Poor accuracy usually results from poor calibration, improper data feed to
the Madgwick fusion filter, or crappy sensors.
Are you sending the properly scaled and calibrated sensor data to the
Madgwick filter in NED or ENU order?
What does "totally wild" mean?
If you choose Ax pointing North, select the other 8 sensor data in NED
order and point the device such that Ax aligns with North and leave it flat
and motionless, do you see:
0, 0, 0, 1 for the quaternion and 0, 0, 1 for the accel, 0, 0, 0 for the
gyro and Mx, My, Mz that correspond to what the USGS says you should expect
for your location?
Now if you rotate the device 90 degrees and leave it flat and
motionless...what do you see?
…On Sun, Aug 29, 2021 at 8:09 AM nodeMike ***@***.***> wrote:
Hello,
I've encountered huge issue during (lengthy) development of my device.
When Im running madgwick without magnetometer readings, the orientation
quaternions is pretty accurate, however obviously prone to drift (not
huge). However if I use magnetometer readings in sensor fusion, the
quaternion goes totally wild. It looks like magnetometer readings
completely override gyro/acc measurements, and somehow "forces" orientation
(if I rotate module, it goes back to specific, somehow, predetermined
orientation as if magnetometer overriden acc/gyro after some cycles). Axes
of sensors are aligned correctly (im using ICM-20948 chip, and aligned axes
according to documentation, and many other ICM-20948 repositories I've
found). When not using magnetometer readings, calculated quaternion is
correct, so it narrows everything down to magnetometer readings. I've even
tried all possible combinations of X,Y,Z (including inverting signs of
axes), without any success. Magnetometer is calibrated with "Magneto" app,
and the results seems to be good:
[image: Zrzut ekranu 2021-08-29 16 20 45]
<https://user-images.githubusercontent.com/73556998/131255214-ea6f30ae-9f9a-4016-8d27-13d2bad49bce.png>
Im struggling with this issue for days, and I thought maybe someone here
could put me out of misery... I've also tested few different implementation
of both Madgwick and Mahony filters, yet the same issue occurs. Am I
missing something?
Thanks!
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#467>, or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKR2V4ATTX6CPTOKEOTT7JESHANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
If the heading swings rapidly to a fixed point no matter the orientation of
the device this sounds to me like the mag data is way wrong despite the
good look of your calibration surface. The mag offset biases are huge. So
if you have such a locally distorted mag field due to unavoidable
mechanical constraints then you might not be able to use 9 DoF fusion here.
Or you will have to find a way to correct for the ginormous local field. I
would think the usual hard iron correction would work but if the local
field is much larger than the Earth's field components you might never see
any change...i.e., always points to the same heading...
This is not wild, it is more or less what one would expect by putting a
gigantic magnet next to an IMU.
…On Sun, Aug 29, 2021 at 1:19 PM nodeMike ***@***.***> wrote:
Poor accuracy usually results from poor calibration [...]
Picture I've sent in previous message presents a before/after of
magnetometer calibration. "Before" a significant both hard and soft iron
distortions can be observed, caused by mechanical (sadly, crucial) elements
next to PCB board. After implementing a calibration proposed by app called
"Magneto 1.2", the results seems to be ok (however final output seems to
contradict it).
