Notifications
You must be signed in to change notification settings - Fork 11
/
wizcmdset.py
284 lines (261 loc) · 12.6 KB
/
wizcmdset.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
import re
from utils import logger
from WIZMakeCMD import ONE_PORT_DEV, TWO_PORT_DEV, SECURITY_DEVICE
ip_pattern = "^(([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|25[0-5])\.){3}([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|25[0-5])$"
port_pattern = "^([0-9]|[1-9][0-9]{1,3}|[1-5][0-9]{4}|6[0-4][0-9][0-9][0-9]|65[0-4][0-9][0-9]|655[0-2][0-9]|6553[0-5])$"
baudrate_option = {"0": "300", "1": "600", "2": "1200", "3": "1800", "4": "2400", "5": "4800", "6": "9600", "7": "14400", "8": "19200", "9": "28800", "10": "38400", "11": "57600", "12": "115200", "13": "230400"}
opmode_option = {"0": "TCP Client mode", "1": "TCP Server mode", "2": "TCP Mixed mode", "3": "UDP mode"}
common_cmdset = {
"MC": ["MAC address", "^([0-9a-fA-F]{2}:){5}([0-9a-fA-F]{2})$", {}, "RO"],
"VR": ["Firmware Version", "", {}, "RO"],
"MN": ["Product Name", "", {}, "RO"],
"ST": ["Operation status", "", {}, "RO"],
"UN": ["UART Interface(Str)", "", {}, "RO"],
"UI": ["UART Interface(Code)", "", {}, "RO"],
# WIZ750SR: F/W 1.2.0 verison or later
"TR": ["TCP Retransmission Retry count", "^([1-9]|[1-9][0-9]|1[0-9][0-9]|2[0-5][0-5])$", {}, "RW"],
"OP": ["Network Operation Mode", "^[0-3]$", opmode_option, "RW"],
"IM": ["IP address Allocation Mode", "^[0-1]$", {"0": "Static IP", "1": "DHCP"}, "RW"],
"LI": ["Local IP address", ip_pattern, {}, "RW"],
"SM": ["Subnet mask", ip_pattern, {}, "RW"],
"GW": ["Gateway address", ip_pattern, {}, "RW"],
"DS": ["DNS Server address", ip_pattern, {}, "RW"],
"LP": ["Local port number", port_pattern, {}, "RW"],
"RH": ["Remote Host IP address", ip_pattern, {}, "RW"],
"RP": ["Remote Host Port number", port_pattern, {}, "RW"],
"BR": ["UART Baud rate", "^([0-9]|1[0-4])$", baudrate_option, "RW"],
"DB": ["UART Data bit length", "^[0-1]$", {"0": "7-bit", "1": "8-bit"}, "RW"],
"PR": ["UART Parity bit", "^[0-2]$", {"0": "NONE", "1": "ODD", "2": "EVEN"}, "RW"],
"SB": ["UART Stop bit length", "^[0-1]$", {"0": "1-bit", "1": "2-bit"}, "RW"],
"FL": [
"UART Flow Control",
"^[0-4]$",
{"0": "NONE", "1": "XON/XOFF", "2": "RTS/CTS", "3": "RTS on TX", "4": "RTS on TX (invert)"},
"RW"
],
"PT": ["Time Delimiter", port_pattern, {}, "RW"],
"PS": ["Size Delimiter", "^([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|25[0-5])$", {}, "RW"],
# "PD" : ["Char Delimiter", "^([0-7][0-9a-fA-F])$", {}, "RW"],
"PD": ["Char Delimiter", "^([0-9a-fA-F][0-9a-fA-F])$", {}, "RW"],
"IT": ["Inactivity Timer Value", port_pattern, {}, "RW"],
"CP": ["Connection Password Enable", "^[0-1]$", {}, "RW"],
"NP": ["Connection Password", "", {}, "RW"],
"SP": ["Search ID Code", "", {}, "RW"],
# "DG" : ["Serial Debug Message Enable", "^[0-1]$", {}, "RW"],
# debug msg test
"DG": ["Serial Debug Message Enable", "^[0-4]$", {}, "RW"],
