You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
In bandwidth_sampler.cc, within OnPacketAcknowledgedInner, the following ERROR is logged. Could you please explain in detail why this is possible? Additionally, I noticed a TODO in the code—is it related to this issue? Could you please describe all potential causes that might trigger this?
// During the slope calculation, ensure that ack time of the current packet is
// always larger than the time of the previous packet, otherwise division by
// zero or integer underflow can occur.
if (ack_time <= a0.ack_time) {
// TODO(wub): Compare this code count before and after fixing clock jitter
// issue.
if (a0.ack_time == sent_packet.sent_time()) {
// This is the 1st packet after quiescense.
QUIC_CODE_COUNT_N(quic_prev_ack_time_larger_than_current_ack_time, 1, 2);
} else {
QUIC_CODE_COUNT_N(quic_prev_ack_time_larger_than_current_ack_time, 2, 2);
}
QUIC_LOG_EVERY_N_SEC(ERROR, 60)
<< "Time of the previously acked packet:"
<< a0.ack_time.ToDebuggingValue()
<< " is larger than the ack time of the current packet:"
<< ack_time.ToDebuggingValue()
<< ". acked packet number:" << packet_number
<< ", total_bytes_acked_:" << total_bytes_acked_
<< ", overestimate_avoidance_:" << overestimate_avoidance_
<< ", sent_packet:" << sent_packet;
return BandwidthSample();
}
The text was updated successfully, but these errors were encountered:
In bandwidth_sampler.cc, within OnPacketAcknowledgedInner, the following ERROR is logged. Could you please explain in detail why this is possible? Additionally, I noticed a TODO in the code—is it related to this issue? Could you please describe all potential causes that might trigger this?
The text was updated successfully, but these errors were encountered: