CAT5e cabling between the UDM to the managed switches and Unifi access points creates the physical backbone of the network:
The cabling between UDM, switches and the APs are all part of the untagged, native LAN. Since that portion of the network carries multiple VLANs, it's also referred to as trunked connections.
All managed Unifi switches and Unifi Access Points acquire their IP address via DHCP.
Profile Name | Native Network | Tagged Networks |
---|---|---|
OFF | none | none |
mgmt-90 | mgmt-90 | none |
mgmt | mgmt-90 | mgmt (90) |
Wired-VLANs | mgmt-90 | home (10), guest (20), IoT (30), media (40), camera (50) |
Wireless-AP-VLANs | mgmt-90 | home (10), guest (20), IoT (30), media (40) |
Port | Link name | Profile Name |
---|---|---|
1 | to US-8-150W-garage | Wired-VLANs |
3 | to US-8-60W-office | Wired-VLANs |
8 | direct mgmt access (laptop) | mgmt |
9 | uplink to T-Mobile ISP | All |
All unused ports are configured with profile OFF
Port | Link name | Profile Name | PoE |
---|---|---|---|
1 | AP-LivingRoom | Wireless-AP-VLANs | PoE/PoE+ |
2 | AP-Studio | Wireless-AP-VLANs | PoE/PoE+ |
3 | AP-garage | Wireless-AP-VLANs | 24V Passive |
9 | Uplink to UDM | Wired-VLANs | (SFP 1GbE) |
10 | downlink to Netgear GS108 | All | (SFP 1GbE) |
All unused ports are configured with profile OFF
Port | Link name | Profile Name | PoE |
---|---|---|---|
1 | uplink to UDM | Wired-VLANs | none |
2 | mgmt-office | mgmt-90 | none |
3 | home-office | home (10) | none |
All unused ports are configured with profile OFF
All APs connect via trunk (mgmt-90) as management LAN
SSID | Network | WiFi bands | Sec Protocol | Extras |
---|---|---|---|---|
jenni.ap | home (10) | Both | WPA-2/WPA-3 | Hi Perf Devices |
jenni.guest | guest (20) | Both | WPA-2/WPA-3 | L2 Isolation |
jenni.IoT | IoT (30) | 2.4 GHz | WPA-2 | Multicast Enhancement |
jenni.media | media (40) | Both | WPA-2/WPA-3 | Multicast Enhancement |