layout title
documentation
MT02646 - ZWave

{% include base.html %}

MT02646 Home Control Metering Plug

This describes the Z-Wave device MT02646, manufactured by Devolo with the thing type UID of devolo_mt02646_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

MT02646 product image

The MT02646 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Home Control Smart Metering Plug can be plugged into any wall outlet in the home. It enhances every
connected device with useful functions, such as time-controlled enabling and disabling or power monitoring

Inclusion Information

Push the front button three times rapidly within 2 seconds.

Exclusion Information

Push the front button three times rapidly within 2 seconds.

Channels

The following table summarises the channels available for the MT02646 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset the total power consumption

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the MT02646. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt Meter Report Period multiples of 5s
2 KWH Meter Report Period number of 10 minute intervals
3 Threshold of current for Load Caution 1300*0.01A = 13A
4 Threshold of KWh for Load Caution load caution threshold
5 Restore switch state mode Restore switch state mode.
6 Mode of switch off function Mode of switch off function.
7 LED indication mode Restore switch state mode.
8 Auto off timer Auto off timer. 0 will disable the auto off function.
9 RF off command mode RF off command mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Watt Meter Report Period

multiples of 5s Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:

Value Description
0 Disable

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KWH Meter Report Period

number of 10 minute intervals Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function. The following option values may be configured -:

Value Description
0 Disable

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold of current for Load Caution

1300*0.01A = 13A

Values in the range 10 to 1300 may be set.

The manufacturer defined default value is 1300.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Threshold of KWh for Load Caution

load caution threshold Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Restore switch state mode

Restore switch state mode.

The following option values may be configured -:

Value Description
0 Switch OFF after power on
1 resume previous state
2 Switch ON after power on

The manufacturer defined default value is 1 (resume previous state).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Mode of switch off function

Mode of switch off function.

The following option values may be configured -:

Value Description
0 SWITCH OFF commands received are ignored.
1 SWITCH OFF commands received are honored.

The manufacturer defined default value is 1 (SWITCH OFF commands received are honored.).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: LED indication mode

Restore switch state mode.

The following option values may be configured -:

Value Description
1 The LED follows the state of the switch.
2 LED off with load ON
3 Flash mode

The manufacturer defined default value is 1 (The LED follows the state of the switch.).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto off timer

Auto off timer. 0 will disable the auto off function.

The following option values may be configured -:

Value Description
0 Disable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: RF off command mode

RF off command mode

The following option values may be configured -:

Value Description
0 SWITCH ALL OFF turns Switch OFF
1 Ignore ALL OFF
2 If ALL OFF is received, turn ON if it is OFF
3 SWITCH ALL OFF turns Switch ON

The manufacturer defined default value is 0 (SWITCH ALL OFF turns Switch OFF).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MT02646 supports 1 association group.

Group 1: Reports

Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links