diff --git a/docs/aircraft/a380x/a380x-api/a380x-flight-deck-api.md b/docs/aircraft/a380x/a380x-api/a380x-flight-deck-api.md
index 138a398a6..06a928917 100644
--- a/docs/aircraft/a380x/a380x-api/a380x-flight-deck-api.md
+++ b/docs/aircraft/a380x/a380x-api/a380x-flight-deck-api.md
@@ -163,42 +163,41 @@ Flight Deck: [Calls Panel](../../../pilots-corner/a380x/a380x-briefing/flight-de
Flight Deck: [ELEC Panel](../../../pilots-corner/a380x/a380x-briefing/flight-deck/ovhd/elec.md)
-| Function | API Usage | Values | Read/Write | Type | Remark |
-|:-----------------|:---------------------------------------------------|:-----------|:-----------|:-----------------|:----------------------------------------------------------------------------|
-| BAT {NUM} | A32NX_OVHD_ELEC_BAT_{NUM}_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
-| | A32NX_OVHD_ELEC_BAT_{NUM}_PB_HAS_FAULT | 0..1 | R/W | CUSTOM LVAR | |
-| BAT ESS+APU | A32NX_OVHD_ELEC_BAT_{ESS\|APU}_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
-| | A32NX_OVHD_ELEC_BAT_{ESS\|APU}_PB_HAS_FAULT | 0..1 | R/W | CUSTOM LVAR | |
-| | | | | | |
-| EXT PWR {NUM} | SET_EXTERNAL_POWER | 1..4, 0..1 | - | MSFS EVENT | This event takes 2 parameters - the number of the index 1..4 and OFF/ON=0/1 |
-| | EXTERNAL POWER AVAILABLE:{NUM} | 0..1 | R | MSFS VAR | |
-| | EXTERNAL POWER ON:{NUM} | 0..1 | R | MSFS VAR | |
-| | | | | | |
-| GEN {NUM} | TOGGLE_ALTERNATOR:{NUM} | - | - | SIMCONNECT EVENT | |
-| | GENERAL ENG MASTER ALTERNATOR:{NUM} | 0..1 | R/W | SIMCONNECT VAR | |
-| | A32NX_OVHD_ELEC_ENG_GEN_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| APU GEN | APU_GENERATOR_SWITCH_TOGGLE | 1..2 | - | SIMCONNECT EVENT | |
-| | APU_GENERATOR_SWITCH_SET | 0..1 | - | SIMCONNECT EVENT | |
-| | APU GENERATOR SWITCH | 0..1 | R/W | SIMCONNECT VAR | |
-| | A32NX_OVHD_ELEC_APU_GEN_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| BUS TIE | A32NX_OVHD_ELEC_BUS_TIE_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
-| | A32NX_OVHD_ELEC_BUS_TIE_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| AC ESS FEED | A32NX_OVHD_ELEC_AC_ESS_FEED_PB_IS_NORMAL | 0..1 | R/W | CUSTOM LVAR | |
-| | A32NX_OVHD_ELEC_AC_ESS_FEED_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| AC ESS FEED LOCK | A32NX_OVHD_ELEC_AC_ESS
_FEED_PB_IS_NORMAL_LOCK | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| DRIVE {NUM} | A32NX_OVHD_ELEC_IDG_{NUM}_PB_IS_RELEASED | 0 -> 1 | R/W | CUSTOM LVAR | Cannot be undone - flight restart required |
-| | A32NX_OVHD_ELEC_IDG_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| GALY & CAB | A32NX_OVHD_ELEC_GALY_AND_CAB_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | Current connected with PAX SYS |
-| | A32NX_OVHD_ELEC_GALY_AND_CAB_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
-| | | | | | |
-| COMMERCIAL | A32NX_OVHD_ELEC_COMMERCIAL_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | Currently 1+2 and ELMU are connected |
-| | A32NX_OVHD_ELEC_COMMERCIAL_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | Currently 1+2 and ELMU are connected |
-| | | | | | |
+| Function | API Usage | Values | Read/Write | Type | Remark |
+|:-----------------|:---------------------------------------------------|:---------|:-----------|:-----------------|:-------------------------------------------|
+| BAT {NUM} | A32NX_OVHD_ELEC_BAT_{NUM}_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
+| | A32NX_OVHD_ELEC_BAT_{NUM}_PB_HAS_FAULT | 0..1 | R/W | CUSTOM LVAR | |
+| BAT ESS+APU | A32NX_OVHD_ELEC_BAT_{ESS\|APU}_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
+| | A32NX_OVHD_ELEC_BAT_{ESS\|APU}_PB_HAS_FAULT | 0..1 | R/W | CUSTOM LVAR | |
+| | | | | | |
+| EXT PWR | A32NX_OVHD_ELEC_EXT_PWR_{NUM]_PB_IS_ON | 0..1 | R/W | CUSTOM LVAR | |
+| | A32NX_EXT_PWR_AVAIL:{NUM} | 0|1 | R | MSFS VAR | |
+| | | | | | |
+| GEN {NUM} | TOGGLE_ALTERNATOR:{NUM} | - | - | SIMCONNECT EVENT | |
+| | GENERAL ENG MASTER ALTERNATOR:{NUM} | 0..1 | R/W | SIMCONNECT VAR | |
+| | A32NX_OVHD_ELEC_ENG_GEN_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| APU GEN | APU_GENERATOR_SWITCH_TOGGLE | 1..2 | - | SIMCONNECT EVENT | |
+| | APU_GENERATOR_SWITCH_SET | 0..1 | - | SIMCONNECT EVENT | |
+| | APU GENERATOR SWITCH | 0..1 | R/W | SIMCONNECT VAR | |
+| | A32NX_OVHD_ELEC_APU_GEN_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| BUS TIE | A32NX_OVHD_ELEC_BUS_TIE_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | |
+| | A32NX_OVHD_ELEC_BUS_TIE_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| AC ESS FEED | A32NX_OVHD_ELEC_AC_ESS_FEED_PB_IS_NORMAL | 0..1 | R/W | CUSTOM LVAR | |
+| | A32NX_OVHD_ELEC_AC_ESS_FEED_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| AC ESS FEED LOCK | A32NX_OVHD_ELEC_AC_ESS
_FEED_PB_IS_NORMAL_LOCK | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| DRIVE {NUM} | A32NX_OVHD_ELEC_IDG_{NUM}_PB_IS_RELEASED | 0 -> 1 | R/W | CUSTOM LVAR | Cannot be undone - flight restart required |
+| | A32NX_OVHD_ELEC_IDG_{NUM}_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| GALY & CAB | A32NX_OVHD_ELEC_GALY_AND_CAB_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | Current connected with PAX SYS |
+| | A32NX_OVHD_ELEC_GALY_AND_CAB_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | |
+| | | | | | |
+| COMMERCIAL | A32NX_OVHD_ELEC_COMMERCIAL_PB_IS_AUTO | 0..1 | R/W | CUSTOM LVAR | Currently 1+2 and ELMU are connected |
+| | A32NX_OVHD_ELEC_COMMERCIAL_PB_HAS_FAULT | 0..1 | R | CUSTOM LVAR | Currently 1+2 and ELMU are connected |
+| | | | | | |
### ENG START Panel