-
Notifications
You must be signed in to change notification settings - Fork 2
/
config.pypsaeur.yaml
375 lines (351 loc) · 9.9 KB
/
config.pypsaeur.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
# SPDX-FileCopyrightText: : 2017-2020 The PyPSA-Eur Authors
#
# SPDX-License-Identifier: CC0-1.0
version: 0.2.0
tutorial: false
logging:
level: INFO
format: '%(levelname)s:%(name)s:%(message)s'
summary_dir: results
scenario:
year: [""]
sectors: [E]
simpl: ['']
ll: ['copt']
clusters: [100]
opts: ['3H']
countries: ['AL', 'AT', 'BA', 'BE', 'BG', 'CH', 'CZ', 'DE', 'DK', 'EE', 'ES', 'FI', 'FR', 'GB', 'GR', 'HR', 'HU', 'IE', 'IT', 'LT', 'LU', 'LV', 'ME', 'MK', 'NL', 'NO', 'PL', 'PT', 'RO', 'RS', 'SE', 'SI', 'SK']
snapshots:
start: "2013-01-01"
end: "2014-01-01"
closed: 'left' # end is not inclusive
enable:
prepare_links_p_nom: false
retrieve_databundle: false
build_cutout: false
retrieve_cutout: false
build_natura_raster: false
retrieve_natura_raster: true
electricity:
voltages: [220., 300., 380.]
co2limit: 7.75e+7 # 0.05 * 3.1e9*0.5
co2base: 3.1e+9 # 1 * 3.1e9*0.5
agg_p_nom_limits: data/agg_p_nom_minmax.csv
extendable_carriers:
Generator: []
StorageUnit: [battery, H2]
Store: [] # battery, H2
Link: []
max_hours:
battery: 6
H2: 168
powerplants_filter: false # use pandas query strings here, e.g. Country not in ['Germany']
custom_powerplants: false # use pandas query strings here, e.g. Country in ['Germany']
conventional_carriers: []
# estimate_renewable_capacities_from_capacity_stats:
# # Wind is the Fueltype in ppm.data.Capacity_stats, onwind, offwind-{ac,dc} the carrier in PyPSA-Eur
# Wind: [onwind, offwind-ac, offwind-dc]
# Solar: [solar]
atlite:
nprocesses: 4
cutouts:
europe-2013-era5:
module: era5
xs: [-12., 35.]
ys: [72., 33.]
years: [2013, 2013]
europe-2013-sarah:
module: sarah
resolution: 0.2
xs: [-12., 42.]
ys: [65., 33.]
years: [2013, 2013]
renewable:
onwind:
cutout: europe-2013-era5
resource:
method: wind
turbine: Vestas_V112_3MW
capacity_per_sqkm: 3 # ScholzPhd Tab 4.3.1: 10MW/km^2
# correction_factor: 0.93
corine:
# Scholz, Y. (2012). Renewable energy based electricity supply at low costs:
# development of the REMix model and application for Europe. ( p.42 / p.28)
grid_codes: [12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23,
24, 25, 26, 27, 28, 29, 31, 32]
distance: 1000
distance_grid_codes: [1, 2, 3, 4, 5, 6]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
offwind-ac:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
capacity_per_sqkm: 3
# correction_factor: 0.93
corine: [44, 255]
natura: true
max_depth: 50
max_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
offwind-dc:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
# ScholzPhd Tab 4.3.1: 10MW/km^2
capacity_per_sqkm: 3
# correction_factor: 0.93
corine: [44, 255]
natura: true
max_depth: 50
min_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
solar:
cutout: europe-2013-sarah
resource:
method: pv
panel: CSi
orientation:
slope: 35.
azimuth: 180.
