diff --git a/src/ontology/components/vibso_classes.owl b/src/ontology/components/vibso_classes.owl index 3f93ba2..01e0a1d 100644 --- a/src/ontology/components/vibso_classes.owl +++ b/src/ontology/components/vibso_classes.owl @@ -24,8 +24,8 @@ Prefix(Wikipedia:=) Ontology( - -Annotation(rdfs:comment "This component is derived from the manually edited 'src/templates/vibso_classes.tsv' template.") + +Annotation(rdfs:comment "This component is derived from the 'src/templates/vibso_classes.tsv', which is edited manually by domain experts.") Declaration(Class(obo:BFO_0000029)) Declaration(Class(obo:IAO_0000027)) @@ -38,6 +38,7 @@ Declaration(Class(obo:OBI_0001933)) Declaration(Class(obo:OBI_0200000)) Declaration(Class(obo:OBI_0200181)) Declaration(Class(obo:PATO_0001018)) +Declaration(Class(obo:PATO_0001293)) Declaration(Class(obo:STATO_0000184)) Declaration(Class(obo:VIBSO_0000000)) Declaration(Class(obo:VIBSO_0000001)) @@ -70,6 +71,7 @@ Declaration(Class(obo:VIBSO_0000027)) Declaration(Class(obo:VIBSO_0000028)) Declaration(Class(obo:VIBSO_0000029)) Declaration(Class(obo:VIBSO_0000030)) +Declaration(ObjectProperty(obo:BFO_0000050)) Declaration(Class(obo:VIBSO_0000031)) Declaration(Class(obo:VIBSO_0000032)) Declaration(Class(obo:VIBSO_0000033)) @@ -85,6 +87,7 @@ Declaration(Class(obo:VIBSO_0000042)) Declaration(Class(obo:VIBSO_0000043)) Declaration(Class(obo:VIBSO_0000044)) Declaration(Class(obo:VIBSO_0000045)) +Declaration(Class(obo:VIBSO_0000051)) Declaration(Class(obo:VIBSO_0003017)) Declaration(ObjectProperty(obo:IAO_0000136)) Declaration(ObjectProperty(obo:OBI_0000293)) @@ -421,6 +424,9 @@ AnnotationAssertion(rdfs:label obo:VIBSO_0000027 "number of measurements Z"@en) AnnotationAssertion(rdfs:seeAlso obo:VIBSO_0000027 ) SubClassOf(obo:VIBSO_0000027 obo:IAO_0000140) + +# Class: obo:VIBSO_0000028 (absorbance) + # Class: obo:VIBSO_0000028 (Raman raw data) AnnotationAssertion(Annotation(dc:source ) obo:IAO_0000115 obo:VIBSO_0000028 "A measurement datum that is obtained from a calibrated and ready Raman spectrometer and prior to be submitted to any mathematical modification. The only corrections on the data shall be the one associated with the spectrometer. The data will assign pixels readouts with nm as per calibration of the spectrometer and a.u. as intensity readout but will not be corrected in relationship of the incident monochromatic beam."@en) @@ -452,6 +458,14 @@ AnnotationAssertion(rdfs:seeAlso obo:VIBSO_0000030 ) Annotation(dc:source ) Annotation(dc:source Wikipedia:Absorbance) obo:IAO_0000115 obo:VIBSO_0000028 "A data item that quantifies the absorption of light by some material as the logarithm of the incident electromagnetic radiation power (before absorption), divided by the transmitted electromagnetic radiation power (after absorption)."@en) +AnnotationAssertion(dc:contributor obo:VIBSO_0000028 ) +AnnotationAssertion(rdfs:comment obo:VIBSO_0000028 "Definition was adapted from “afo:absorbance“. We did not reuse/import this AFO term directly due to the associated ontological commitment of AFO. Yet, we will provide a mapping."@en) +AnnotationAssertion(rdfs:label obo:VIBSO_0000028 "absorbance"@en) +AnnotationAssertion(rdfs:seeAlso obo:VIBSO_0000028 ) +SubClassOf(obo:VIBSO_0000028 obo:IAO_0000027) +SubClassOf(obo:VIBSO_0000028 ObjectSomeValuesFrom(obo:IAO_0000136 obo:PATO_0001293)) + # Class: obo:VIBSO_0000031 (resolution) AnnotationAssertion(obo:IAO_0000115 obo:VIBSO_0000031 "A physical quality of a measurement device that expresses (realizes) the device's capacity to distinguish between two distinct but closely related measurements of the same physical quality or type, often quantified as the smallest detectable difference (resolution interval) between measured values."@en) @@ -624,5 +638,4 @@ AnnotationAssertion(rdfs:seeAlso obo:VIBSO_0003017 ) Ontology( - -Annotation(rdfs:comment "This component is derived from the manually edited 'src/templates/vibso_object_properties.tsv' template.") - - - -) \ No newline at end of file + +Annotation(rdfs:comment "This component is derived from the 'src/templates/vibso_object_properties.tsv', which is edited manually by domain experts.") +) diff --git a/src/templates/vibso_classes.tsv b/src/templates/vibso_classes.tsv index d06a0f6..b8cb030 100644 --- a/src/templates/vibso_classes.tsv +++ b/src/templates/vibso_classes.tsv @@ -2,7 +2,7 @@ id label alternative term super class definition definition source URI comment e ID AL rdfs:label@en AL IAO:0000118@en SPLIT=| SC % SPLIT=| AL IAO:0000115@en >AI dc11:source SPLIT=| AL rdfs:comment@en SPLIT=| AL IAO:0000112@en AL IAO:0000116@en SPLIT=| AT owl:deprecated^^xsd:boolean AI IAO:0000231 AI IAO:0100001 AI dc11:contributor SPLIT=| AI rdfs:seeAlso SPLIT=| TYPE obo:VIBSO_0000000 vibrational spectrometer configuration specification setting datum A setting datum that specifies the needed settings of a spectrometer used in vibrational spectroscopy. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/39 owl:Class obo:VIBSO_0000001 Raman spectrometer configuration device setting A device setting that represents the measured or set physical qualities which make up the configuration state of a Raman spectrometer at the time of a measurement (e.g. operating temperature, exitation wavelength, groove density, ...). The set of meassured configuration characteristics of a Raman spectrometer, like the operating temperature of a Raman spectrometer. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/47 owl:Class -obo:VIBSO_0000002 integration time setting integration time|integration period setting setting datum A setting datum that specifies the length of time that a photo detector is allowed to collect photons before passing the accumulated charge to the A/D converter for processing. The minimum integration time is the shortest integration time the device supports and is dependent on how fast the detector can read out all of the pixel information. Integration time should not be confused with data transfer speed. https://www.oceaninsight.com/knowledge-hub/glossary/#i This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/40 owl:Class +obo:VIBSO_0000002 integration time setting integration period setting setting datum A setting datum that specifies the length of time that a photo detector is allowed to collect photons before passing the accumulated charge to the A/D converter for processing. The minimum integration time is the shortest integration time the device supports and is dependent on how fast the detector can read out all of the pixel information. Integration time should not be confused with data transfer speed. https://www.oceaninsight.com/knowledge-hub/glossary/#i This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/40 owl:Class obo:VIBSO_0000003 preamplifier gain setting setting datum A setting datum that specifies the preamplifier gain in CCD sensors. This class should better be defined in a more general device ontology. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/41 owl:Class obo:VIBSO_0000004 horizontal shift speed setting setting datum A setting datum that specifies the horizontal shift speed in CCD sensors. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/42 owl:Class obo:VIBSO_0000005 vertical shift speed setting setting datum A setting datum that specifies the vertical shift speed in CCD sensors. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/42 owl:Class @@ -10,13 +10,13 @@ obo:VIBSO_0000006 device temperature setting setting datum A setting datum that obo:VIBSO_0000007 number of accumulations number of acquisitions setting datum A setting datum that specifies the desired number of measurements a spectrometer has to perform on the same location, without position change to produce an usable spectrum. This setting datum is relevant to improve the signal to noise ratio. This class might better be defined in a more general device ontology. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/30 owl:Class obo:VIBSO_0000008 CCD sensor binning read mode setting setting datum A setting datum that specifies the binning read mode of a device with a CCD sensor. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/46 owl:Class obo:VIBSO_0000009 groove density groove frequency physical quality A physical quality inhering in a diffraction grating device by virtue of the device's function to diffract light. This quality specifically depends on the number of grooves per area of the grating device and is usually expressed in grooves per millimeter. Wikipedia:Diffraction_grating|https://www.meetoptics.com/academy/groove-density#:~:text=The%20groove%20density%20(or%20groove,of%20the%20operational%20wavelength%20range temp class until NTR in PATO has been accepted and merged (https://github.com/pato-ontology/pato/issues/541) ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/45 owl:Class -obo:VIBSO_0000010 groove density setting grating|grating setting setting datum A setting datum that specifies the number of grooves in a diffraction grating device. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/45 owl:Class +obo:VIBSO_0000010 groove density setting setting datum A setting datum that specifies the number of grooves in a diffraction grating device. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/45 owl:Class obo:VIBSO_0000011 diffraction grating device A device that is an optical component with a periodic structure that diffracts light into several beams travelling in different directions (i.e. different diffraction angles) https://en.wikipedia.org/wiki/Diffraction_grating This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/49 owl:Class obo:VIBSO_0000012 deprecated_excitation wavelength A physical quality of the light source that is used used to excite a system to a higher energy state. This class is not needed, as PATO:wavelength is sufficient, if this quality of a Raman device is really needed. true failed exploratory term wavelength ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/48 owl:Class obo:VIBSO_0000013 excitation wavelength setting setting datum A setting datum that specifies the wavelength of an electromagnetic radiation source (e.g. a laser) which has the function to excite the energy state of a target material. This class should better be defined in a more general device ontology or a domain ontology with the scope of optical devices. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/48 owl:Class obo:VIBSO_0000014 objective magnification factor setting magnification|magnification setting setting datum A setting datum that specifies the magnification factor of the objective collecting the scattered light. 100x ORCID:0000-0002-1595-3213|ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/24 owl:Class -obo:VIBSO_0000015 spectral window range maximum acquisition band maximum setting datum A setting datum that specifies the upper boundary of the spectral window range utilized during the acquisition of spectroscopic data. 210 cm^-1 It needs to be determined, if this is also part of another kind of spectrum, such as a vibrational spectrum in general. We also need to decide, if we need to also model the terms window size and window center, from which this term is derived. ORCID:0000-0002-1595-3213|ORCID:0000-0001-7694-5519 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/31 owl:Class -obo:VIBSO_0000016 spectral window range minimum acquisition band minimum setting datum A setting datum that specifies the lower boundary of the spectral window range utilized during the acquisition of spectroscopic data. 1960 cm^-1 It needs to be determined, if this is also part of another kind of spectrum, such as a vibrational spectrum in general. We also need to decide, if we need to also model the terms window size and window center, from which this term is derived. ORCID:0000-0002-1595-3213|ORCID:0000-0001-7694-5519 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/31 owl:Class +obo:VIBSO_0000015 spectral window range maximum acquisition band maximum data item|('part of' some 'Raman spectrum') A data item that is the part of a Raman spectrum which represents the maximum wavenumber included in the spectrum and which is calculated from the windows size and window center. 210 cm^-1 It needs to be determined, if this is also part of another kind of spectrum, such as a vibrational spectrum in general. We also need to decide, if we need to also model the terms window size and window center, from which this term is derived. ORCID:0000-0002-1595-3213|ORCID:0000-0001-7694-5519 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/31 owl:Class +obo:VIBSO_0000016 spectral window range minimum acquisition band minimum data item|('part of' some 'Raman spectrum') A data item that is the part of a Raman spectrum which represents the minimum wavenumber included in the spectrum and which is calculated from the windows size and window center. 1960 cm^-1 It needs to be determined, if this is also part of another kind of spectrum, such as a vibrational spectrum in general. We also need to decide, if we need to also model the terms window size and window center, from which this term is derived. ORCID:0000-0002-1595-3213|ORCID:0000-0001-7694-5519 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/31 owl:Class obo:VIBSO_0000017 incident light power datum excitation light power|light power on the sample scalar measurement datum A scalar measurement datum that is the result of measuring the incoming light power before the sample holder and which depends on the laser power and on the dispersive behaviour of the filters and optical components. The incident power is an elementary measurement parameter allowing to compare among measurements conducted with the same setup. A thorough investigation of the effects of light irradiation onto the sample depends on the local irradiance (power per unit area) and requires deeper knowledge of the irradiation geometry, e.g. width, depth and shape of the focal spot. 200 mW ORCID:0000-0001-7694-5519 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/29 owl:Class obo:VIBSO_0000018 region of interest imaging region of interest|ROI site A site that refers to a