GE 12730 (ZW4002) - ZWave |
{% include base.html %}
This describes the Z-Wave device GE 12730 (ZW4002), manufactured by Jasco Products with the thing type UID of ge_12730zw4002_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The GE 12730 (ZW4002) supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
- Includes white and light almond paddles that will match most standard wall plates (wall plate not included).
- Can be controlled in groups of multiple devices.
- Easily locate the switch in a dark room with the integrated blue LED indicator.
- Use by itself or with up to four GE add-on switches in three, four, five and six-way wiring configurations.
- Brand: GE/Jasco
- Model Number: 12730
- Z-Wave Cert Number: ZC08-14110015
- Follow the instructions for your Z-wave certified controller to include a device to the Z-wave network.
- Once the controller is ready to include your device, press and release the top or bottom of the smart fan control switch (rocker) to include it in the network. Note: Your controller may need to be within 10 feet of the device to be included.
- Once your controller has confirmed that the device has been included, refresh the Z-wave network to optimize performance.
Please reference the controller/gateway’s manual for instructions. Now you have complete control to turn your fixture ON/OFF and adjust fan speed levels according to groups, scenes, schedules and interactive automation programmed by your controller. If your Z-wave certified controller features Remote Access, you can now control your fixture from your mobile devices.
Note: To exclude and reset the device, follow the instructions provided by your Z-Wave controller
- Follow the instructions for your Z-wave certified controller to exclude a device to the Z-wave network.
- Once the controller is ready to exclude your device, press and release the top or bottom of the smart fan control switch (rocker) to exclude it in the network. Note: Your controller may need to be within 10 feet of the device to be exclude.
- Once your controller has confirmed that the device has been excluded, refresh the Z-wave network to optimize performance.
The following table summarises the channels available for the GE 12730 (ZW4002) -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 8 configuration parameters available in the GE 12730 (ZW4002). Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED Light | Sets when the LED on the switch is lit. |
4 | Invert Switch | Invert Switch |
7 | Z-Wave Command Dim Step | Z-Wave Command Dim Step |
8 | Z-Wave Command Dim Rate | Z-Wave Command Dim Rate |
9 | Local Control Dim Step | Local Control Dim Step |
10 | Local Control Dim Rate | Local Control Dim Rate |
11 | ALL ON/ALL OFF Dim Step | ALL ON/ALL OFF Dim Step |
12 | ALL ON/ALL OFF Dim Rate | ALL ON/ALL OFF Dim Rate |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Sets when the LED on the switch is lit.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when light off |
1 | LED on when light on |
2 | LED always off |
The manufacturer defined default value is 0
(LED on when light off).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON, if the switch was installed upside down. The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Z-Wave Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Z-Wave Command Dim Rate This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.
. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Local Control Dim Rate This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.
. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
ALL ON/ALL OFF Dim Rate This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is 3. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.