h0528 QQ=10: 01 |
@LukasGrebe If I address it directly, like so: I do get a proper respons... |
HA discovery is part of ebusd project, this addon has nothing to do. Since Alpine Linux can't use the latest version of ebusd, we need to wait, possibly many months for another ebusd release. |
without having spent much time looking into it: is it related to this? john30/ebusd#1245 so changing the mqtt-hassio.cfg might fix this?! |
Do you mean command line parameters? You can use Or are you looking for something different? |
according to @universal's answer, you can adjust your ...and the "pressure" is still not merged to the upstream 23.3 config.... |
This my config:
scanconfig: true
loglevel_all: notice
mqtttopic: ebusd
mqttint: /etc/ebusd/mqtt-hassio.cfg
mqttjson: true
mode: enh
network_device: 192.168.108.39:3335
configpath: /config/ebusd-configuration/ebusd-2.1.x/en
2ad9b828-ebusd:/# ebusctl info
version: ebusd 23.2.p20230716
update check: version 23.3 available, broadcast.csv: different version available, memory.csv: different version available, vaillant/08.hmu.csv: different version available, vaillant/broadcast.csv: different version available, vaillant/errors.inc: different version available, vaillant/general.csv: different version available, vaillant/hcmode.inc: different version available
device: 192.168.108.39:3335, enhanced
signal: acquired
symbol rate: 122
max symbol rate: 173
min arbitration micros: 1
max arbitration micros: 75
min symbol latency: 15
max symbol latency: 55
scan: finished
reconnects: 0
masters: 5
messages: 235
conditional: 0
poll: 89
update: 15
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=HMU00;SW=0902;HW=5103", loaded "vaillant/08.hmu.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=CTLV3;SW=0709;HW=3704"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address 71: master #9
address 76: slave #9, scanned "MF=Vaillant;ID=VWZIO;SW=0202;HW=0103"
address f1: master #10
address f6: slave #10, scanned "MF=Vaillant;ID=NETX3;SW=0119;HW=0404"
Despite pointing at a custom file for my 08.hmu, it seems it is not loading the correct csv?
The display of the Vaillant VZWAI e.g. does show compressor RPS, modulation rate, flow, etc, but the output of the addon does not.
These parameters are present though in the linked csv
How can I address this issue?