You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This property indicates the ON/OFF status. If the ON/OFF status is ON, this value is true, otherwise false.
Installation location
EPC: 0x81
Property
Type
Description
code
Number
This property indicates the installation location as a code. See the description below for details.
desc
String
The installation location.
The location code map is as follow. Each code is shown as binary representation:
Code
Location (English)
Location (Japanese)
0b00001
Living room
居間、リビング
0b00010
Dining room
食堂、ダイニング
0b00011
Kitchen
台所、キッチン
0b00100
Bathroom
浴室、バス
0b00101
Lavatory
トイレ
0b00110
Washroom/changing room
洗面所、脱衣所
0b00111
Passageway
廊下
0b01000
Room
部屋
0b01001
Stairway
階段
0b01010
Front door
玄関
0b01011
Storeroom
納戸
0b01100
Garden/perimeter
庭、外周
0b01101
Garage
車庫
0b01110
Veranda/balcony
ベランダ、バルコニー
0b01111
Others
その他
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Standard version information
EPC: 0x82
Property
Type
Description
release
String
This property indicates the release number of the corresponding Appendix. This value will be an uppercase alphabet (e.g. "H").
The value of release must be an ASCII character.
Identification number
EPC: 0x83
Property
Type
Description
code
Number
This property indicates the manufacturer code as an integer.
uid
String
This property indicates the unique ID defined by the manufacturer as hexadecimal representation.
The value of the code property must be an integer in the range of 0x000000 to 0xFFFFFF. The byte length of the value of the uid property must be equal to or less than 13 bytes.
This property indicates the instantaneous power consumption of the device in watts (W).
The value of the power property must be an integer in the range of 0 to 65533 (W).
Measured cumulative power consumption
EPC: 0x85
Property
Type
Description
power
Number
This property indicates the cumulative power consumption of the device in units of kWh.
The value of the power property must be an float in the range of 0 to 999,999.999 (kWh).
Manufacturer's fault code
EPC: 0x86
Property
Type
Description
manufacturer
Number
This property indicates the manufacturer code as an integer.
fault
String
This property indicates the manufacturer-defined fault code as hexadecimal representation.
The value of the manufacturer property must be an integer in the range of 0x000000 to 0xFFFFFF. The byte length of the value of the fault property must be equal to or less than 221 bytes.
Current limit setting
EPC: 0x87
Property
Type
Description
limit
Number
This property indicates the current limit setting (0–100%).
The value of the limit property must be an integer in the range of 0 to 100 (%).
Fault status
EPC: 0x88
Property
Type
Description
fault
Boolean
This property indicates whether a fault has occurred or not. If a fault has occurred, this value is true, otherwise false.
Fault content
EPC: 0x89
Property
Type
Description
code1
Number
Fault description code (Higher-order byte)
code2
Number
Fault description code (Lower-order byte)
desc
String
Fault description
The Fault content is expressed using 2 bytes (code1 and code2).
Manufacturer code
EPC: 0x8A
Property
Type
Description
code
Number
This property indicates the manufacturer code as an integer.
The value of the code property must be an integer in the range of 0x000000 to 0xFFFFFF.
Business facility code
EPC: 0x8B
Property
Type
Description
code
Number
This property indicates the 3-byte business facility code defined by each manufacturer.
The value of the code property must be an integer in the range of 0x000000 to 0xFFFFFF.
Product code
EPC: 0x8C
Property
Type
Description
code
String
This property indicates the product code defined by each manufacturer.
The value of the code property must be an ASCII text. The number of characters is equal to or less than 12.
Production number
EPC: 0x8D
Property
Type
Description
number
String
This property indicates the production number defined by each manufacturer.
The value of the code property must be an ASCII text. The number of characters is equal to or less than 12.
Production date
EPC: 0x8E
Property
Type
Description
date
String
This property indicates the production date in the "YYYY-MM-DD" format.
Power-saving operation setting
EPC: 0x8F
Property
Type
Description
mode
Boolean
This property indicates whether the device is operating in power-saving mode. If in power-saving mode, this value is true, otherwise false.
Remote control setting
EPC: 0x93
Property
Type
Description
code
Number
This property indicates whether remote control is through a public network or not as a code.
desc
String
The description of the code.
The value of code must be either 0x41, 0x42, 0x61, or 0x62. The code map is as follow. Each code is shown as hexadecimal representation:
Code
Description (English)
Description (Japanese)
0x41
Remote control not through a public network
公衆回線未経由操作
0x42
Remote control through a public network
公衆回線経由操作
0x61
Remote control is now allowed
公衆回線経由の操作不可
0x62
Remote control is allowed
公衆回線経由の操作可能
If you only read this EDT object, you don't need to know the code map above. It is enough to see the value of the desc property.
If you want to create an ECHONET Lite packet to send, the desc property is not required.
Current time setting
EPC: 0x97
Property
Type
Description
hm
String
This property indicates the current time ("HH:MM" format).
Current date setting
EPC: 0x98
Property
Type
Description
ymd
String
This property indicates the current date ("YYYY-MM-DD" format).
Power limit setting
EPC: 0x99
Property
Type
Description
limit
Number
This property indicates the power limit setting in watts (W).
The value of the limit property must be a integer in the range of 0 to 65535 (W).
Cumulative operating time
EPC: 0x9A
This property indicates the cumulative number of days, hours, minutes or seconds for which the device has operated, using 1 byte for the unit and 4 bytes for the time.
Property
Type
Description
unit
Number
This property indicates the unit code.
elapsed
Number
This property indicates the cumulative operating time.
The value of unit must be an integer 1, 2, 3, or 4. The code map is as follow. Each code is shown as decimal representation:
Code
Unit (English)
Unit (Japanese)
1
Second
秒
2
Minute
分
3
Hour
時
4
Day
日
The value of elapsed must be an integer in the range of 0 to 4294967295 (0xFFFFFFFF).
If the value of the unit is 3 and the value of the elapsed is 23, the cumulative operating time is 23 hours.
SetM property map
EPC: 0x9B
Property
Type
Description
list
Array
This property indicates a list of EPCs which the device supports as SetM.
GetM property map
EPC: 0x9C
Property
Type
Description
list
Array
This property indicates a list of EPCs which the device supports as GetM.
Status change announcement property map
EPC: 0x9D
Property
Type
Description
list
Array
This property indicates a list of EPCs which the device supports as Status change announcement.
Set property map
EPC: 0x9E
Property
Type
Description
list
Array
This property indicates a list of EPCs which the device supports as Set.
Get property map
EPC: 0x9F
Property
Type
Description
list
Array
This property indicates a list of EPCs which the device supports as Get.