"KA": ["TCP Keep-alive Enable", "^[0-1]$", {}, "RW"],
"KI": ["TCP Keep-alive Initial Interval", port_pattern, {}, "RW"],
"KE": ["TCP Keep-alive Retry Interval", port_pattern, {}, "RW"],
"RI": ["TCP Reconnection Interval", port_pattern, {}, "RW"],
"EC": ["Serial Command Echoback Enable", "^[0-1]$", {}, "RW"],
"TE": ["Command mode Switch Code Enable", "^[0-1]$", {}, "RW"],
"SS": ["Command mode Switch Code", "^(([0-9a-fA-F][0-9a-fA-F]){3})$", {}, "RW"],
"CA": [
"Type and Direction of User I/O pin A",
"^[0-2]$",
{"0": "Digital Input", "1": "Digital Output", "2": "Analog Input"},
"RW",
],
"CB": [
"Type and Direction of User I/O pin B",
"^[0-2]$",
{"0": "Digital Input", "1": "Digital Output", "2": "Analog Input"},
"RW",
],
"CC": [
"Type and Direction of User I/O pin C",
"^[0-2]$",
{"0": "Digital Input", "1": "Digital Output", "2": "Analog Input"},
"RW",
],
"CD": [
"Type and Direction of User I/O pin D",
"^[0-2]$",
{"0": "Digital Input", "1": "Digital Output", "2": "Analog Input"},
"RW",
],
"GA": ["Status and Value of User I/O pin A", "^[0-1]$", {"0": "Low", "1": "High"}, "RW"],
"GB": ["Status and Value of User I/O pin B", "^[0-1]$", {"0": "Low", "1": "High"}, "RW"],
"GC": ["Status and Value of User I/O pin C", "^[0-1]$", {"0": "Low", "1": "High"}, "RW"],
"GD": ["Status and Value of User I/O pin D", "^[0-1]$", {"0": "Low", "1": "High"}, "RW"],
"SC": [
"Status pin S0 and S1 Operation Mode Setting",
"^([0-1]{2})$",
{"00": "PHY Link Status or TCP Connection Status", "11": "DTR/DSR"},
"RW"
],
"S0": [
"Status of pin S0 (PHY Link or DTR)",
"^[0-1]$",
{
"0": "PHY Link Up or The device is not ready",
"1": "PHY Link Down or The device ready for communication",
},
"RO"
],
"S1": [
"Status of pin S1 (TCP Connection or DST)",
"^[0-1]$",
{
"0": "PHY Link Up or The device is not ready",
"1": "PHY Link Down or The device ready for communication",
},
"RO"
],
"EX": ["Command mode exit", "", {}, "WO"],
"SV": ["Save Device Setting", "", {}, "WO"],
"RT": ["Device Reboot", "", {}, "WO"],
"FR": ["Device Factory Reset", "", {}, "WO"]
}
WIZ75X_CMDSET = {
**common_cmdset,
"TR": ["TCP Retransmission Retry count", "^([1-9]|[1-9][0-9]|1[0-9][0-9]|2[0-5][0-5])$", {}, "RW"],
}
WIZ510SSL_CMDSET = {
**common_cmdset,
# "SU": ["MQTT options - Subscribe topic", "", {}, "RW"],
"BA": ["Current Flash Bank", "", {}, "RO"],
}
WIZ5XX_RP_CMDSET = {
**common_cmdset,
"OP": [
"Network Operation Mode - Extended",
"^[0-6]$",
{**opmode_option, "4": "SSL TCP Client mode", "5": "MQTT Client", "6": "MQTTS Client"},
"RW",
],
"SO": ["SSL receive timeout", "", {}, "RW"],
"QU": ["MQTT Options - User name", "", {}, "RW"],
"QP": ["MQTT options - Password", "", {}, "RW"],
"QC": ["MQTT options - Client ID", "", {}, "RW"],
"QK": ["MQTT Keep-Alive", "", {}, "RW"],
"PU": ["MQTT Publish topic", "", {}, "RW"],
"U0": ["MQTT Subscribe topic 1", "", {}, "RW"],
"U1": ["MQTT Subscribe topic 2", "", {}, "RW"],
