Skip to content

Latest commit

 

History

History
338 lines (283 loc) · 17 KB

README.md

File metadata and controls

338 lines (283 loc) · 17 KB

Breach Toolbox

Introduction

Breach is a Matlab toolbox for time series analysis and simulation-based analysis of dynamical/CPS/Hybrid systems. It can be useful to the prospective user (you) in the following situations:

  • You have time series data and wants to check whether it satisfies some property
  • You need signal temporal logic (STL) monitoring capability, e.g., to check formal requirements on your data
  • You have a Simulink models and wants to perform extensive testing by running multiple simulations (e.g., parameter sweep) and quickly browse through the results, and/or assert whether some (STL) property is satisfied by simulations (random/Monte-Carlo testing)
  • You need to falsify an STL requirement using various optimization algorithm, i.e., find test cases of interest
  • You want to do some or all of the above to for a model implemented with a simulator other than Simulink.

The following describes the initial steps to get started with the above tasks.

Getting started

Setup

To setup and use Breach, start Matlab and run InitBreach from the main Breach folder. This needs only to be done once per Matlab session.

Builtin demos

Type BrDemo. and Tab key to get a list of available scripts to run for testing and demoing the toolbox. E.g.,

>> BrDemo.AFC_1_Interface

Running GenDoc() will run all demos and publish results into the Doc/index.html folder. Note that this operation can take some time to complete. The index files is generated early in the process and the first sections are quickly available.

Contact/Support

Contact info at decyphir dot com to report bugs, for help, complaints, support, etc.

Importing time series data

Breach handles times series as traces, which are objects consisting of data indexed with a time array, i.e., a strictly increasing array starting at 0. For example:

not_time = [3 4 1 7];         % not valid because it is not increasing
not_time_either = [ 3 4 5 7]; % not valid because the first element is not 0
ok_time = [0 3 4 5 7];        % valid     

A trace can be imported in Breach as 2d arrays where the first column is the time array. The relevant object is a BreachTraceSystem. We create one by declaring the names of the signal traces it will contain, where a signal a function of time mapping a time value to a scalar. Below we create one such object for, say, temperature and humidity data:

Bdata = BreachTraceSystem({'temperature', 'humidity'});

It contains no data at this point. Next we create some artificial data corresponding to one hypothetical day of measurment, and add it to B.

time = 0:.1:24; % in hours
temperature = 10 + 15*cos(pi*(time-3)/12+pi)+sin(pi/2*time); % in Celsius deg
humidity = 50 + 10*cos(pi*(time+2)/12)+sin(pi/3*time); % in percents
trace = [time' temperature' humidity']; % combine into a trace, column oriented
Bdata.AddTrace(trace);

A BreachTraceSystem object can contain multiple traces. Repeating the AddTrace call with a different trace will result in B containing two traces, etc. Traces can be plotted using the PlotSignals method:

>> Bdata.PlotSignals();

Monitoring Signal Temporal Logic (STL) Formulas

Signal Temporal Logic (STL) is a formalism to express predicates on the values of signals. STL formulas consist of atomic predicates connected by Boolean and temporal operators. For example, the formula alw (temperature[t]<25) and ev_[0, 12] (humidity[t]>50) for the synthetic data above means that the temperature stays below 25 all day and that at some point in the morning (0 being midnight and 12 being noon), the humidity gets above 50 percents. A formula is constructed using STL_Formula objects, which takes a name and a string as constructor arguments:

>>  phi = STL_Formula('phi', 'alw (temperature[t]<25) and ev_[0, 12] (humidity[t]>50)')

Writing STL requirements in a file

STL formulas can be specified in a separate file, which makes it easier to create complex formulas using subformulas. Breach supports parameters also. The following illustrates rewriting the above formulas using Breach file format.

# File: Example_of_STL_spec_file.stl
# This is a comment. We define first parameters
param temp_threshold=25, humidity_threshold=50

# Atomic predicates are defined next
temp_is_ok       := temperature[t] < temp_threshold
humidity_is_high := humidity[t] > humidity_threshold

# Individual sub-formulas are defined next
temp_is_ok_all_day := alw (temp_is_ok)
humidity_is_high_before_noon := ev_[0, 12] (humidity_is_high)

# Final formula
phi := temp_is_ok_all_day and humidity_is_high_before_noon

To read an STL file, use the STL_ReadFile:

>> STL_ReadFile('Example_of_STL_spec_file.stl')

Using this command defines all formulas in the file and make them available as STL_Formula objects in the Matlab workspace.

Evaluating an STL formula on data

To evaluate an STL formula one needs to define a BreachRequirement object that can be constructed directly from an STL_Formula:

>> Rphi = BreachRequirement(phi);

A BreachRequirement object can store and combine more than one STL requirement or specification but this is its most common use. After creation, one can use the Eval method on data to check the satisfaction of its requirement.