capacity_per_sqkm: 1.7 # ScholzPhd Tab 4.3.1: 170 MW/km^2
# Determined by comparing uncorrected area-weighted full-load hours to those
# published in Supplementary Data to
# Pietzcker, Robert Carl, et al. "Using the sun to decarbonize the power
# sector: The economic potential of photovoltaics and concentrating solar
# power." Applied Energy 135 (2014): 704-720.
correction_factor: 0.854337
corine: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 26, 31, 32]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
hydro:
cutout: europe-2013-era5
carriers: [ror, PHS, hydro]
PHS_max_hours: 6
hydro_max_hours: "energy_capacity_totals_by_country" # one of energy_capacity_totals_by_country,
# estimate_by_large_installations or a float
clip_min_inflow: 1.0
lines:
types:
220.: "Al/St 240/40 2-bundle 220.0"
300.: "Al/St 240/40 3-bundle 300.0"
380.: "Al/St 240/40 4-bundle 380.0"
s_max_pu: 0.7
length_factor: 1.25
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
links:
p_max_pu: 1.0
include_tyndp: true
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
transformers:
x: 0.1
s_nom: 2000.
type: ''
load:
scaling_factor: 1.0
costs:
year: 2030
version: v0.1.0
rooftop_share: 0.5
fill_values:
FOM: 0
VOM: 0
efficiency: 1
investment: 0
lifetime: 25
"discount rate": 0.07
marginal_cost:
solar: 0.01
onwind: 0.015
offwind: 0.015
hydro: 0.
H2: 0.
battery: 0.
emission_prices: # in currency per tonne emission, only used with the option Ep
co2: 0.
solving:
options:
formulation: kirchhoff
load_shedding: false
noisy_costs: true
min_iterations: 4
max_iterations: 6
clip_p_max_pu: 0.01
skip_iterations: true
track_iterations: false
#nhours: 10
solver:
name: gurobi
threads: 4
method: 2 # barrier
crossover: 0
BarConvTol: 1.e-4
FeasibilityTol: 1.e-4
AggFill: 0
PreDual: 0
GURO_PAR_BARDENSETHRESH: 200
# solver:
# name: cplex
# threads: 4
# lpmethod: 4 # barrier
# solutiontype: 2 # non basic solution, ie no crossover
# barrier_convergetol: 1.e-5
# feasopt_tolerance: 1.e-6
plotting:
map:
figsize: [7, 7]
boundaries: [-10.2, 29, 35, 72]
p_nom:
bus_size_factor: 5.e+4
linewidth_factor: 3.e+3
costs_max: 800
costs_threshold: 1
energy_max: 15000.
energy_min: -10000.
energy_threshold: 50.
vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"]
conv_techs: ["OCGT", "CCGT", "Nuclear", "Coal"]
storage_techs: ["hydro+PHS", "battery", "H2"]
load_carriers: ["AC load"]
AC_carriers: ["AC line", "AC transformer"]
link_carriers: ["DC line", "Converter AC-DC"]
tech_colors:
"onwind" : "#235ebc"
"onshore wind" : "#235ebc"
'offwind' : "#6895dd"
'wind': "#74c6f2"
'tsc' : "#4adbc8"
'transmission' : "#ff9000"
'offwind-ac' : "#6895dd"
'offshore wind' : "#6895dd"
'offshore wind ac' : "#6895dd"
'offwind-dc' : "#74c6f2"
'offshore wind dc' : "#74c6f2"
"hydro" : "#08ad97"
"hydro+PHS" : "#08ad97"
"PHS" : "#08ad97"
"hydro reservoir" : "#08ad97"
'hydroelectricity' : '#08ad97'