Example values and calibration process of magnetometer:
float biases[3];
float scaleFactorTop[3];
float scaleFactorMid[3];
float scaleFactorDown[3];
biases[0] = 380.369407f;
biases[1] = 262.456571f;
biases[2] = -819.497395f;
scaleFactorTop[0] = 1.246254f;
scaleFactorTop[1] = -0.036161f;
scaleFactorTop[2] = 0.213955f;
scaleFactorMid[0] = -0.036161f;
scaleFactorMid[1] = 1.306548f;
scaleFactorMid[2] = 0.074080f;
scaleFactorDown[0] = 0.213955f;
scaleFactorDown[1] = 0.074080f;
scaleFactorDown[2] = 0.998964f;
float Xm_off = magRawReadings.x - biases[0];
float Ym_off = magRawReadings.y - biases[1];
float Zm_off = magRawReadings.z - biases[2];
target->x = scaleFactorTop[0] * Xm_off + scaleFactorTop[1] * Ym_off + scaleFactorTop[2] * Zm_off;
target->y = scaleFactorMid[0] * Xm_off + scaleFactorMid[1] * Ym_off + scaleFactorMid[2] * Zm_off;
target->z = scaleFactorDown[0] * Xm_off + scaleFactorDown[1] * Ym_off + scaleFactorDown[2] * Zm_off;
target->x *= sensorConfig->magSensitivity;
target->y *= sensorConfig->magSensitivity;
target->z *= sensorConfig->magSensitivity;
Results after the calibrations seems to be pretty "round and centered",
which would be a desired outcome. Madgwick inputs of magnetometer (at least
in implementation used by me) are also normalized, so I'm pretty sure the
sensitivity values could be omitted (however they are picked according to
the documentation).
Poor accuracy usually results from [...] improper data feed to the
Madgwick fusion filter [...]
I would say that I can vouch for accelerometer and gyro data feed. Without
magnetometer data, the output of fusion filter seems to be great and very
precise. With magnetometer - I've tested all 48 possible combinations of
order and signs, without success.
Poor accuracy usually results from [...] crappy sensors.
Im not in position to judge, however usage of ICM-20948 (with AK09916 as
magnetometer) doesnt seem to be that bad of a choice. Also, I'm positive
that chip damage is not an issue (few devices acting the same). It's not an
issue of slight deviation, but total chaos (further described).
Are you sending the properly scaled and calibrated sensor data to the
Madgwick filter in NED or ENU order?
I believe so. Orientation of axes is described by documentation:
[image: Zrzut ekranu 2021-08-29 21 57 29]
<https://user-images.githubusercontent.com/73556998/131263717-e30189b3-f555-412f-b2ac-3648b95d830b.png>
I reverse Y and Z axes value at the level of ICM-20948 driver (yes, they
are little-endian):
x = (i2cReadBuffer[1] << 8) + i2cReadBuffer[0];
y = -((i2cReadBuffer[3] << 8) + i2cReadBuffer[2]);
z = -((i2cReadBuffer[5] << 8) + i2cReadBuffer[4]);
After this operation, all axes should be aligned (acc/gyro/mag). Then I've
tried feeding data in NED (Y, X, -Z), ENU (-X, Y, Z) and NWU (Y, X, Z).
None of mentioned fixed issues.
What does "totally wild" mean?
When I start feeding data to filter, the quaternion rotates crazily from
the original position. E. g. almost instant 90 rotation in "x" axis
(depends on the way of feeding magnetometer data). After this initial
rotation, it stays steadily in such position. Any movement of device
results on temporary deviation from this rotation, which is soon restored
to the "original" state. During experiments with data feed order/signs I've
recieved different results - sometimes one axis was stable, but others were
making this weird rotations. Results were 100% repetitive. If device
decided to head to some "determined" orientation, then it would reach it.
E. g. if I rotate device, then it would deviate, and then eventually come
back to this "origin" orientation. Just as if magnetometer readings
overriden acc/gyro readings.
If you choose Ax pointing North, select the other 8 sensor data in NED
order and point the device such that Ax aligns with North and leave it flat
and motionless, do you see: 0, 0, 0, 1 for the quaternion and 0, 0, 1 for
the accel, 0, 0, 0 for the gyro and Mx, My, Mz that correspond to what the
USGS says you should expect for your location? Now if you rotate the device
90 degrees and leave it flat and motionless...what do you see?
