layout title
documentation
FGT001 - ZWave

{% include base.html %}

FGT001 Thermostatic Valve

This describes the Z-Wave device FGT001, manufactured by Fibargroup with the thing type UID of fibaro_fgt001_00_000.

The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.

FGT001 product image

The FGT001 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

FIBARO Heat Controller is a remotely controlled thermostatic head to control temperature in the room. It measures the temperature and automatically adjust the heat level. It can be mounted without tools on three types of thermostatic radiator valves. It is also possible to create schedules via app to easily manage temperature throughout the week.
Main features:

  • to be installed on three types of valves: M30 x 1.5, Danfoss RTD-N and Danfoss RA-N,
  • compatible with any Z-Wave or Z-Wave+ Controller,
  • supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption,
  • built-in battery recharged through standard micro-USB port,
  • easy installation - no tools required,
  • can use dedicated temperature sensor,
  • supports heating schedules,
  • automatic calibration,
  • anti-freeze function,
  • decalc function,
  • unconstrained rotation spherical knob to set desired temperature.

Inclusion Information

Add the device to the Z-Wave network:

  1. Make sure the device is within the direct range of your Z-Wave controller.
  2. Set the main controller in (security/non-security) add mode.
  3. Use the included key to quickly triple click the button on the thermostatic head.
  4. The LED ring will start blinking white.
  5. If you are adding in S2 authenticated mode, type in the device pin code (underlined part of the public key on the label).
  6. Wait for the adding process to end.
  7. Successful adding will be confirmed by the Z-Wave controller.

Exclusion Information

To remove the device from the Z-Wave network:

  1. Make sure the device is within the direct range of your Z-Wave controller.
  2. Set the main controller into remove mode.
  3. Use the included key to quickly triple click the button on the thermostatic head.
  4. The LED ring will start blinking white.
  5. Wait for the removing process to end.
  6. Successful removing will be confirmed by the Z-Wave controller.

General Usage Information

Channels

The following table summarises the channels available for the FGT001 -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Alarm (power) alarm_power alarm_power Energy Switch
Alarm (system) alarm_system alarm_system Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number
Thermostat mode 1 thermostat_mode1 thermostat_mode Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Alarm (power) 1 alarm_power1 alarm_power Energy Switch
Alarm (system) 1 alarm_system1 alarm_system Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset 1 time_offset1 time_offset Time Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature
Alarm (power) 2 alarm_power2 alarm_power Energy Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm (power) 1

Indicates if a power alarm is triggered.

The alarm_power1 channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (system) 1

Indicates if a system alarm is triggered.

The alarm_system1 channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level1 channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset 1

Provides the current time difference for the devices time.

The time_offset1 channel is of type time_offset and supports the Number item and is in the Time category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Alarm (power) 2

Indicates if a power alarm is triggered.

The alarm_power2 channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level2 channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the FGT001. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Override Schedule duration Duration of Override Schedule after turning knob
2 Additional functions This parameter allows to enable different additional functions of the device.
3 Additional functions status (READ-ONLY) This parameter allows to check statuses of different additional functions.

Parameter 1: Override Schedule duration

Duration of Override Schedule after turning knob This parameter determines duration of Override Schedule after turning the knob while normal schedule is active (set by Schedule CC).

Units = minutes Values in the range 10 to 10000 may be set.

The manufacturer defined default value is 240.

This parameter has the configuration ID config_1_4 and is of type INTEGER.

Parameter 2: Additional functions

This parameter allows to enable different additional functions of the device. Parameter 2 values may be combined, e.g. 1+8=9 means that Open Window Detector and LED indications when controlling remotely are enabled.

1 (bit 0) - enable Open Window Detector

2 (bit 1) - enable fast Open Window Detector

4 (bit 2) - increase receiver sensitivity (shortens battery life)

8 (bit 3) - enabled LED indications when controlling remotely

16 (bit 4) - protect from setting Full ON and Full OFF mode by turning the knob manually

32 (bit 5) - device mounted in vertical position

64 (bit 6) - moderate regulator behaviour (instead of Rapid)

128 (bit 7) - inverted knob operation

256 (bit 8) - report when heating medium is required

512 (bit 9) - detecting heating system failures Values in the range 0 to 1023 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_4 and is of type INTEGER.

Parameter 3: Additional functions status (READ-ONLY)

This parameter allows to check statuses of different additional functions. Parameter 3 values may be combined, e.g. 1+2=3 means optional sensor works properly and open window detection was triggered.

1 (bit 0) - optional temperature sensor connected and operational

2 (bit 1) - open window detected

4 (bit 2) - provide heat in order to maintain set temperature

8 (bit 3) - malfunctioning heating system (cannot reach set temperature) Values in the range 0 to 15 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_4 and is of type INTEGER. This is a read only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FGT001 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Z-Wave Plus Lifeline association group that reports the device status and allows for assigning single device only (main controller by default)

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_SCHEDULE_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_SCHEDULE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Documentation Links