diff --git a/testfiles/US+SF+CZ4A+hp+crawlspace+IECC_2006_VRF.idf b/testfiles/US+SF+CZ4A+hp+crawlspace+IECC_2006_VRF.idf index 5dc92cae8bf..0cfc1a863de 100644 --- a/testfiles/US+SF+CZ4A+hp+crawlspace+IECC_2006_VRF.idf +++ b/testfiles/US+SF+CZ4A+hp+crawlspace+IECC_2006_VRF.idf @@ -4607,104 +4607,6 @@ 15, !- CLEARANCE: Distance from edge of slab to domain edge {m} 15; !- ZCLEARANCE: Distance from bottom of slab to domain bottom {m} -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:SIMPARAMETERS =========== - - GroundHeatTransfer:Basement:SimParameters, - 0.1, !- F: Multiplier for the ADI solution - 15; !- IYRS: Maximum number of yearly iterations: - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:MATLPROPS =========== - - GroundHeatTransfer:Basement:MatlProps, - 6, !- NMAT: Number of materials in this domain - 2243, !- Density for Foundation Wall {kg/m3} - 2243, !- density for Floor Slab {kg/m3} - 311, !- density for Ceiling {kg/m3} - 1500, !- density for Soil {kg/m3} - 2000, !- density for Gravel {kg/m3} - 449, !- density for Wood {kg/m3} - 880, !- Specific heat for foundation wall {J/kg-K} - 880, !- Specific heat for floor slab {J/kg-K} - 1530, !- Specific heat for ceiling {J/kg-K} - 840, !- Specific heat for soil {J/kg-K} - 720, !- Specific heat for gravel {J/kg-K} - 1530, !- Specific heat for wood {J/kg-K} - 1.4, !- Thermal conductivity for foundation wall {W/m-K} - 1.4, !- Thermal conductivity for floor slab {W/m-K} - 0.09, !- Thermal conductivity for ceiling {W/m-K} - 1.1, !- thermal conductivity for soil {W/m-K} - 1.9, !- thermal conductivity for gravel {W/m-K} - 0.12; !- thermal conductivity for wood {W/m-K} - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:INSULATION =========== -!- $r_bsmtwall_SI = $r_bsmtwall/5.6786; -!- 0.0001; - - GroundHeatTransfer:Basement:Insulation, - 1.76099742894375e-05, !- REXT: R Value of any exterior insulation {m2-K/W} - True; !- INSFULL: Flag: Is the wall fully insulated? - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:SURFACEPROPS =========== - - GroundHeatTransfer:Basement:SurfaceProps, - 0.16, !- ALBEDO: Surface albedo for No snow conditions - 0.4, !- ALBEDO: Surface albedo for snow conditions - 0.94, !- EPSLN: Surface emissivity No Snow - 0.86, !- EPSLN: Surface emissivity with Snow - 6, !- VEGHT: Surface roughness No snow conditions {cm} - 0.25, !- VEGHT: Surface roughness Snow conditions {cm} - False; !- PET: Flag, Potential evapotranspiration on? - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:BLDGDATA =========== - - GroundHeatTransfer:Basement:BldgData, - 0.200000006162114, !- DWALL: Wall thickness {m} - 0.243828108701145, !- DSLAB: Floor slab thickness {m} - 0.3, !- DGRAVXY: Width of gravel pit beside basement wall {m} - 0.2, !- DGRAVZN: Gravel depth extending above the floor slab {m} - 0.1; !- DGRAVZP: Gravel depth below the floor slab {m} - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:INTERIOR =========== - - GroundHeatTransfer:Basement:Interior, - True, !- COND: Flag: Is the basement conditioned? - 0.92, !- HIN: Downward convection only heat transfer coefficient {W/m2-K} - 4.04, !- HIN: Upward convection only heat transfer coefficient {W/m2-K} - 3.08, !- HIN: Horizontal convection only heat transfer coefficient {W/m2-K} - 6.13, !- HIN: Downward combined (convection and radiation) heat transfer coefficient {W/m2-K} - 9.26, !- HIN: Upward combined (convection and radiation) heat transfer coefficient {W/m2-K} - 8.29; !- HIN: Horizontal combined (convection and radiation) heat transfer coefficient {W/m2-K} - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:COMBLDG =========== - - GroundHeatTransfer:Basement:ComBldg, - 21, !- January average temperature {C} - 21, !- February average temperature {C} - 21, !- March average temperature {C} - 21, !- April average temperature {C} - 24, !- May average temperature {C} - 24, !- June average temperature {C} - 24, !- July average temperature {C} - 24, !- August average temperature {C} - 24, !- September average temperature {C} - 24, !- October average temperature {C} - 21, !- November average temperature {C} - 21, !- December average temperature {C} - 21; !- Daily variation sine wave amplitude {deltaC} - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:EQUIVSLAB =========== - - GroundHeatTransfer:Basement:EquivSlab, - 2.59994805991784, !- APRatio: The area to perimeter ratio for this slab {m} - True; !- EquivSizing: Flag - -!- =========== ALL OBJECTS IN CLASS: GROUNDHEATTRANSFER:BASEMENT:EQUIVAUTOGRID =========== - - GroundHeatTransfer:Basement:EquivAutoGrid, - 15, !- CLEARANCE: Distance from outside of wall to edge of 3-D ground domain {m} - 0.1, !- SlabDepth: Thickness of the floor slab {m} - 1.21914054350572; !- BaseDepth: Depth of the basement wall below grade {m} - !- Process internal gains from the appliances.template.. ElectricEquipment,