-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathpsf2Edward.log
54 lines (44 loc) · 2.31 KB
/
psf2Edward.log
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
Checking platform configuration ...
IPNAME:plb_v46 INSTANCE:plb -
/home/aalonso/workspace/ppc405/xilinx-ml405-ref/system.mhs line 82 - 2 master(s)
: 13 slave(s)
IPNAME:plb_v46 INSTANCE:ppc405_0_iplb1 -
/home/aalonso/workspace/ppc405/xilinx-ml405-ref/system.mhs line 224 - 1
master(s) : 1 slave(s)
IPNAME:plb_v46 INSTANCE:ppc405_0_dplb1 -
/home/aalonso/workspace/ppc405/xilinx-ml405-ref/system.mhs line 231 - 1
master(s) : 1 slave(s)
Checking port drivers...
WARNING:EDK:2098 - PORT:HostMiimRdy CONNECTOR:host_mii_rdy -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 262 - No driver found. Port will be
driven to GND!
WARNING:EDK:2098 - PORT:HostRdData CONNECTOR:host_rd_data -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 263 - No driver found. Port will be
driven to GND!
WARNING:EDK:2099 - PORT:HostMiimSel CONNECTOR:host_mii_sel -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 264 - floating connection!
WARNING:EDK:2099 - PORT:HostReq CONNECTOR:host_req -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 265 - floating connection!
WARNING:EDK:2099 - PORT:HostAddr CONNECTOR:host_addr -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 266 - floating connection!
WARNING:EDK:2099 - PORT:HostEmac1Sel CONNECTOR:host_emac1_sel -
/opt/Xilinx/12.1/ISE_DS/EDK/hw/XilinxProcessorIPLib/pcores/xps_ll_temac_v2_03
_a/data/xps_ll_temac_v2_1_0.mpd line 267 - floating connection!
Performing Clock DRCs...
Performing Reset DRCs...
Overriding system level properties...
WARNING:EDK:1557 - IPNAME:ppc405_virtex4 INSTANCE:ppc405_0 -
/home/aalonso/workspace/ppc405/xilinx-ml405-ref/system.mhs line 68 -
PARAMETER C_FASTEST_PLB_CLOCK has value DPLB1 specified in MHS, but tcl is
overriding the value to DPLB0
Running system level update procedures...
Running UPDATE Tcl procedures for OPTION SYSLEVEL_UPDATE_PROC...
Running system level DRCs...
Performing System level DRCs on properties...
Running DRC Tcl procedures for OPTION SYSLEVEL_DRC_PROC...
Conversion to XML complete.