"ror" : "#4adbc8"
"run of river" : "#4adbc8"
'solar' : "#f9d002"
'solar PV' : "#f9d002"
'solar thermal' : '#ffef60'
'biomass' : '#0c6013'
'solid biomass' : '#06540d'
'biogas' : '#23932d'
'waste' : '#68896b'
'geothermal' : '#ba91b1'
"OCGT" : "#d35050"
"OCGT marginal" : "#d35050"
"OCGT-heat" : "#d35050"
"gas boiler" : "#d35050"
"gas boilers" : "#d35050"
"gas boiler marginal" : "#d35050"
"gas-to-power/heat" : "#d35050"
"gas" : "#d35050"
"natural gas" : "#d35050"
"CCGT" : "#b20101"
"CCGT marginal" : "#b20101"
"Nuclear" : "#ff9000"
"Nuclear marginal" : "#ff9000"
"nuclear" : "#ff9000"
"coal" : "#707070"
"Coal" : "#707070"
"Coal marginal" : "#707070"
"lignite" : "#9e5a01"
"Lignite" : "#9e5a01"
"Lignite marginal" : "#9e5a01"
"Oil" : "#262626"
"oil" : "#262626"
"H2" : "#ea048a"
"hydrogen storage" : "#ea048a"
"Sabatier" : "#a31597"
"methanation" : "#a31597"
"helmeth" : "#a31597"
"DAC" : "#d284ff"
"co2 stored" : "#e5e5e5"
"CO2 sequestration" : "#e5e5e5"
"battery" : "#b8ea04"
"battery storage" : "#b8ea04"
"Li ion" : "#b8ea04"
"BEV charger" : "#e2ff7c"
"V2G" : "#7a9618"
"transport fuel cell" : "#e884be"
"retrofitting" : "#e0d6a8"
"building retrofitting" : "#e0d6a8"
"heat pumps" : "#ff9768"
"heat pump" : "#ff9768"
"air heat pump" : "#ffbea0"
"ground heat pump" : "#ff7a3d"
"power-to-heat" : "#a59e7c"
"power-to-gas" : "#db8585"
"power-to-liquid" : "#a9acd1"
"Fischer-Tropsch" : "#a9acd1"
"resistive heater" : "#aa4925"
"water tanks" : "#401f75"
"hot water storage" : "#401f75"
"hot water charging" : "#351c5e"
"hot water discharging" : "#683ab2"
"CHP" : "#d80a56"
"CHP heat" : "#d80a56"
"CHP electric" : "#d80a56"
"district heating" : "#93864b"
"Ambient" : "#262626"
"Electric load" : "#f9d002"
"electricity" : "#f9d002"
"Heat load" : "#d35050"
"heat" : "#d35050"
"Transport load" : "#235ebc"
"transport" : "#235ebc"
"lines" : "#70af1d"
"transmission lines" : "#70af1d"
"AC-AC" : "#70af1d"
"AC line" : "#70af1d"
"links" : "#8a1caf"
"HVDC links" : "#8a1caf"
"DC-DC" : "#8a1caf"
"DC link" : "#8a1caf"
"gini" : "#b06555"
nice_names:
OCGT: "Open-Cycle Gas"
CCGT: "Combined-Cycle Gas"
offwind-ac: "Offshore Wind (AC)"
offwind-dc: "Offshore Wind (DC)"
offwind: "Offshore Wind"
onwind: "Onshore Wind"
solar: "Solar"
PHS: "Pumped Hydro Storage"
hydro: "Reservoir & Dam"
battery: "Battery Storage"
H2: "Hydrogen Storage"
lines: "Transmission lines"
ror: "Run of river"
transmission: "Transmission"
tsc: "Total System Cost"
wind: "Any Wind"
gini: "Gini Index"
nice_names_n:
OCGT: "Open-Cycle\nGas"
CCGT: "Combined-Cycle\nGas"
offwind-ac: "Offshore\nWind (AC)"
offwind-dc: "Offshore\nWind (DC)"
offwind: "Offshore\nWind"
onwind: "Onshore\nWind"
battery: "Battery\nStorage"
H2: "Hydrogen\nStorage"
lines: "Transmission"
transmission: "Transmission"
ror: "Run of\nriver"
solar: "Solar"
PHS: "Pumped Hydro\nStorage"
hydro: "Reservoir\n& Dam"
tsc: "Total System\nCost"
wind: "Any\nWind"