It's really difficult to conduct such tests, because of previously
mentioned issues. If I turn on the device (already calibrated, and
motionless on flat surface) it would go from 0,0,0,1 to some crazy
"predefined" orientation. If I rotate it 90 degrees (slow or fast, doesnt
matter) it would rotate, then eventually come back to origin "predefined"
orientation. Magnetometer readings vector magnitude correlates to values
expected for my location, however it's due to calibration (it scales data,
so it matches input norm value).
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKS4HSCX7KQKR7LMXJTT7KI3JANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
I believe this is not the case, since the measurements (virtualized on image from my first message) are not "drawn" to a single point. When I rotate device, the vector changes the direction uniformly around XY, XZ, YZ and planes are creating proper circle. This makes me think that I am missing something in the rest of my solution. Raw and scaled data (further passed to madgwick/mahony fusion filter) seems to be just right, but somehow magnetometer data seems to have higher weight than the rest of measurements. The only scenario that cames to my mind is that the magnetometer reading vector is somehow distorted, and the "drift-preventive" part of the filter seems to draw it into invalid direction. However im more a tinkerer, than mathematician that's why I'm asking for help, since I've been struggling with this issue for many days already :( |
Not sure there is anything I can do here. There are lots of examples
showing how to get more or less accurate quats from the ICM20948 and a
magnetometer. Nothing magic about it. I would verify that this is the case
on a breadboard away from your specific application device to be sure of
the method.
…On Sun, Aug 29, 2021 at 3:14 PM nodeMike ***@***.***> wrote:
If the heading swings rapidly to a fixed point no matter the orientation
of the device this sounds to me like the mag data is way wrong despite the
good look of your calibration surface. The mag offset biases are huge. So
if you have such a locally distorted mag field due to unavoidable
mechanical constraints then you might not be able to use 9 DoF fusion here.
Or you will have to find a way to correct for the ginormous local field. I
would think the usual hard iron correction would work but if the local
field is much larger than the Earth's field components you might never see
any change...i.e., always points to the same heading... This is not wild,
it is more or less what one would expect by putting a gigantic magnet next
to an IMU.
I believe this is not the case, since the measurements (virtualized on
image from my first message) are not "drawn" to a single point. When I
rotate device, the vector changes the direction uniformly around XY, XZ, YZ
and planes are creating proper circle. This makes me think that I am
missing something in the rest of my solution. Raw and scaled data (further
passed to madgwick/mahony fusion filter) seems to be just right, but
somehow magnetometer data seems to have higher weight than the rest of
measurements. The only scenario that cames to my mind is that the
magnetometer reading vector is somehow distorted, and the
"drift-preventive" part of the filter seems to draw it into invalid
direction. However im more a tinkerer, than mathematician that's why I'm
asking for help, since I've been struggling with this issue for many days
already :(
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKSMGXAFY7GZ67LXROLT7KWKVANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
After temporarily removing the source of magnetic field interference I've conducted same test. While the calibration wasnt "that extreme", the final results were very same. For tests I was using Arduino's implementation of Madgwick filter which can be found here: Test procedure:
Is it normal for quaternion to initially reach some "predetermined" orientation (its like 210 degrees rotation)? |
If the sensors are properly calibrated it is normal for the quaternion to
show 0 0 0 1 when pointed at magnetic north. The heading should show
whatever heading Ax (assuming this is what you chose as North) is pointed
at.
…On Mon, Aug 30, 2021 at 11:44 AM nodeMike ***@***.***> wrote:
Not sure there is anything I can do here. There are lots of examples
showing how to get more or less accurate quats from the ICM20948 and a
magnetometer. Nothing magic about it. I would verify that this is the case
on a breadboard away from your specific application device to be sure of
the method.
After temporarily removing the source of magnetic field interference I've
conducted same test. While the calibration wasnt "that extreme", the final
results were very same.