user-defined portion of the image area in which data will be acquired. The remainder of the image area will be discarded. https://wiki.charisma.ideaconsult.net/wiki/Item:Q57 See also https://w3id.org/reproduceme#ROI & http://purl.obolibrary.org/obo/NCIT_C85402 ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class obo:VIBSO_0000019 region of interest width ROI width|ROI horizontal length setting datum A setting datum that specifies the width (length in the X direction) of the region of interest. region of interest width = (point distance X) * (number of measurements X) 1 mm ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class @@ -26,7 +26,7 @@ obo:VIBSO_0000022 point distance X sampling pace in the X direction|sampling ste obo:VIBSO_0000023 point distance Y sampling pace in the Y direction|sampling step in the Y direction|voxel distance in the Y direction setting datum A setting datum that specifies the equal distance which the incident light beam will be moved laterally in the Y direction on a given sample within the region of interest after each measurement, when performing a spatially resolved spectroscopy. point distance Y = (region of interest breadth) / (number of measurements Y) 10 µm ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class obo:VIBSO_0000024 point distance Z sampling pace in the Z direction|sampling step in the Z direction|voxel distance in the Z direction|vertical mapping distance|axial mapping distance setting datum A setting datum that specifies the equal distance which the incident light beam will moved along the focal axis within the region of interest, when performing a spatially resolved spectroscopy. point distance Z = (region of interest depth) / (number of measurements Z) 10 µm ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class obo:VIBSO_0000025 number of measurements X number of points in the X direction|number of points per line setting datum A setting datum that specifies how many equally configured measurements of a sample are to be performed along the X-axis of a certain region of interest. Together with the point distance X, this setting defines the region of interest width. number of measurements X = (region of interest width) / (point distance X) 50 ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class -obo:VIBSO_0000026 number of measurements Y number of points in the Y direction|number of lines per layer setting datum A setting datum that specifies how many equally configured measurements of a sample are to be performed along the Y-axis of a certain region of interest. Together with the point distance Y, this setting defines the region of interest breadth. number of measurements = (region of interest breadth) / (point distance Y) 100 ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class +obo:VIBSO_0000026 number of measurements Y number of points in the Y direction|number of lines per layer setting datum A setting datum that specifies how many equally configured measurements of a sample are to be performed along the Y-axis of a certain region of interest. Together with the point distance Y, this setting defines the region of interest breadth. number of measurements Y = (region of interest breadth) / (point distance Y) 100 ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class obo:VIBSO_0000027 number of measurements Z number of points in the Z direction|number of layers per acquisition setting datum A setting datum that specifies how many equally configured measurements of a sample are to be performed in the vertical direction (on the Z-axis) of a certain region of interest. Together with the focal point distance, this setting defines the region of interest depth. number of measurements Z = (region of interest depth) / (point distance Z) 10 ORCID:0000-0001-7694-5519|ORCID:0000-0002-2239-3956 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/32 owl:Class obo:VIBSO_0000028 Raman raw data raw Raman data measurement datum A measurement datum that is obtained from a calibrated and ready Raman spectrometer and prior to be submitted to any mathematical modification. The only corrections on the data shall be the one associated with the spectrometer. The data will assign pixels readouts with nm as per calibration of the spectrometer and a.u. as intensity readout but will not be corrected in relationship of the incident monochromatic beam. https://wiki.charisma.ideaconsult.net/wiki/Item:Q64 ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/77 owl:Class obo:VIBSO_0000029 lens numerical aperture numerical aperture setting datum A setting datum that, as a dimensionless number, represents the quality which characterizes the range of angles over which an optical system