Skip to content

Linking static library with device functions depends on argument order #77

Open
@Snektron

Description

@Snektron

After creating a static library containing device functions using -fgpu-rdc and ar, the library is linked with a command like:

hipcc libdevicelibrary.a main.cpp -fgpu-rdc -o program

This works fine, however, when the argument order is reversed and main.cpp is passed before libdevicelibrary.a, the compiler tries to interpret the files from libdevicelibrary.a as source file:

$ hipcc main.cpp libdevicelibrary.a -fgpu-rdc -o program
/tmp/library.o:1:1: error: expected unqualified-id
<U+007F>ELF<U+0002><U+0001><U+0001><U+0000>.... many more lines

This is caused by that placing main.cpp on the command line causes hipcc to emit -x hip before it, which causes clang++ to interpret library.o as a .hip source file:

$ HIPCC_VERBOSE=1 hipcc main.cpp libdevicelibrary.a -fgpu-rdc -o program
hipcc-cmd: /opt/rocm/llvm/bin/clang++ [...extra options omitted for brevity] -x hip main.hip """/tmp/library.o""" -std=c++17 -fgpu-rdc -o "program" 