diff --git a/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md b/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md index 679795f2e8..f432d39bc8 100644 --- a/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md +++ b/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md @@ -191,11 +191,11 @@ JSON file. See [Common metadata fields](#common-metadata-fields) for a list of terms and their definitions. There are also some OPTIONAL JSON fields specific to anatomical scans: -| **Key name** | **Requirement level** | **Data type** | **Description** | -| ----------------------- | --------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------------- | -| ContrastBolusIngredient | OPTIONAL | [string][] | Active ingredient of agent. Values MUST be one of: IODINE, GADOLINIUM, CARBON DIOXIDE, BARIUM, XENON Corresponds to DICOM Tag 0018,1048. | -| RepetitionTimeExcitation | OPTIONAL | [number][] | The time in seconds between successive excitation pulses that excite a spin system. The DICOM tag that best refers to this parameter is [(0018, 0080)](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0018,0080)). This field may be used together with the `RepetitionTimePreparation` for certain use cases, such as [MP2RAGE](https://infoscience.epfl.ch/record/172927/files/mp2rage.pdf). Use `RepetitionTimeExcitation` (in combination with `RepetitionTimePreparation` if needed) for anatomy imaging data rather than `RepetitionTime` as it is already defined as the amount of time that it takes to acquire a single volume in the [task imaging data](#task-including-resting-state-imaging-data) section.| -| RepetitionTimePreparation | OPTIONAL | [number][] | The period of time in seconds that it takes a preparation pulse block to re-appear at the beginning of the succeeding (essentially identical) pulse sequence block. | +| **Key name** | **Requirement level** | **Data type** | **Description** | +| ----------------------- | --------------------- | -------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | +| ContrastBolusIngredient | OPTIONAL | [string][] | Active ingredient of agent. Values MUST be one of: IODINE, GADOLINIUM, CARBON DIOXIDE, BARIUM, XENON Corresponds to DICOM Tag 0018,1048. | +| RepetitionTimeExcitation | OPTIONAL | [number][] | The time elapses (in seconds) between two successive excitations. The DICOM tag that best refers to this parameter is [(0018, 0080)](http://dicomlookup.com/lookup.asp?sw=Tnumber&q=(0018,0080)). This field may be used together with the `RepetitionTimePreparation` for certain use cases, such as [MP2RAGE](https://infoscience.epfl.ch/record/172927/files/mp2rage.pdf). Use `RepetitionTimeExcitation` (in combination with `RepetitionTimePreparation` if needed) for anatomy imaging data rather than `RepetitionTime` as it is already defined as the amount of time that it takes to acquire a single volume in the [task imaging data](#task-including-resting-state-imaging-data) section. | +| RepetitionTimePreparation | OPTIONAL | [number][] or [array][] of [numbers][] | The period of time in seconds that it takes a preparation pulse block to re-appear at the beginning of the succeeding (essentially identical) pulse sequence block. The data type number may apply to files from any MRI modality concerned with a single value for this field. The data type array provides a value for each volume in a 4D dataset and should only be used when the volume timing is critical for interpretation of the data, such as in [ASL](#arterial-spin-labeling-perfusion-data). | Similarly, the OPTIONAL [`rec-