forked from RalfZim/venus.dbus-fronius-smartmeter
-
Notifications
You must be signed in to change notification settings - Fork 1
/
dbus-discovergy-smartmeter.py
132 lines (113 loc) · 6.13 KB
/
dbus-discovergy-smartmeter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
#!/usr/bin/env python
"""
Created by Ralf Zimmermann ([email protected]) in 2020.
This code and its documentation can be found on: https://github.com/RalfZim/venus.dbus-fronius-smartmeter
Used https://github.com/victronenergy/velib_python/blob/master/dbusdummyservice.py as basis for this service.
Reading information from the Fronius Smart Meter via http REST API and puts the info on dbus.
Changes based on script by user "twanka" from
https://www.photovoltaikforum.com/thread/156974-victron-ess-mit-rasberry-steuern-ohne-gx-ohne-em24-weil-die-leistungsbilanz-scho/?pageNo=15
"""
import dconfig
try:
import gobject # Python 2.x
except:
from gi.repository import GLib as gobject # Python 3.x
import platform
import logging
import sys
import os
import requests # for http GET
try:
import thread # for daemon = True / Python 2.x
except:
import _thread as thread # for daemon = True / Python 3.x
# our own packages
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '../ext/velib_python'))
from vedbus import VeDbusService
path_UpdateIndex = '/UpdateIndex'
class DbusDummyService:
def __init__(self, servicename, deviceinstance, paths, productname='Discovergy Smart Meter', connection='Discovergy Smart Meter service'):
self._dbusservice = VeDbusService(servicename)
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 16) # value used in ac_sensor_bridge.cpp of dbus-cgwacs
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/FirmwareVersion', 0.1)
self._dbusservice.add_path('/HardwareVersion', 0)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Position', 0) #neu hinzugefügt
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], writeable=True, onchangecallback=self._handlechangedvalue)
gobject.timeout_add(15000, self._update) # pause 200ms before the next request
def _update(self):
try:
# meter_url = "http://10.194.65.143/solar_api/v1/GetMeterRealtimeData.cgi?"\
# "Scope=Device&DeviceId=0&DataCollection=MeterRealtimeData"
# meter_r = requests.get(url=meter_url) # request data from the Fronius PV inverter
# meter_data = meter_r.json() # convert JSON data
meter_url = "https://" + dconfig.USER + ":" + dconfig.PASSWORD + "@api.discovergy.com/public/v1/last_reading?meterId=" + dconfig.METER_ID
meter_data = requests.get(meter_url).json() # convert JSON data
meter_consumption = round(meter_data['values']['power']/1000,2)
self._dbusservice['/Ac/Power'] = meter_consumption # positive: consumption, negative: feed into grid
self._dbusservice['/Ac/L1/Voltage'] = round(meter_data['values']['voltage1']/1000)
self._dbusservice['/Ac/L2/Voltage'] = round(meter_data['values']['voltage2']/1000)
self._dbusservice['/Ac/L3/Voltage'] = round(meter_data['values']['voltage3']/1000)
self._dbusservice['/Ac/L1/Current'] = round(meter_data['values']['power1']/meter_data['values']['voltage1'],2)
self._dbusservice['/Ac/L2/Current'] = round(meter_data['values']['power2']/meter_data['values']['voltage2'],2)
self._dbusservice['/Ac/L3/Current'] = round(meter_data['values']['power3']/meter_data['values']['voltage3'],2)
self._dbusservice['/Ac/L1/Power'] = round(float(meter_data['values']['power1'])/1000,2)
self._dbusservice['/Ac/L2/Power'] = round(float(meter_data['values']['power2'])/1000,2)
self._dbusservice['/Ac/L3/Power'] = round(float(meter_data['values']['power3'])/1000,2)
self._dbusservice['/Ac/Energy/Forward'] = round(float(meter_data['values']['power'])/1000,2)
# self._dbusservice['/Ac/Energy/Reverse'] = float(meter_data['values']['EnergyReal_WAC_Sum_Produced'])/1000
logging.info("House Consumption: {:.0f}".format(meter_consumption))
except:
logging.info("WARNING: Could not read from Discovergy Smart Meter")
self._dbusservice['/Ac/Power'] = 0 # TODO: any better idea to signal an issue?
# increment UpdateIndex - to show that new data is available
index = self._dbusservice[path_UpdateIndex] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice[path_UpdateIndex] = index
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
logging.basicConfig(level=logging.DEBUG) # use .INFO for less logging
thread.daemon = True # allow the program to quit
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
# servicename='com.victronenergy.grid',
# deviceinstance=10,
pvac_output = DbusDummyService(
servicename='com.victronenergy.grid.ttyUSB0_di32_mb1',
deviceinstance=40,
paths={
'/Ac/Power': {'initial': 0},
'/Ac/L1/Voltage': {'initial': 0},
'/Ac/L2/Voltage': {'initial': 0},
'/Ac/L3/Voltage': {'initial': 0},
'/Ac/L1/Current': {'initial': 0},
'/Ac/L2/Current': {'initial': 0},
'/Ac/L3/Current': {'initial': 0},
'/Ac/L1/Power': {'initial': 0},
'/Ac/L2/Power': {'initial': 0},
'/Ac/L3/Power': {'initial': 0},
'/Ac/Energy/Forward': {'initial': 0}, # energy bought from the grid
'/Ac/Energy/Reverse': {'initial': 0}, # energy sold to the grid
path_UpdateIndex: {'initial': 0},
})
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
if __name__ == "__main__":
main()