Hi @alexsayal, I'm troubleshooting the error you found. Thanks for sending a sample dataset, but I'm finding the dataset shorter than expected based on the timing in the files. Did you delete a bunch of values to make the files smaller? That would explain the discrepancy... Thanks, -Pablo |
Hi @pvelasco, Sorry for that, the files I sent are cut at around 5 minutes due to the lack of a ECG signal (a limitation of the ideacmdtool on the new XA30 version that we only now acknowledged). I re-send some complete files. Thank you, |
Hi @pvelasco , Any news regarding this update? Thank you in advance for this |
One important difference between these files and the ones by VE11 is that multiple regions of 5002 ... 6002 exist, as explained here - https://gitlab.ethz.ch/physio/physio-doc/-/wikis/MANUAL_PART_READIN#updates-logversion-3 |
I have now made a suggestion in #9 |
Hello all,
Our MRI console software was recently updated to XA30. This led us to use ideacmdtool to record physiological signals, which are generated in .pmu, .puls, .ecg, and .resp formats.
I tried using the pmu2bidsphysio function to process them, but I get the following error:
I deduce that the files have somehow changed in this version and hence are not compatible. I attach these files.
PL01R1AP.zip
I thank you in advance for any help you can provide regarding this problem.
All the best,