Notifications
You must be signed in to change notification settings - Fork 66
Power Meter
Power Meter supports 6 different providers:
- SDM 1 phase (SDM120/220/230)
- SDM 3 phase (SDM72/630)
- HTTP(S)+JSON
- SML (OBIS 16.7.0)
- SMA HomeManager 2.0
- MQTT
- Tibber Pulse (via Tibber Bridge) (Work in Progress)
Shelly 3EM: Working configuration:
Discussion: #331
- Shelly PRO 3EM #364
- Tasmota #360 #339 #191 #412
- powerfox #165
- simple JSON Array #191
- Volkszähler #359
- FHEM #335
Tasmota returns values and names based on the definitions you put in the script.
The standard command http://192.168.xxx.xxx/cm?cmnd=status%208 (where 192.168.xxx.xxx is the IP Adress of your Tasmota) will return the values that are available, for example:
{ "StatusSNS": { "Time": "2023-12-10T20:17:41", "Wohnung": { "server_id": "0a01415041010557ff7d", "total_kwh": 819.9, "export_total_kwh": 251.48, "aktuelle_Wirkleistung": 557, "freq": 50, "amp_p1": 0.98, "amp_p2": 0.45, "amp_p3": 1.46, "curr_w_p1": 184, "curr_w_p2": 82, "curr_w_p3": 289, "volt_p1": 240.8, "volt_p2": 240.9, "volt_p3": 241.3, "phase_angle_l2_l1": 238, "phase_angle_l3_l1": 118, "phase_angle_p1": 330, "phase_angle_p2": 325, "phase_angle_p3": 333 } } }
In this case, the value aktuelle_Wirkleistung is the one we need.
In order to extract the correct value, you need to notice the number of curly brackets { and the titles
Based on the example above: {"StatusSNS": {"Wohnung": {"aktuelle_Wirkleistung": 557
Subsequently the JSON Pfad you need to enter is:
StatusSNS/Wohnung/aktuelle_Wirkleistung
Some users have mentioned that their Tasmota report spikes from time to time https://github.com/helgeerbe/OpenDTU-OnBattery/discussions/851
There is a solution to it: Changing the descriptor to send with every change of values:
Tasmota Teleperiod is configurable between 10-300 Seconds. As Standart is 300: Tasmota sends every 5 Minutes. You can go as low as 10 Seconds.
If you need faster than 10 seconds, you have to change the descriptor, the information will be send with every change of values
1,77070100100700ff@1,P,W,P,18
the last entry is the number of digits + an optional flag to send the value as fast as possible code = 16 so 16+2 = 18 means 2 digits + fast send
Example:
If your line looks like this: 1,77070100100700ff@1,P,W,P,0
add 0+16=16 and change it to: 1,77070100100700ff@1,P,W,P,16
- Tasmota and MQTT, push seperate values with rules #344
Power Meter uses the same MQTT Server you have defined under Settings-> MQTT Settings
Then, go to Settings -> Power Meter and you can define up to three topics.
There is an example in every line but keep in mind, these are inactive. If you need exactly the same, you have to re-type it yourself.
Important: For the time being, the MQTT Functionality is not as advanced as with HTTP(s)+JSON
The Topic you choose, must deliver a single value. No JSON Objects, no Strings can be used.
If you are not sure what Data your MQTT Server receives, monitor its log for a while. For example:
None of these Topics (List from MQTT Server) will work:
The first three Topics below will work:
IF you have problems seeing the data you expect in Live View, it is useful to go to Info-> Console
Messages like this imply that your MQTT Server refused the connection
17:35:55.099 Connecting to MQTT..
17:35:56.209 PowerMeterClass: TotalPower: 0.00
17:35:58.109 Disconnected from MQTT.
17:35:58.168 Disconnect reason:TCP_DISCONNECTED
Tibber Pulse (Work in Progress)
A member has built upon the "HTTP(S) + JSON" Power Meter to support the Tibber Pulse. The current power drawn from the grid is fetched using the local web server from the Tibber Bridge. No external requests through the internet (Tibber API) required.
To ensure that the consumption values from the Tibber Pulse are always up-to-date and can be read out independently of an Internet connection, the local web server of the Tibber Bridge must be permanently activated.
Activate the Tibber Bridge web server permanently:
- Make a note of the password on the bridge (it is on the QR code), e.g. ABCD-AA11.
- Pull out the bridge, plug it in for approx. 1-2 seconds, pull it out and plug it in again.
- The ring should now light up green. (No worries, no settings will be lost!).
- Connect to the WLAN network 'TibberBridge', the password to be entered is the password noted above.
- Once the connection has been established, open http://10.133.70.1/params/ in your browser.
- The user name is 'admin' and the password is as noted at the beginning.
- Enter the value 'true' at the bottom of the 'webserver_force_enable' attribute and then 'Store params to flash'.
- Unplug and plug in again. The Tibber Bridge will now start up normally again.
As soon as the Tibber-Bridge web server has been activated, the credentials can be added in the power meter settings.
'http://{IP}/data.json?node_id=1' must be entered as the URL.
'{IP}' is to be replaced with the IP of the bridge, e.g. 'http://{IP}/data.json?node_id=1'
Username is 'admin' and the Password here is also the password on the bridge.
The SML power meter requires the rx pin to be set.
The SDM power meter requires the rx and tx pins are set. The "dere" pin pin is optional and if set, this pin controls the driver enable and receiver enable pins of the RS485 transceiver (the SDM library handles this pin).
in your pin_mapping.json, you need to add a powermeter object like this:
[
{
"name": "My Board",
...
"powermeter": {
"rx": <num>,
"tx": <num>,
"dere": <num>
},
...
}
]
set pin-number to -1 for unused pins .
- Home
- FAQ
- First-Time Installation
- Device Profiles (Pin Config)
- Upgrade from OpenDTU
- Getting Help
- Hilfe erhalten
- Builds & Examples
- ESP32 Versions and Memory
- Victron MPPT solar charger
- VE.Direct
- Victron Smartshunt
- Victron Smart Battery Sense
- Warning on Victron MPPT 100/20
- Pylontech battery
- Pytes battery
- Huawei AC PSU
- SBS Unipower Battery
- Jikong JK BMS
- HOYMILES
- Einschaltstrombegrenzung für Balkonkraftwerke - Inrush current limiter
- Live View
- Farbe des Wechselrichterfensters
- Power Meter
- Dynamic Power Limiter
- Dynamic Power Limiter ‐ (Full) Solar‐Passthrough
- Dynamic Power Limiter Limitations
- DC Voltage ‐ Load correction factor
- Battery
- Battery-Tipps
- 24V Battery issues with Hoymiles
- Home Assistant
- Grafana Dashboard
- XXL Balkonkraftwerk 1500 Watt und mehr! Worauf Ihr achten solltet!
- Wie gefährlich kann ein Balkonkraftwerk werden (FI‐Schutzschalter)
- Hardware Purchase Tipp
- Fan speed controller ‐ add temperature sensing to any fan
- Cable length(s) between battery and inverter
- Kabellänge(n) zwischen Batterie und Wechselrichter
- Diodes ‐ Bypass vs. Blocking Diodes
- Impact of high start-currents to the inverter
- Making Cables for your HOYMILES‐CAUTION