"type": "object",
"properties": {
"content-spec": {
"type": "string",
"default": "urn:spec://eclipse.org/unide/measurement-message#v2",
"description": "Defines what the format version is"
},
"device": {
"type": "object",
"description": "Contains information about the device",
"properties": {
"deviceID": {
"type": "string",
"description": "The unique ID of the device. As this is used to identify a device independently from time or location the ID itself must be stable and unique. The recommendation is to use a universally unique identifier (UUID).",
"maxLength": 36
},
"metaData": {
"type": "object",
"patternProperties": {
".*": {
"type": "string"
}
},
"additionalProperties": false,
"description": "Additional key-value pairs in a JSON structure format. Key and value must be strings"
},
"operationalStatus": {
"type": "string",
"description": "The operationalStatus describes the status of a device. It is a string matching a definition in the Production Performance Manager"
}
},
"additionalProperties": false,
"required": [
"deviceID"
]
},
"part": {
"type": "object",
"properties": {
"code": {
"type": "string",
"description": "The code is an addendum to the result which allows to pass information in the case the result was NOK. The value often stems from the integrated system e.g. a PLC code",
"maxLength": 36
},
"metaData": {
"type": "object",
"patternProperties": {
".*": {
"type": "string"
}
},
"additionalProperties": false,
"description": "Additional key-value pairs in a JSON structure format. Key and value must be strings"
},
"partID": {
"type": "string",
"description": "Identifies a part. This ID comes from a 3rd party system and thus we have no guarantees if this is unique or not.",
"maxLength": 256
},
"partTypeID": {
"type": "string",
"description": "Identifies a part type",
"maxLength": 256
},
"result": {
"type": "string",
"enum": [
"OK",
"NOK",
"UNKNOWN"
],
"description": "Information if the result was ok or not. This is only required if part information should be saved.",
"default": "UNKNOWN"
}
},
"additionalProperties": false,
"required": []
},
"measurements": {
"type": "array",
"minItems": 1,
"items": {
"type": "object",
"properties": {
"code": {
"type": "string",
"description": "The code is an addendum to the result which allows to pass information in the case the result was NOK. The value often stems from the integrated system e.g. a PLC code",
"maxLength": 36
},
"limits": {
"type": "object",
"description": "Provides information about limits for data provided in the series element.",
"patternProperties": {
"^[^$]+": {
"type": "object",
"description": "The key shall be the name of a measurement point (element of series element). The value is a structure of different upper/lower limits.",
"properties": {
"lowerError": {
"type": "number",
"description": "Indicates an error if this limit is underrun"
},
"lowerWarn": {
"type": "number",
"description": "Indicates a warning if this limit is underrun"
},
"target": {
"type": "number",
"description": "Indicates the intented target value of the measurement"
},
"upperError": {
"type": "number",
"description": "Indicates an error if this limit is exceeded"
},
"upperWarn": {
"type": "number",
"description": "Indicates a warning if this limit is exceeded"
}
}
}
},
"additionalProperties": false,
"required": []
},
"result": {
"type": "string",
"enum": [
"OK",
"NOK",
"UNKNOWN"
],
"description": "Information if the result was ok or not. This is only required if part information should be saved.",
"default": "UNKNOWN"
},
"series": {
"type": "object",
"description": "The series data collected for the measurements. Every entry matches a Measurement Point of the Device Type. In the case of a time series, one column contains the time offsets.",
"properties": {
"$_time": {
"type": "array",
"description": "The time offset in milliseconds (positive values in ascending order starting with 0) to the 'ts' field of the measurement",
"items": {
"type": "integer"
}
}
},
"patternProperties": {
"^[^$]+": {
"type": "array",
"items": {
"type": "number"
}
}
},
"required": [
"$_time"
],
"minProperties": 2,
"additionalProperties": false
},
"ts": {
"format": "date-time",
"type": "string",
"description": "Start time of the the data measurment in ISO 8601 format"
}
},
"required": [
"ts",
"series"
]
}
}
},
"additionalProperties": false,
"required": [
"content-spec",
"device",
"measurements"
]
}