"U2": ["MQTT Subscribe topic 3", "", {}, "RW"],
"QO": ["MQTT QoS level", "^[0-2]$", {}, "RW"],
"RC": ["Root CA Option", "^[0-2]$", {}, "RW"],
"CE": ["Client Certificate Enable", "^[0-1]$", {}, "RW"],
"OC": ["Root CA", "", {}, "WO"],
"LC": ["Client Certificate", "", {}, "WO"],
"PK": ["Private Key", "", {}, "WO"],
"UF": ["Copy firmware from firmware binary bank to application bank", "", {}, "RW"],
"PO": ["Status of Modbus protocol", "^[0-2]$", {}, "RO"],
}
# Two port devices
WIZ752_CMDSET = {
**common_cmdset,
"ST": ["Operation status for channel 0", "", {}, "RO"],
"QS": ["Operation status for channel 1", "", {}, "RO"],
"UN": ["UART Interface(Str) for channel 0", "", {}, "RO"],
"EN": ["UART Interface(Str) for channel 1", "", {}, "RO"],
"UI": ["UART Interface(Code) for channel 0", "", {}, "RO"],
"TR": ["TCP Retransmission Retry count", "^([1-9]|[1-9][0-9]|1[0-9][0-9]|2[0-5][0-5])$", {}, "RW"],
"EI": ["UART Interface(Code) for channel 1", "", {}, "RO"],
"OP": ["Network Operation Mode for channel 0", "^[0-3]$", opmode_option, "RW"],
"QO": ["Network Operation Mode for channel 1", "^[0-3]$", opmode_option, "RW"],
"LP": ["Local port number for channel 0", port_pattern, {}, "RW"],
"QL": ["Local port number for channel 1", port_pattern, {}, "RW"],
"RH": ["Remote Host IP address for channel 0", ip_pattern, {}, "RW"],
"QH": ["Remote Host IP address for channel 1", ip_pattern, {}, "RW"],
"RP": ["Remote Host Port number for channel 0", port_pattern, {}, "RW"],
"QP": ["Remote Host Port number for channel 1", port_pattern, {}, "RW"],
"BR": ["UART channel 0 Baud rate", "^([0-9]|1[0-3])$", baudrate_option, "RW"],
"EB": ["UART channel 1 Baud rate", "^([0-9]|1[0-3])$", baudrate_option, "RW"],
"DB": ["UART channel 0 Data bit length", "^[0-1]$", {"0": "7-bit", "1": "8-bit"}, "RW"],
"ED": ["UART channel 1 Data bit length", "^[0-1]$", {"0": "7-bit", "1": "8-bit"}, "RW"],
"PR": ["UART channel 0 Parity bit", "^[0-2]$", {"0": "NONE", "1": "ODD", "2": "EVEN"}, "RW"],
"EP": ["UART channel 1 Parity bit", "^[0-2]$", {"0": "NONE", "1": "ODD", "2": "EVEN"}, "RW"],
"SB": ["UART channel 0 Stop bit length", "^[0-1]$", {"0": "1-bit", "1": "2-bit"}, "RW"],
"ES": ["UART channel 1 Stop bit length", "^[0-1]$", {"0": "1-bit", "1": "2-bit"}, "RW"],
"FL": ["UART channel 0 Flow Control", "^[0-2]$", {"0": "NONE", "1": "XON/XOFF", "2": "RTS/CTS"}, "RW"],
"EF": ["UART channel 1 Flow Control", "^[0-2]$", {"0": "NONE", "1": "XON/XOFF", "2": "RTS/CTS"}, "RW"],
"PT": ["Time Delimiter for channel 0", port_pattern, {}, "RW"],
"NT": ["Time Delimiter for channel 1", port_pattern, {}, "RW"],
"PS": ["Size Delimiter for channel 0", "^([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|25[0-5])$", {}, "RW"],
"NS": ["Size Delimiter for channel 1", "^([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|25[0-5])$", {}, "RW"],
"PD": ["Char Delimiter for channel 0", "^([0-9a-fA-F][0-9a-fA-F])$", {}, "RW"],
