switch display information misleading #5

Open
shockwang opened this issue Mar 17, 2015 · 0 comments
Open

switch display information misleading #5

shockwang opened this issue Mar 17, 2015 · 0 comments

Comments

@shockwang
Copy link

Cbench prints result when finishing a test round, in the format like
"switches: flows/sec xxx xxx xxx xxx total = xxx"

The "flows/sec" make me believe the number print means "how many flows installed to a single switch per second". However, after I did few tests and also traced the code, I believe the number print means "total flows installed in this test period".

If my understanding correct, I suggest "total flow per switch" instead of "flows/sec" to prevent misunderstanding. Thanks.