This describes the Z-Wave device ZW078, manufactured by AEON Labs with the thing type UID of aeon_zw078_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW078 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Wall mounted switch for high current appliances, up to 40A. Power reporting.
Press the Action Button on your Heavy Duty Smart Switch
If your switch has been successfully linked to your Z-Wave network, its Status LED will no longer blink. If the linking was unsuccessful, the Status LED continues to blink.
Press the Action Button on your Heavy Duty Smart Switch.
If your Heavy Duty Smart Switch has been successfully removed from your network, its Status LED will blink. If the removal was unsuccessful, its Status LED will not blink.
The following table summarises the channels available for the ZW078 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Sensor (internal temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
This is the temperature of the circuit board. The sensor is inside the case at the top of the unit.
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
The following table provides a summary of the 12 configuration parameters available in the ZW078. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Current Overload Protection | Load will be closed when current more that 39.5A and time more 5 seconds |
20 | Output Load Status | Configure the output load status after re‐power on. |
80 | Notification on Status Change | Send to group 1 on load change |
90 | Send report on value change | Toggle automated report sending on change |
91 | Minimum Change to send Report (Watt) | The value represents the minimum change in Wattage for a Report to be sent. |
92 | Minimum Change to send Report (%) | Percent change in wattage to send report |
101 | reports to send automatically | See overview |
102 | which reports to send to group 2 | see overview |
103 | which reports to send to group 3 | see overview |
111 | Interval to send out reports of group 1 | |
112 | Interval to send out reports of group 2 | |
113 | Interval to send out reports of group 3 | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Load will be closed when current more that 39.5A and time more 5 seconds
The following option values may be configured -:
Value | Description |
---|---|
0 | Deactivate |
1 | Activate |
The manufacturer defined default value is 0
(Deactivate).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Configure the output load status after re‐power on.
The following option values may be configured -:
Value | Description |
---|---|
0 | Last Status |
1 | Always ON |
2 | Always OFF |
The manufacturer defined default value is 0
(Last Status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Send to group 1 on load change Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Switch's load changed The following option values may be configured -:
Value | Description |
---|---|
0 | Deactivate |
1 | Hail CC Sent |
2 | Basic CC Report Sent |
The manufacturer defined default value is 0
(Deactivate).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Toggle automated report sending on change Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value. The following option values may be configured -:
Value | Description |
---|---|
0 | Deavtivate |
1 | Activate |
The manufacturer defined default value is 0
(Deavtivate).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
The value represents the minimum change in Wattage for a Report to be sent.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Percent change in wattage to send report The value represents the minimum change in Wattage Percent for a report to be sent. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
See overview The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
see overview The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
see overview The value is a combination number made up of the sum of the values for the individual parameters.
The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW078 supports 2 association groups.
The Node IDs in Group 1 will receive Hail Command/Basic report (configurable) when Heavy Duty Smart Switch Gen5's level changed.
Association group 1 supports 5 nodes.
When the Heavy Duty Smart Switch Gen5 receives the commands Basic Set, Switch Binary Set, or Scene Activation Set it will forward the commands to all node IDs (in Group 2).
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MARK_V1 |