can accept or emit light [dc:source wikidata:Numerical_aperture]. It gets calculated by the sine of one half of the vertex angle of the largest cone of meridional rays that can enter or leave an optical system or element, multiplied by the refractive index of the medium in which the cone is located. https://wiki.charisma.ideaconsult.net/wiki/Item:Q385|https://en.wikipedia.org/wiki/Numerical_aperture The light was focused onto the embedded sample using a 100× objective with a numerical aperture of 0.9, resulting in a diffraction-limited in-plane laser spot size of <1 μm. possible equivalents in other terminologies: http://purl.obolibrary.org/obo/NCIT_C181921 & https://w3id.org/reproduceme#LensNA ORCID:0000-0002-1595-3213|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/76 owl:Class @@ -46,4 +46,5 @@ obo:VIBSO_0000042 spectral resolution interval as energy spectral resolution in obo:VIBSO_0000043 radiometric resolution interval resolution interval A resolution interval that quantifies the minimum difference in irradiated energy, often coded as gray level in a grayscale or look-up-table (LUT). ISBN 081946043-5 This class is actually to general for VIBSO's scope. It needs to be discussed with CHMO and OBI devs which of these is a better home, as there currently does not exist an optical device ontology within OBO Foundry. OBI contains most terms around optical devices so far. ORCID:0000-0003-2673-366X|ORCID:0000-0003-2673-366X|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/125 owl:Class obo:VIBSO_0000044 temporal resolution interval resolution interval A resolution interval that quantifies the temporal separation between two measurements or frames, often expressed as the inverse of the frame rate. In techniques where temporal resolution is not directly derived from frame rate, it quantifies the minimum temporal interval between two resolvable events. ISBN 081946043-5 In techniques where the temporal resolution is not given directly from a temporal distance between subsequent measurements (e.g., pulsed time resolved pump-probe techniques), it can be used more properly as defined above This class is actually to general for VIBSO's scope. It needs to be discussed with CHMO and OBI devs which of these is a better home, as there currently does not exist an optical device ontology within OBO Foundry. OBI contains most terms around optical devices so far. ORCID:0000-0003-2673-366X|ORCID:0000-0003-2673-366X|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/125 owl:Class obo:VIBSO_0000045 diffraction limit spatial resolution interval A spatial resolution interval that quantifies the theoretical maximum spatial resolution achievable by an optical system, constrained by the diffraction of light. ISO/DIS 18115-3, https://www.iso.org/obp/ui#d25805417e256 The Abbe diffraction limit, is defined as λ/ (2 NA) in which λ is the wavelength of the illuminating light and NA is the numerical aperture. This class is actually to general for VIBSO's scope. It needs to be discussed with CHMO and OBI devs which of these is a better home, as there currently does not exist an optical device ontology within OBO Foundry. OBI contains most terms around optical devices so far. ORCID:0000-0003-2673-366X|ORCID:0000-0003-2673-366X|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/125 owl:Class +obo:VIBSO_0000051 absorbance extinction data item|('is about' some obo:PATO_0001293) A data item that quantifies the absorption of light by some material as the logarithm of the incident electromagnetic radiation power (before absorption), divided by the transmitted electromagnetic radiation power (after absorption). https://doi.org/10.1351/goldbook|http://purl.allotrope.org/ontologies/result#AFR_0001157|https://en.wikipedia.org/wiki/Absorbance Definition was adapted from “afo:absorbance“. We did not reuse/import this AFO term directly due to the associated ontological commitment of AFO. Yet, we will provide a mapping. ORCID:0000-0002-1595-3213 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/86 owl:Class obo:VIBSO_0003017 spectral window center setting datum|'is_specified_output_of' some 'center calculation data transformation' A setting datum that specifies the middle wavelength/wavenumber of a spectrum, equal to the average of the maximum and minimum of the spectral window range utilized during the acquisition of spectroscopic data. It corresponds to the optimal alignment or centering of the spectrometer to ensure that the most relevant spectral features are captured effectively within the defined acquisition range. 560 cm^-1 ORCID:0000-0002-1595-3213|ORCID:0000-0002-2239-3955 https://github.com/NFDI4Chem/VibrationalSpectroscopyOntology/issues/88 owl:Class