>> Rphi.Eval(Bdata)

ans =

    0.4064

Note that the output is not a Boolean, but a real number. Breach computes so-called quantitative semantics, or robustness, of STL formulas. It can be interpreted as follows: if it is striclty positive, the formula is satisfied. If it is strictly negative, the formula is not satisfied by the data. When it is 0, it can be either way. The magnitude gives a hint of how "robustly" the formula is satisfied or violated. In this case, the number has a simple interpretation: the max temperature is about 24.6 Celsius degrees, i.e., about 0.4 degree below our threshold, which is the number we got.

Going further

For more information on specifications and how to use them, type this command into the Matlab prompt.

>> edit BrDemo.AFC_4_Specifications.m

and run the corresponding script.

Interfacing a Simulink model

Breach can act as a test harness for any Simulink model using the BreachSimulinkSystem class. To do so, one needs to decide which parameters Breach will be able to change before running a simulations and which signals will be monitored by Breach (these signals will be available for use in STL formulas).

Varying parameters

Varying parameters are most commonly those initialized in Matlab workspace before running Simulink. In the model itself, they reference the corresponding variable names. As a single example, consider the PI controller for the 'AbstractFuelControl' model (AFC in short, available in the Ext/Models folder) pictured below. The proportional gain and integral gain are using variables kp and ki.

AFC PI controller

These parameters are initialised in the InitAFCparams script, along with others used elsewhere.

fuel_inj_tol = 1.0; 
(...)
kp = 0.04;
ki = 0.14;

Note that if the model has some callback script run before each simulation, these scripts should not redefine the parameters interfaced with Breach.

Signals

Top level input and output signals

For a given Simulink model, input and output blocks are automatically monitored. In the AFC example from the diagram below, this means Breach will monitor input signals Pedal_Angle and Engine_Speed and output signals AF, AFref and controller_mode.

AFC model top level

Internal signals

In addition to input and output signals, internal lines marked for logging in a Simulink models as shown below are detected and monitored by Breach.

AFC model internal signals

Input signals generation

Once parameters and signals are defined, a BreachSimulinkSystem object can be created:

BrDemo.InitAFCparams % this ensures that parameters needed by Simulink are initialized in the workspace
Bsim = BreachSimulinkSystem('AbstractFuelControl');

By default input signals are assigned constant value determined by parameters names input_name_u0. E.g., in the AFC case, they are Engine_Speed_u0 and Pedal_Angle_u0. In Breach, there are many ways to assign input generator similar to what the signal builder in Simulink can do. The relevant method is SetInputGen. Two basic usages are:

  1. Constant time step input signals, using
Bsim.SetInputGen('UniStep3'); % creates 3 parameters for each input signals
  1. Variable time step input signals, using
Bsim.SetInputGen('VarStep3'); % creates 3 parameters for each input signals value and 10 time parameters

In this case, parameters are named input_name_u0,input_name_dt0, input_name_u1, input_name_dt1,..., where the timing parameter dt0 set the time difference between value u0 and u1. Many other options are available for signal generation. A GUI is available to explore some of them:

Bsim.SetInputGenGUI;

Input generator GUI

Going further

For more information type these command into the Matlab prompt

>> edit BrDemo.AFC_1_Interface.m
>> edit BrDemo.AFC_2_Simulation.m

and run the corresponding scripts.

Running and testing multiple simulations

To generate multiple simulations, one need to assign a range or domain of variation for some parameter(s)

BrDemo.InitAFC; %  Initialize the AFC model with a pulse generator for Pedal_Angle
var = {'Pedal_Angle_pulse_amp', 'Pedal_Angle_pulse_period'}; 
ranges = [ 10 60 ; 10 15] % ranges for pulse amplitude and pulse period
BrAFC.SetParamRanges(var, ranges); % declare ranges 

We can then sample this domain. The two most common methods for sampling are grid and quasi-random.

Bgrid = BrAFC.copy(); 
Bgrid.GridSample(5);  % creates a grid of 5x5=25 samples 

Brand = BrAFC.copy();
Brand.QuasiRandomSample(10);  % Creates 10 samples quasi-randomly in the specified range. 

Brand and Bgrid are now objects with multiple configurations for the AFC model. Using the Sim will run all of them and store the corresponding traces. E.g.,

Brand.Sim(40); % simulate AFC model until time 40
Brand.PlotSignals({'Pedal_Angle', 'AF'}); 

To test an STL requirement on 10 random simulations, we can simply eval it on Brand.

STL_ReadFile(AFC_simple_spec.stl)
R = BreachRequirement(AF_alw_ok);
R.Eval(Brand)

The Eval method evaluate the requirement for all 10 but returns a single value, by default the minimum over the 10 evaluations. The function BreachSamplesPlot can be used to examine the results in detail.

BreachSamplesPlot(R)

Going further

For more information on sampling sets, type the following command at the Matlab prompt

>> edit BrDemo.AFC_3_Sets.m

and run the corresponding script.

