See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -4.7dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -4.8 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 76 Hz | 0.32 | -3.3 dB |
Peaking | 3112 Hz | 4.31 | 3.8 dB |
Peaking | 3927 Hz | 3.78 | 3.1 dB |
Peaking | 6705 Hz | 4.18 | 3.8 dB |
Peaking | 9130 Hz | 3.74 | 2.9 dB |
Peaking | 241 Hz | 2.37 | 1.0 dB |
Peaking | 508 Hz | 2.13 | -1.1 dB |
Peaking | 1715 Hz | 3.8 | -1.4 dB |
Peaking | 11307 Hz | 1.03 | 3.8 dB |
Peaking | 19774 Hz | 0.35 | -13.8 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -3.8dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | -1.9 dB |
Peaking | 62 Hz | 1.41 | -2.7 dB |
Peaking | 125 Hz | 1.41 | -3.0 dB |
Peaking | 250 Hz | 1.41 | -0.1 dB |
Peaking | 500 Hz | 1.41 | -1.7 dB |
Peaking | 1000 Hz | 1.41 | 0.5 dB |
Peaking | 2000 Hz | 1.41 | -1.0 dB |
Peaking | 4000 Hz | 1.41 | 3.4 dB |
Peaking | 8000 Hz | 1.41 | 3.7 dB |
Peaking | 16000 Hz | 1.41 | -10.2 dB |