For tests I was using Arduino's implementation of Madgwick filter which
can be found here:
https://github.com/arduino-libraries/MadgwickAHRS/blob/master/src/MadgwickAHRS.cpp
Test procedure:
1. Turned off module, standing motionless on flat surface
2. Turning on, init device.
3. Device starts reading IMU and executes mentioned implementation of
madgwick filter (data feed in X, Y, Z order - NWU).
4. Quaternion rotates untill it achieves some "predetermined"
orientation, then holds it. It happens everytime quaternion values are
reset (1,0,0,0 w,x,y,z). Increasing "beta" parameter of filter just
shortens the time the process occurs.
Is it normal for quaternion to initially reach some "predetermined"
orientation (its like 210 degrees rotation)?
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKXEBJIQDSNAZLVNOYTT7PGQFANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
I've chosen X axis as north (in NWU). If I rotate the device in a way, that Mag x/y/z are 1/0/0 (normalized values) then my Acc reads -1/0/0. Madgwick's filter quickly rotates from there (to some other angle). If Acc values are statically overriden with 0/0/1 (typical readings when device is flat) then the result quaternion is indeed 0/0/0/1 (and stable). After many many hours of experimenting I've reached somehow acceptable results in terms of drift elimination, however when rotating device around "Z" axis, rotation seems to be "offsetted" by an angle. Occurs only while using magnetometer data. After further investigation, I've noticed that XZ plane is somehow "twisted" by an angle disturbingly similiar to the "offset" I was noticing. This tilt occurs only on this specific axis and I believe it is the cause of "offsetted" angle. However I have little-to-none ideas how could I fix such issue... Magneto calibration doesnt seems to be covering it. |
So when heading is 0 degrees the accel x-axis will point to magnetic North.
Where I am there is a -13.3 degree offset (called magnetic declination)
that has to be included such that 0 degrees means True North. In your area
it will be different. Check the USGS and include the declination in your
heading estimation.
Not sure this will cure your offset issue, but this is the right thing to
do for accurate absolute orientation estimation.
…On Tue, Aug 31, 2021 at 1:35 PM nodeMike ***@***.***> wrote:
If the sensors are properly calibrated it is normal for the quaternion to
show 0 0 0 1 when pointed at magnetic north. The heading should show
whatever heading Ax (assuming this is what you chose as North) is pointed
at.
I've chosen X axis as north (in NWU). If I rotate the device in a way,
that Mag x/y/z are 1/0/0 (normalized values) then my Acc reads -1/0/0.
Madgwick's filter quickly rotates from there (to some other angle). If Acc
values are statically overriden with 0/0/1 (typical readings when device is
flat) then the result quaternion is indeed 0/0/0/1 (and stable).
After many many hours of experimenting I've reached somehow acceptable
results in terms of drift elimination, however when rotating device around
"Z" axis, rotation seems to be "offsetted" by an angle. Occurs only while
using magnetometer data. After further investigation, I've noticed that XZ
plane is somehow "twisted" by an angle disturbingly similiar to the
"offset" I was noticing.
[image: Zrzut ekranu 2021-08-31 21 11 21]
<https://user-images.githubusercontent.com/73556998/131569991-79288b7b-c3b9-4c3f-a225-0552f724e276.png>
This tilt occurs only on this specific axis and I believe it is the cause
of "offsetted" angle. However I have little-to-none ideas how could I fix
such issue... Magneto calibration doesnt seems to be covering it.
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKUIQYZ7IC6YQHSW5C3T7U4JZANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
Im not operating on yaw/pitch/roll values. I'm using Unity engine to visualize orientation of my device with calculated quaternions. I believe there is no need for compensation of magnetic declination, since my goal is not to get "absolute" orientation, but "relative" to the lab environment. However, if my case requires such compensation, please correct me. What's interesting - I've noticed that one of headings seems to be not affected by this "angle offset". If device lays on flat surface, and is observed from top, the observations are: Device is rotated by 90 degrees every "step" and in three of four cases it "overshoots", however one "side" is always correct (the same, no matter how many rotations and directions I've made during tests). |
Looks like hard iron error to me.