"ND": ["Char Delimiter for channel 1", "^([0-9a-fA-F][0-9a-fA-F])$", {}, "RW"],
"IT": ["Inactivity Timer Value for channel 0", port_pattern, {}, "RW"],
"RV": ["Inactivity Timer Value for channel 1", port_pattern, {}, "RW"],
"CP": ["Connection Password Enable", "^[0-1]$", {}, "RW"],
"NP": ["Connection Password", "", {}, "RW"],
"SP": ["Search ID Code", "", {}, "RW"],
"DG": ["Serial Debug Message Enable", "^[0-4]$", {}, "RW"],
"KA": ["TCP Keep-alive Enable for channel 0", "^[0-1]$", {}, "RW"],
"RA": ["TCP Keep-alive Enable for channel 1", "^[0-1]$", {}, "RW"],
"KI": ["TCP Keep-alive Initial Interval for channel 0", port_pattern, {}, "RW"],
"RS": ["TCP Keep-alive Initial Interval for channel 1", port_pattern, {}, "RW"],
"KE": ["TCP Keep-alive Retry Interval for channel 0", port_pattern, {}, "RW"],
"RE": ["TCP Keep-alive Retry Interval for channel 1", port_pattern, {}, "RW"],
"RI": ["TCP Reconnection Interval for channel 0", port_pattern, {}, "RW"],
"RR": ["TCP Reconnection Interval for channel 1", port_pattern, {}, "RW"],
}
class Wizcmdset():
def __init__(self, name):
self.name = name
self.cmdset = common_cmdset
self.get_cmdset(self.name)
def get_cmdset(self, name):
if name in ONE_PORT_DEV:
logger.debug('One port device')
self.cmdset = WIZ75X_CMDSET
elif name in SECURITY_DEVICE:
logger.debug('Security device')
self.cmdset = WIZ5XX_RP_CMDSET
elif name in TWO_PORT_DEV:
logger.debug('Two port device')
self.cmdset = WIZ752_CMDSET
else:
logger.debug('Default device')
self.cmdset = WIZ75X_CMDSET
def isvalidcommand(self, cmdstr):
if cmdstr in self.cmdset.keys():
return True
return False
def isvalidparameter(self, cmdstr, param):
logger.debug(f'command: {cmdstr}, param: {param}')
if self.isvalidcommand(cmdstr):
prog = re.compile(self.cmdset[cmdstr][1])
# for domain name
if cmdstr == "RH":
# ! Need check size
return True
if prog.match(param):
# logger.debug("Valid %s" % self.cmdset[cmdstr][0])
return True
else:
logger.debug("Invalid %s" % self.cmdset[cmdstr][0])
return False
else:
logger.debug(f"## Invalid command: {cmdstr}")
logger.debug(f"## Invalid parameter: {cmdstr}, {param}")
return False
def getparamdescription(self, cmdstr, param):
if self.isvalidparameter(cmdstr, param):
if len(self.cmdset[cmdstr][2]) > 0:
return self.cmdset[cmdstr][2][param]
else:
return param
def getcmddescription(self, cmdstr):
if self.isvalidcommand(cmdstr):
return self.cmdset[cmdstr][0]
else:
return "Invalid command"
def iswritable(self, cmdstr):
if self.cmdset[cmdstr][3] == "RW":
return True
return False
if __name__ == "__main__":
# wizcmdset = Wizcmdset("WIZ750SR")
wizcmdset = Wizcmdset("WIZ752SR-12x")
cmdlist = wizcmdset.cmdset.items()
# 각 command에 대한 정보 출력 => log 기록 시 활용
# cmd = "SS"
cmd = "QH"
print('"%s": %s\n %s\n' % (cmd, wizcmdset.cmdset[cmd][0], wizcmdset.cmdset[cmd][2]))
# 함수 활용
print(wizcmdset.getcmddescription(cmd))
print(wizcmdset.getparamdescription(cmd, "2B2C2D"))
print(wizcmdset.isvalidparameter(cmd, "192.168.11.3"))