diff --git a/mpet/mod_cell.py b/mpet/mod_cell.py index bec77c84..38653fbe 100644 --- a/mpet/mod_cell.py +++ b/mpet/mod_cell.py @@ -118,6 +118,10 @@ def __init__(self, config, Name, Parent=None, Description=""): self.c_lyteGP_L = dae.daeVariable("c_lyteGP_L", conc_t, self, "c_lyte left BC GP") self.phi_lyteGP_L = dae.daeVariable( "phi_lyteGP_L", elec_pot_t, self, "phi_lyte left BC GP") + self.T_lyteGP_L = dae.daeVariable( + "T_lyteGP_L", temp_t, self, "T_lyte left BC GP") + self.T_lyteGP_R = dae.daeVariable( + "T_lyteGP_R", temp_t, self, "T_lyte left BC GP") self.phi_applied = dae.daeVariable( "phi_applied", elec_pot_t, self, "Overall battery voltage (at anode current collector)") @@ -338,7 +342,7 @@ def DeclareEquations(self): # Ghost points on the left and no-gradients on the right ctmp = np.hstack((self.c_lyteGP_L(), cvec, cvec[-1])) # temperature uses a constant boundary condition - Ttmp = np.hstack((config["T"], Tvec, config["T"])) + Ttmp = np.hstack((self.T_lyteGP_L(), Tvec, self.T_lyteGP_R())) phitmp = np.hstack((self.phi_lyteGP_L(), phivec, phivec[-1])) Nm_edges, i_edges, q_edges = get_lyte_internal_fluxes(ctmp, phitmp, Ttmp, disc, @@ -377,6 +381,12 @@ def DeclareEquations(self): eqC.Residual = ctmp[0] - ctmp[1] eqP.Residual = phitmp[0] - phitmp[1] + # boundary equation for temperature variables. per volume + eqTL = self.CreateEquation("GhostPointT_L") + eqTR = self.CreateEquation("GhostPointT_R") + eqTL.Residual = Ttmp[0] - config["T"] + eqTR.Residual = Ttmp[-1] - config["T"] + dvgNm = np.diff(Nm_edges)/disc["dxvec"] dvgi = np.diff(i_edges)/disc["dxvec"] dvgq = np.diff(q_edges)/disc["dxvec"] @@ -551,8 +561,9 @@ def get_lyte_internal_fluxes(c_lyte, phi_lyte, T_lyte, disc, config, Nvol): Dm = eps_o_tau_edges * config["Dm"] Nm_edges_int = num*(-Dm*np.diff(c_lyte)/dxd1 - Dm/T_edges_int*zm*c_edges_int*np.diff(phi_lyte)/dxd1) - i_edges_int = (-((nup*zp*Dp + num*zm*Dm)*np.diff(c_lyte)/dxd1) - (nup*zp - ** 2*Dp + num*zm**2*Dm)/T_edges_int*c_edges_int*np.diff(phi_lyte)/dxd1) + i_edges_int = (-((nup*zp*Dp + num*zm*Dm)*np.diff(c_lyte)/dxd1) + - (nup*zp**2*Dp + num*zm**2*Dm)/T_edges_int + *c_edges_int*np.diff(phi_lyte)/dxd1) elif config["elyteModelType"] == "SM": SMset = config["SMset"] elyte_function = utils.import_function(config["SMset_filename"], SMset, diff --git a/mpet/sim.py b/mpet/sim.py index bdc3b075..9fc31eed 100644 --- a/mpet/sim.py +++ b/mpet/sim.py @@ -118,6 +118,8 @@ def SetUpVariables(self): if not self.m.SVsim: self.m.c_lyteGP_L.SetInitialGuess(config["c0"]) self.m.phi_lyteGP_L.SetInitialGuess(0) + self.m.T_lyteGP_L.SetInitialGuess(config["T"]) + self.m.T_lyteGP_R.SetInitialGuess(config["T"]) # Separator electrolyte initialization if config["have_separator"]: