The Telink Lighting Example demonstrates how to remotely control a white dimmable light bulb. It uses buttons to test changing the lighting and device states and LEDs to show the state of these changes. You can use this example as a reference for creating your own application.
-
Run the Docker container:
$ docker run -it --rm -v $PWD:/host -w /host ghcr.io/project-chip/chip-build-telink:$(wget -q -O - https://raw.githubusercontent.com/project-chip/connectedhomeip/master/.github/workflows/examples-telink.yaml 2> /dev/null | grep chip-build-telink | awk -F: '{print $NF}')
Compatible docker image version can be found in next file:
$ .github/workflows/examples-telink.yaml
-
Activate the build environment:
$ source ./scripts/activate.sh
-
In the example dir run (replace <build_target> with your board name, for example,
tlsr9518adk80d
ortlsr9528a
):$ west build -b <build_target>
-
Flash binary:
$ west flash --erase
To get output from device, connect UART to following pins:
Name | Pin |
---|---|
RX | PB3 (pin 17 of J34 connector) |
TX | PB2 (pin 16 of J34 connector) |
GND | GND |
The following buttons are available on tlsr9518adk80d board:
Name | Function | Description |
---|---|---|
Button 1 | Factory reset | Perform factory reset to forget currently commissioned Thread network and back to uncommissioned state |
Button 2 | Lighting control | Manually triggers the lighting state |
Button 3 | Thread start | Commission thread with static credentials and enables the Thread on device |
Button 4 | Open commission window | The button is opening commissioning window to perform commissioning over BLE |
Red LED indicates current state of Thread network. It is able to be in following states:
State | Description |
---|---|
Blinks with short pulses | Device is not commissioned to Thread, Thread is disabled |
Blinks with frequent pulses | Device is commissioned, Thread enabled. Device trying to JOIN thread network |
Blinks with wide pulses | Device commissioned and joined to thread network as CHILD |
Green LED used to identify the device. The LED starts blinking when the Identify command of the Identify cluster is received. The command's argument can be used to specify the the effect. It is able to be in following effects:
Effect | Description |
---|---|
Blinks (200 ms on/200 ms off) | Blink (Clusters::Identify::EffectIdentifierEnum::kBlink ) |
Breathe (during 1000 ms) | Breathe (Clusters::Identify::EffectIdentifierEnum::kBreathe ) |
Blinks (50 ms on/950 ms off) | Okay (Clusters::Identify::EffectIdentifierEnum::kOkay ) |
Blinks (1000 ms on/1000 ms off) | Channel Change ( Clusters::Identify::EffectIdentifierEnum::kChannelChange ) |
Blinks (950 ms on/50 ms off) | Finish ( Clusters::Identify::EffectIdentifierEnum::kFinishEffect ) |
LED off | Stop (Clusters::Identify::EffectIdentifierEnum::kStopEffect ) |
By default, only Blue LED is used to show current state of lightbulb (only for lightning-app).
To enable RGB functionality in Your application set this config:
In Matter examples/lighting-app/telink/include/AppConfig.h, set the define
USE_RGB_PWM
:
define USE_RGB_PWM 1
To get current state of lightbulb in RGB mode, connect 3-color LED module to following pins:
Name | Pin |
---|---|
Red | PE2 (pin 8 of J34) |
Green | PE0 (pin 5 of J34) |
Blue | PB4 (pin 20 of J34) |
GND | GND (pin 24 of J50) |
-
Build chip-tool cli
-
Pair with device
${CHIP_TOOL_DIR}/chip-tool pairing ble-thread ${NODE_ID} hex:${DATASET} ${PIN_CODE} ${DISCRIMINATOR}
Example:
./chip-tool pairing ble-thread 1234 hex:0e080000000000010000000300000f35060004001fffe0020811111111222222220708fd61f77bd3df233e051000112233445566778899aabbccddeeff030e4f70656e54687265616444656d6f010212340410445f2b5ca6f2a93a55ce570a70efeecb0c0402a0fff8 20202021 3840
-
Switch on the light:
${CHIP_TOOL_DIR}/chip-tool onoff on 1
here:
- onoff is name of cluster
- on command to the cluster
- 1 ID of endpoint
-
Switch off the light:
${CHIP_TOOL_DIR}/chip-tool onoff off 1
here:
- onoff is name of cluster
- off command to the cluster
- 1 ID of endpoint
-
Read the light state:
${CHIP_TOOL_DIR}/chip-tool onoff read on-off 1
here:
- onoff is name of cluster
- read command to the cluster
- on-off attribute to read
- 1 ID of endpoint
-
Change brightness of light:
${CHIP_TOOL_DIR}/chip-tool levelcontrol move-to-level 32 0 0 0 1
here:
- levelcontrol is name of cluster
- move-to-level command to the cluster
- 32 brightness value
- 0 transition time
- 0 option mask
- 0 option override
- 1 ID of endpoint
-
Read brightness level:
./chip-tool levelcontrol read current-level 1
here:
- levelcontrol is name of cluster
- read command to the cluster
- current-level attribute to read
- 1 ID of endpoint
OTA feature enabled by default only for ota-requestor-app example. To enable OTA feature for another Telink example:
- set CONFIG_CHIP_OTA_REQUESTOR=y in corresponding "prj.conf" configuration file.
After build application with enabled OTA feature, use next binary files:
- zephyr.bin - main binary to flash PCB (Use 2MB PCB).
- zephyr-ota.bin - binary for OTA Provider
All binaries has the same SW version. To test OTA “zephyr-ota.bin” should have higher SW version than base SW. Set CONFIG_CHIP_DEVICE_SOFTWARE_VERSION=2 in corresponding “prj.conf” configuration file.
Usage of OTA:
-
Build the Linux OTA Provider
./scripts/examples/gn_build_example.sh examples/ota-provider-app/linux out/ota-provider-app chip_config_network_layer_ble=false
-
Run the Linux OTA Provider with OTA image.
./chip-ota-provider-app -f zephyr-ota.bin
-
Provision the Linux OTA Provider using chip-tool
./chip-tool pairing onnetwork ${OTA_PROVIDER_NODE_ID} 20202021
here:
- ${OTA_PROVIDER_NODE_ID} is the node id of Linux OTA Provider
-
Configure the ACL of the ota-provider-app to allow access
./chip-tool accesscontrol write acl '[{"fabricIndex": 1, "privilege": 5, "authMode": 2, "subjects": [112233], "targets": null}, {"fabricIndex": 1, "privilege": 3, "authMode": 2, "subjects": null, "targets": null}]' ${OTA_PROVIDER_NODE_ID} 0
here:
- ${OTA_PROVIDER_NODE_ID} is the node id of Linux OTA Provider
-
Use the chip-tool to announce the ota-provider-app to start the OTA process
./chip-tool otasoftwareupdaterequestor announce-otaprovider ${OTA_PROVIDER_NODE_ID} 0 0 0 ${DEVICE_NODE_ID} 0
here:
- ${OTA_PROVIDER_NODE_ID} is the node id of Linux OTA Provider
- ${DEVICE_NODE_ID} is the node id of paired device
Once the transfer is complete, OTA requestor sends ApplyUpdateRequest command to OTA provider for applying the image. Device will restart on successful application of OTA image.
The RPCs in lighting-common/lighting_service/lighting_service.proto
can be
used to control various functionalities of the lighting app from a USB-connected
host computer. To build the example with the RPC server, run the following
command with build-target replaced with the build target name of the Telink
Semiconductor's kit you own:
```
$ west build -b tlsr9518adk80d -- -DOVERLAY_CONFIG=rpc.overlay
```