layout | title |
---|---|
documentation |
28177 - ZWave |
{% include base.html %}
This describes the Z-Wave device 28177, manufactured by Jasco Products with the thing type UID of ge_28177_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The 28177 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Transform any home into a smart home with the plug-in GE Z-Wave Plus 2-Outlet Smart Switch with 2 USB Ports. The dual USB ports allow the Z-Wave switch to function as a wall charger for USB compatible devices. The smart switch enables you to wirelessly control to turn lights on and off, schedule a timed event or create a custom scene from anywhere in the world, at any time of the day. Helping to cut energy costs and keep your home safe, it also features a space-saving, horizontal design keeps one outlet free for your convenience and full Z-Wave control from smartphones, tablets, PC's and Z-Wave enabled wireless remotes. Take control of your home lighting with GE Z-Wave Plus 2-Outlet Smart Switch with dual USB charging Ports!
Once the controller is ready to add your smart switch, single press and release the manual/program button on the smart switch to add it in the network.
Once the controller is ready to Exclude your device, press and release the manual/program button on the smart switch to remove it from the network
The following table summarises the channels available for the 28177 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 1 configuration parameters available in the 28177. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | Defines the behavior of the blue LED. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Defines the behavior of the blue LED.
The following option values may be configured -:
Value | Description |
---|---|
1 | LED on when switch is OFF |
2 | LED Light Always ON |
The manufacturer defined default value is 1
(LED on when switch is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 28177 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline
Association group 1 supports 5 nodes.
Group 2 supports Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
Group 3 supports Basic Set and is controlled by double pressing the On or Off button
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.