Resolved Issues

The following table lists the resolved issues for HPE CSI Driver for Kubernetes v2.0.0.

ID Component Title Resolution
BZ-134925 csi.k8s Disable NodeGetVolumeStats capability Set the parameter disableNodeGetVolumeStats to true at the time of deployment.

The following table lists the resolved issues for HPE Primera/3PAR CSP for HPE CSI Driver release 2.0.0.

ID Component Title Resolution
BZ-134504 csi.k8s Suboptimal attach/detach performance when all FC ports are auto-discovered and used for multipathing For a higher end primera array, there could be several FC ports available for use with multipathing. By default the CSP auto-discovers all available FC ports and uses them for multipathing. This increases the time taken for attach/detach operations significantly. To address this, a new parameter fcPortsList is added in Storageclass. This will be applicable only for newer volumes that are created.

Known Issues

The following table lists the known issues for HPE CSI Driver for Kubernetes v2.0.0. Please note that, Known Issues from previous releases are still applicable with suggested workarounds, if they are not part of Resolved Issues above.

ID Component Title Description Workaround
CON-2013 csi.k8s "btrfs" filesystem limitation - it does not use Inodes as other filesystems Inode metrics as part of NodeGetVolumeStats are not present for btrfs filesystem. https://unix.stackexchange.com/questions/525637/debian-btrfs-filesystem-shows-a-total-of-zero-inodes-total-zero-used-zero-free None
CON-2109 csi.k8s Scale setup with mixed workloads may bottleneck the CSP In a large scale environment when the PVCs and associated pods are created at once, it creates a large number of requests to the CSP. Create the PVCs prior to creating the workload to lessen the load on the CSP.
CON-2116 csi.k8s Volume with xfs filesystem created on Ubuntu does not mount on CentOS xfs Filesystem created on Ubuntu 20.04 fails to mount on another CentOS worker node with error wrong fs type, bad option, bad superblock. None
CON-2121 csi.k8s Ephemeral volumes are not deleted after node shutdown Ephemeral volumes are created as part of NodePublish. On node shutdown if the pods are deleted after MaxWaitForUnmount, the scrubber does not clean up orphan volumes for which there is no associated pod. None

The following table lists the known issues for HPE Alletra 6000 and Nimble CSP for HPE CSI Driver release 2.0.0

ID Component Title Description Workaround
CON-1290 csi.k8s Incorrect secret to access PVC/POD created by different tenant user will leave orphan objects If incorrect secrets are passed to manage a PVC which was created by a different tenant. With access restrictions, the Nimble CSP will not be able to find the volume created by another tenant. The PVC will be successfully removed on cluster but does not delete the volume on the Storage System None
CON-1495 csi.k8s Tenant users have access to volumes created by different user on Nimble GUI Multi-tenancy feature is only supported through CSI/ and Alletra 600 and Nimble CSP and management of tenant objects through Nimble GUI is not supported. None
CON-1502 csi.k8s Multi-tenancy: Volume Attach with CHAP User fails CSI Driver supports only 1 CHAP User per cluster. Since tenant user has restricted access of CHAP Users, more than 1 tenant with CHAP User is not supported. None
CON-1573 csi.k8s importVolume using tenant secret for downstream array ImportVolume on downstream array does not work with tenant user ImportVolume using admin user secret
CON-1821 csi.k8s Not able to create Initiator group for long hostname initiator group name is limited to 60 characters. Limit the hostname to lesser than 60 characters
CON-2141 csi.k8s Pod deletion takes a lot of time with Iscsi Volume Scoped Target On a scale setup with large number of pods, logout of Volume Scoped Iscsi Targets and device deletion takes a long time. Use Iscsi Group Scoped Target on a scale setup.

The following table lists the known issues for HPE Alletra 9000 and Primera/3PAR CSP for HPE CSI Driver release 2.0.0

ID Component Title Description Workaround