From 446f5d91ecc75d702ce7e3387de4fb5aec324d39 Mon Sep 17 00:00:00 2001 From: Bernhard Kirchen Date: Wed, 10 Apr 2024 21:15:54 +0200 Subject: [PATCH] fix hysteresis hint texts --- webapp/src/locales/de.json | 2 +- webapp/src/locales/en.json | 2 +- webapp/src/locales/fr.json | 2 +- 3 files changed, 3 insertions(+), 3 deletions(-) diff --git a/webapp/src/locales/de.json b/webapp/src/locales/de.json index a56d5050e..13808ec58 100644 --- a/webapp/src/locales/de.json +++ b/webapp/src/locales/de.json @@ -606,7 +606,7 @@ "TargetPowerConsumption": "Angestrebter Netzbezug", "TargetPowerConsumptionHint": "Angestrebter erlaubter Stromverbrauch aus dem Netz. Wert darf negativ sein.", "TargetPowerConsumptionHysteresis": "Hysterese", - "TargetPowerConsumptionHysteresisHint": "Neu berechnetes Limit nur dann an den Inverter senden, wenn es vom zuletzt gesendeten Limit um mindestens diesen Betrag abweicht.", + "TargetPowerConsumptionHysteresisHint": "Neu berechnetes Limit nur dann an den Inverter senden, wenn es vom zurückgemeldeten Limit um mindestens diesen Betrag abweicht.", "LowerPowerLimit": "Minmales Leistungslimit", "LowerPowerLimitHint": "Dieser Wert muss so gewählt werden, dass ein stabiler Betrieb mit diesem Limit möglich ist. Falls der Wechselrichter nur mit einem kleineren Limit betrieben werden könnte, wird er stattdessen in Standby versetzt.", "BaseLoadLimit": "Grundlast", diff --git a/webapp/src/locales/en.json b/webapp/src/locales/en.json index 6599ce797..727eea19a 100644 --- a/webapp/src/locales/en.json +++ b/webapp/src/locales/en.json @@ -612,7 +612,7 @@ "TargetPowerConsumption": "Target Grid Consumption", "TargetPowerConsumptionHint": "Grid power consumption the limiter tries to achieve. Value may be negative.", "TargetPowerConsumptionHysteresis": "Hysteresis", - "TargetPowerConsumptionHysteresisHint": "Only send a newly calculated power limit to the inverter if the absolute difference to the last sent power limit matches or exceeds this amount.", + "TargetPowerConsumptionHysteresisHint": "Only send a newly calculated power limit to the inverter if the absolute difference to the last reported power limit exceeds this amount.", "LowerPowerLimit": "Minimum Power Limit", "LowerPowerLimitHint": "This value must be selected so that stable operation is possible at this limit. If the inverter could only be operated with a lower limit, it is put into standby instead.", "BaseLoadLimit": "Base Load", diff --git a/webapp/src/locales/fr.json b/webapp/src/locales/fr.json index 0f5946f87..ae888850f 100644 --- a/webapp/src/locales/fr.json +++ b/webapp/src/locales/fr.json @@ -694,7 +694,7 @@ "TargetPowerConsumption": "Target Grid Consumption", "TargetPowerConsumptionHint": "Grid power consumption the limiter tries to achieve. Value may be negative.", "TargetPowerConsumptionHysteresis": "Hysteresis", - "TargetPowerConsumptionHysteresisHint": "Only send a newly calculated power limit to the inverter if the absolute difference to the last sent power limit matches or exceeds this amount.", + "TargetPowerConsumptionHysteresisHint": "Only send a newly calculated power limit to the inverter if the absolute difference to the last reported power limit exceeds this amount.", "LowerPowerLimit": "Minimum Power Limit", "LowerPowerLimitHint": "This value must be selected so that stable operation is possible at this limit. If the inverter could only be operated with a lower limit, it is put into standby instead.", "BaseLoadLimit": "Base Load",