Falsification

Falsification is the process of letting an optimization algorithm run simulations searching for one that will violates a requirement. To setup a falsification run in Breach, one needs to

  1. create the interface and search space (e.g., a BreachSimulinkSystem object),
  2. create or choose the requirement (BreachRequirement object) and
  3. Create and setup a falsification problem (FalsificationProblem)

Steps 1. and 2. are the same as above when preparing for testing multiple traces.

% Step 1. create a BreachSimulinkSystem with variable parameters
BrDemo.InitAFC; % Initialize the AFC model with a pulse generator for Pedal_Angle
var = {'Pedal_Angle_pulse_amp', 'Pedal_Angle_pulse_period'}; 
ranges = [ 10 60 ; 10 15] % ranges for pulse amplitude and pulse period
BrAFC.SetParamRanges(var, ranges); 

% Step 2. Create a BreachRequirement object from an STL formula
STL_ReadFile(AFC_simple_spec.stl);
R = BreachRequirement(AF_alw_ok);

Step 3. is done directly by invoking the FalsificationProblem constructor:

pb = FalsificationProblem(BrAFC,R);

The problem is configured with default solver and options. Feeling adventurous, one can simply invoke the solve method to run falsification. Once it terminates, either after some time, or after finding a falsifying trace, results can be examined with the GetLog and BreachSamplesPlot functions.

pb.solve();
Rlog = pb.GetLog(); % returns a BreachRequirement object with evaluations of all traces computed during the falsification run
BreachSamplesPlot(Rlog); % interactive exploration of the run

Going further

For more information on falsification problems, solvers, etc, type the following command at the Matlab prompt

>> edit BrDemo.AFC_5_Falsification.m

and run the corresponding script.

Interfacing a generic simulator

For simulators other than Simulink, Breach offers a generic mechanism to create an interface. As an example, consider the code used to create artificial weather data above, slightly modified to include two parameters:

base_temp = 10; 
base_humidity = 50; 
time = 0:.1:24; % in hours
temperature = base_temp + 15*cos(pi*(time-3)/12+pi)+sin(pi/2*time); % in Celsius deg
humidity = base_humidity + 10*cos(pi*(time+2)/12)+sin(pi/3*time); % in percents

This is equivalent to having a (admitedly extremely simplified) weather simulator taking base temperature and humidity as parameters and returning temperature and humidity signals for one day. This code can be encapsulated in a function sim_weather and a Breach interface can be created with a BreachSystem object:

Bweather =  BreachSystem('weather', ...                 % system name 
                         {'temperature','humidity'},... % signals
                         {'base_temp','base_hum'},...   % parameters
                         [30 50], ...                   % default values for parameters
                         @sim_weather);

Then Bweather can be used to compute multiple traces varying parameters, monitor STL specifications, perform falsification, etc. Below is the complete, commented code for the sim_weather function:

function [t_out, X,p] = sim_weather(Sys, t_in, p) 
%  sim_weather computes one trace of the weather system, given a set of parameter vectors p
%  and a time specification t_in. 
%  
%  [t_out,X,p] = sim_weather(Sys,p,t_in) 
%  
%  Inputs: Sys, p and t_in are provided by Breach. 
%  - Sys is a structure with information about signals and parameters. In
%  particular,  Sys.ParamList is a cell of signals and parameter names such
%  that:
%     - Sys.ParamList(1:Sys.DimX) returns names of all signals
%     - Sys.ParamList(Sys.DimX+1:Sys.DimP) returns the names of constant parameters    
%  -  p is an array of length Sys.DimX+Sys.DimP. 
%  -  t_in is of the form [0 t_in(end)]  or [0 t_in(2) ... t_in(end)], strictly increasing
% 
%  Outputs:  simfn has to return the following:    
%      - t_out must be such that t_out(1) =0 and t_out(end) = t_in(end). 
%        In addition, if t_in has more than two elements, then t_out must be
%        equal to t_in. Otherwise, t_out can have as many elements as
%        returned by the simulation.
%     - X must be of dimensions (Sys.DimX, t_out). The rows of X must
%     contain simulation results for signals named in Sys.ParamList(1:DimX)
%    -  p is the same as p unless the simulator changes it (outputs scalars
%           in addition to signals)

% recover parameters from p - for legacy reason, the first elements in p
% are for signals, and parameters start at index Sys.DimX+1 = 3
base_temp =p(3);
base_hum = p(4); 

% compute signals - a simple function of time in this case but for a more complex 
% simulator, this is where the actual call to the simulator will take place
temperature = base_temp + 15*cos(pi*(t_in-3)/12+pi)+sin(pi/2*t_in); % in Celsius deg
humidity = base_hum + 10*cos(pi*(t_in+2)/12)+sin(pi/3*t_in); % in percents

% format outputs as expected by Breach
X = [temperature;     
     humidity]; 
t_out = t_in;             

end