All scripts uses my library libuvk5.py
. Scripts tested only on windows.
To read write access COM Port (Serial/USB Cable) must be the Serial Module installed into Python.
Install from command prompt/cmd the serial module for Python:
pip install pyserial
Do not confuse with serial
module which is incompatible with this lib.
Usage sample:
fw_unpack.py k5_v2.01.19_publish.bin
Sample output:
CRC OK
Saved decoded firmware to k5_v2.01.19_publish.dec.bin
Saved version info to k5_v2.01.19_publish.ver.bin
Description:
Scripts checks file's CRC then decode it and creates two new files with suffix .dec.bin
and .ver.bin
. If you just want to revere engineer file then only first file is needed. Second one is used by next script fw_pack.py
to put together file ready to upload to device.
Usage sample:
fw_pack.py k5_v2.01.19_publish.dec.bin k5_v2.01.19_publish.ver.bin k5_v2.01.19_reassembled.bin
Sample output:
Saved encoded firmware to k5_v2.01.19_reassembled.bin
Description:
It creates encoded file with correct CRC and version bytes inserted in file. Ready for use with orginal updater.
Arguments:
configmem_read.py <COMx> <address> <len>
Usage sample:
configmem_read.py COM4 0x0F40 8
Sample output:
00010001010101ff
Description:
Script reads contents of configuration memory directly to console.
Arguments:
configmem_write.py <COMx> <address> <hex_payload>
Usage sample:
configmem_write.py COM4 0x0F40 00010001010101ff
Sample output:
PAYLOAD= 00010001010101ff
Description:
Script writes bytes given in payload directly to device. Payload has to be multiply of 8 bytes
Arguments:
reboot_radio.py <COMx>
Usage sample:
reboot_radio.py COM4
Description:
Script just reboots device. Command not produce any output in normal situation. Usefull for example after using configmem_write.py
Arguments:
batt_calibrator.py <COMx> <read | write val0 val1 val2 val3 val4 val5 | calibrate>
To calibrate ADC so battery voltage display more accurately invoke batt_calibrator.py COM1 calibrate
like below:
> batt_calibrator.py COM1 calibrate
Enter voltage from multimeter and press enter:
now follow steps:
- connect radio to PC
- power on radio
- lay your radio with display to the bottom and battery up
- measure voltage on two exposed pad on bottom of the battery
- wait till voltage stabilizes
- write measuder voltage in format
1.23
or1,23
it shoudl not matter - hit enter
- reboot radio
You can backup current calibration values by starting batt_calibrator.py COM1 read
To read more about values and its meaning please refer to documentation.