function calcErr, volRates, tensions, alpha, logKs, R_disc
Ks=10.0^logKs
Q= Ks*2.71828^(alpha*(-1)*tensions) * (1.0+(4.0/(!pi*R_disc*alpha)))
return, sqrt(mean((volRates-Q)^2.0))
end
pro inf_rate, dataFname, infoFname, col=col
if not keyword_set(col) then col=5
j=load_cols(dataFname, data)
j=load_cols(infoFname, info)
R_resevoir=2.25 ; resevoir tube radius
R_disc=20.0 ; infiltration disc radius
infVolume=fltarr(n_elements(info[0,*]))
infRates=fltarr(n_elements(info[0,*]))
tension=fltarr(n_elements(info[0,*]))
;; info file contains column formated data,
;; one line for each tension measured
;; column 0 = column in data file
;; column 1 = site number
;; column 2 = tension index (0-n) used so we can combine multiple intervals
;; column 3 = start position for current interval
;; column 4 = stop position for current interval
;; column 5 = top of water in bubbling tube
;; column 6 = bottom of air entry tube
time =fix(data[3,*]/100)+fix(data[3,*] mod 100)/60.0 + data[4,*]/3600.0
tmp=''
!p.multi=[0,1,2]
for i=0, n_elements(info[0,*])-1 do begin
col=info[0,i]
; startX=(where(data[3,*] eq info[0,i]))[0]
; endX=(where(data[3,*] eq info[1,i]))[0]
startX=info[3,i]
endX=info[4,i]
tension[i]=info[6,i]-info[5,i];;-3.2 ; minus the offset for the given infiltrometer
line=linfit(time[startX:endX], data[col, startX:endX], sigma=deviation)
r=correlate(time[startX:endX], data[col, startX:endX])
infVolume[i] = abs(line[0]*!pi * R_resevoir^2.0)
infRates[i] = infVolume[i]/(!pi*R_disc^2.0)
print, tension[i], info[1,i], line[1], deviation[1], r^2, infRates[i], format='(7F10.3)'
plot, time[startX:endX], data[col,startX:endX], psym=2, /xs, /ys
oplot, time[startX:endX], time[startX:endX]*line[1]+line[0], l=2
plot, data[col,startX:endX] - (time[startX:endX]*line[1]+line[0]), psym=2
; read, tmp
endfor
minErr=100000.0
trueA=-9999.9
trueK=-9999.9
;; loop through reasonable values of Ks and alpha (I don't really
;; know the range of values to search so I may need to expand
;; this).
nsites=max(info[1,*])
window, 1, xs=1000, ys=1000
!p.multi=[0,2,2]
FOR curSite=1,nsites DO begin
sitedex=where(info[1,*] EQ curSite)
plot, tension[sitedex], infVolume[sitedex], psym=2, xr=[0,25]
wait, 0.1
for alpha=0.0001,0.4, 0.0001 do begin
for logKs=3.0,3.5, 0.0001 do begin
err=calcErr(infVolume[sitedex], tension[sitedex], alpha, logKs, R_disc)
if err lt minErr then begin
minErr=err
trueA=alpha
trueK=logKs
endif
ENDFOR
; IF alpha MOD 10 LT 0.1 THEN print, round(alpha)
ENDFOR
tmptensions=indgen(26)
oplot, indgen(26), (10.0^trueK)*2.71828^(trueA*(-1)*tmptensions) * (1.0+(4.0/(!pi*R_disc*trueA)))
print, curSite, trueA, trueK
ENDFOR
wset, 0
end