Skip to content
MalteSchm edited this page Feb 18, 2024 · 9 revisions

Hoymiles inverter selection

Recommended are HM inverters with a single power stage / MPPT tracker. Rationale:

The HM Hoymiles inverter series are build using 1 or 2 independent power stages / MPPT trackers. The larger models use two solar modules for each power stage / MPPT tracker. A simplified model of a 4 channel inverter is shown in the diagram below. This diagram shows the 4 channels, the 2 independent power stages (denoted as R Last) and the shunts (denoted as R Shunt) for the 4 channels. The shunts are used for current measurement and power control such that the requested power is delivered by the two power stages.

29809-image

When connected to a battery the inverter will have all + and - connections connected. There will be small resistance differences in the shunts and the cables / plugs used to make this connection. This causes current to flow over the ground connection between both power stages which will provide an incorrect current reading to the power stages. This will lead to unequal power generation in both stages.

Does HOYMILES overheat?

According to Hoymiles, the inverters have a: Derating triggering temperature of 85°C Derating factor of 14% Shutdown temperature of 90°C **Restart temperature of 85°C ** Restart interval of 0 (meaning that, once it shuts down, a Hoymiles inverter will continually check to see if it has reached the required restart temperature, allowing the inverter to begin converting power as fast as possible)

The graph below shows the power reduction relative to the temperature of these models of Hoymiles microinverters. As you can see, power drops rapidly once the internal temperature of the microinverter rises past 90°C. However, once the inverter reaches the restart temperature of 85°C once more, you can see that the power immediately rises back up to 100% — no waiting around for the power to gradually rebuild once the inverter restarts. Temperature reaction

Earth the Hoymiles?

(to be translated) Es müssen alle Gehäuseteile der Anlage auf eine Erdungsschiene geführt werden, sowie die Erdungsanschlüsse der Überspannungsableiter. Beim Hoymiles Wechselrichter gibts auch eine Schraube für die Erdung. Die Erdungsschiene wird dann mit der Erdung verbunden, im Haus wäre das die Potentialausgleichsschiene. Die Plus- und Minuspole sowohl der Batterie/Akku als auch der Solar-Panel-Leitungen werden nicht geerdet - sie sollen potentialfrei sein!

All housing parts of the system must be connected to an earthing bar, as well as the earthing connections of the surge arresters. The Hoymiles inverter also has a screw for earthing. The earthing bar is then connected to the earthing, in the house this would be the potential equalisation bar. The positive and negative poles of both the battery and the solar panel cables are not earthed - they should be potential-free!

Clone this wiki locally