function mpc = case6ww
%CASE6WW Power flow data for 6 bus, 3 gen case from Wood & Wollenberg.
% Please see CASEFORMAT for details on the case file format.
%
% This is the 6 bus example from pp. 104, 112, 119, 123-124, 549 of
% "Power Generation, Operation, and Control, 2nd Edition",
% by Allen. J. Wood and Bruce F. Wollenberg, John Wiley & Sons, NY, Jan 1996.
% MATPOWER
% $Id: case6ww.m,v 1.7 2010/03/10 18:08:15 ray Exp $
%% MATPOWER Case Format : Version 2
mpc.version = '2';
%%----- Power Flow Data -----%%
%% system MVA base
mpc.baseMVA = 100;
%% bus data
% bus_i type Pd Qd Gs Bs area Vm Va baseKV zone Vmax Vmin
mpc.bus = [
1 3 0 0 0 0 1 1.05 0 230 1 1.05 1.05;
2 2 0 0 0 0 1 1.05 0 230 1 1.05 1.05;
3 2 0 0 0 0 1 1.07 0 230 1 1.07 1.07;
4 1 70 70 0 0 1 1 0 230 1 1.05 0.95;
5 1 70 70 0 0 1 1 0 230 1 1.05 0.95;
6 1 70 70 0 0 1 1 0 230 1 1.05 0.95;
];
%% generator data
% bus Pg Qg Qmax Qmin Vg mBase status Pmax Pmin Pc1 Pc2 Qc1min Qc1max Qc2min Qc2max ramp_agc ramp_10 ramp_30 ramp_q apf
mpc.gen = [
1 0 0 100 -100 1.05 100 1 200 50 0 0 0 0 0 0 0 0 0 0 0;
2 50 0 100 -100 1.05 100 1 150 37.5 0 0 0 0 0 0 0 0 0 0 0;
3 60 0 100 -100 1.07 100 1 180 45 0 0 0 0 0 0 0 0 0 0 0;
];
%% branch data
% fbus tbus r x b rateA rateB rateC ratio angle status angmin angmax
mpc.branch = [
1 2 0.1 0.2 0.04 40 40 40 0 0 1 -360 360;
1 4 0.05 0.2 0.04 60 60 60 0 0 1 -360 360;
1 5 0.08 0.3 0.06 40 40 40 0 0 1 -360 360;
2 3 0.05 0.25 0.06 40 40 40 0 0 1 -360 360;
2 4 0.05 0.1 0.02 60 60 60 0 0 1 -360 360;
2 5 0.1 0.3 0.04 30 30 30 0 0 1 -360 360;
2 6 0.07 0.2 0.05 90 90 90 0 0 1 -360 360;
3 5 0.12 0.26 0.05 70 70 70 0 0 1 -360 360;
3 6 0.02 0.1 0.02 80 80 80 0 0 1 -360 360;
4 5 0.2 0.4 0.08 20 20 20 0 0 1 -360 360;
5 6 0.1 0.3 0.06 40 40 40 0 0 1 -360 360;
];
%%----- OPF Data -----%%
%% generator cost data
% 1 startup shutdown n x1 y1 ... xn yn
% 2 startup shutdown n c(n-1) ... c0
mpc.gencost = [
2 0 0 3 0.00533 11.669 213.1;
2 0 0 3 0.00889 10.333 200;
2 0 0 3 0.00741 10.833 240;
];