…On Tue, Aug 31, 2021 at 3:11 PM nodeMike ***@***.***> wrote:
So when heading is 0 degrees the accel x-axis will point to magnetic
North. Where I am there is a -13.3 degree offset (called magnetic
declination) that has to be included such that 0 degrees means True North.
In your area it will be different. Check the USGS and include the
declination in your heading estimation. Not sure this will cure your offset
issue, but this is the right thing to do for accurate absolute orientation
estimation.
Im not operating on yaw/pitch/roll values. I'm using Unity engine to
visualize orientation of my device with calculated quaternions. I believe
there is no need for compensation of magnetic declination, since my goal is
not to get "absolute" orientation, but "relative" to the lab environment.
However, if my case requires such compensation, please correct me.
What's interesting - I've noticed that one of headings seems to be not
affected by this "angle offset". If device lays on flat surface, and is
observed from top, the observations are:
[image: Bez tytułu]
<https://user-images.githubusercontent.com/73556998/131582125-4b7d3c05-0f08-40e9-a7d1-28e2b170cb64.png>
Device is rotated by 90 degrees every "step" and in three of four cases it
"overshoots", however one "side" is always correct (the same, no matter how
many rotations and directions I've made during tests).
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKQHC73YKTWH3RKS6ATT7VHQTANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
But could it "hide" in the calibration results visualisation I've attached to the first message? I would expect some visible offset from the center, however it is not there... |
The kind of basic accel/gyro/mag calibration most people do can "hide" a
lot of error in both mag and accel/gyro. There are cross-axis errors and
scale errors and offset bias errors for all sensors, residual hard and soft
iron errors for the mag,, sensor-to-sensor axis alignment errors, local
field-induced errors, etc.
The 90-degree turning test is the simplest that will show this error. I
usually see something like what you are seeing when I use the basic
calibration methods, even when I use the sophisticated ellipsoidal
soft-iron calibration from Freescale (equivalent to the magneto calibration
you are using. The fact is, cell phone IMUs aren't perfect in their
response but their imperfections can be calibrated to yield nearly perfect
results.
The calibration methods
<https://www.tindie.com/products/onehorse/usfsmax-module-and-carrier/> to
do so are proprietary.
…On Tue, Aug 31, 2021 at 3:32 PM nodeMike ***@***.***> wrote:
Looks like hard iron error to me.
But could it "hide" in the calibration results visualisation I've attached
to the first message? I would expect some visible offset from the center,
however it is not there...
—
You are receiving this because you commented.
Reply to this email directly, view it on GitHub
<#467 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ABTDLKRX5TSTDUCXQGDGKHDT7VJ6TANCNFSM5DAKQ7OQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
|
Hello,
I've encountered huge issue during (lengthy) development of my device. When Im running madgwick without magnetometer readings, the orientation quaternions is pretty accurate, however obviously prone to drift (not huge). However if I use magnetometer readings in sensor fusion, the quaternion goes totally wild. It looks like magnetometer readings completely override gyro/acc measurements, and somehow "forces" orientation (if I rotate module, it goes back to specific, somehow, predetermined orientation as if magnetometer overriden acc/gyro after some cycles). Axes of sensors are aligned correctly (im using ICM-20948 chip, and aligned axes according to documentation, and many other ICM-20948 repositories I've found). When not using magnetometer readings, calculated quaternion is correct, so it narrows everything down to magnetometer readings. I've even tried all possible combinations of X,Y,Z (including inverting signs of axes), without any success. Magnetometer is calibrated with "Magneto" app, and the results seems to be good:
Im struggling with this issue for days, and I thought maybe someone here could put me out of misery... I've also tested few different implementation of both Madgwick and Mahony filters, yet the same issue occurs. Am I missing something?
Thanks!
The text was updated successfully, but these errors were encountered: