We just found out that because rotational_minctracc.py uses the default value for the simplex (20mm), this stage fails fairly often at SciNet. There is still the question why when the same command run at MICe we don't have this issue, but scaling the -simplex value to something reasonable (1mm), fixes the issue at SciNet.
The text was updated successfully, but these errors were encountered:
We just found out that because rotational_minctracc.py uses the default value for the simplex (20mm), this stage fails fairly often at SciNet. There is still the question why when the same command run at MICe we don't have this issue, but scaling the -simplex value to something reasonable (1mm), fixes the issue at SciNet.