ZW3101 Lamp Module

This describes the Z-Wave device ZW3101, manufactured by Jasco Products with the thing type UID of ge_zw3101_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW3101 product image

The ZW3101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Plug in lamp module with on/off/dimming control on front of device.

Inclusion Information

  1. Plug in ZW3101
  2. Place controller in inclusion mode
  3. Press button on face of ZW3101

Exclusion Information

  1. Place controller in exclusion mode
  2. Press button on front of ZW3101

Channels

The following table summarises the channels available for the ZW3101 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the ZW3101. Detailed information on each parameter can be found in the sections below.

Param Name Description
5 Ignore Start-Level (Receiving) This dimmer will start dimming from its current level.
7 On/Off Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
8 On/Off Command Dim Rate Dim Rate
9 Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step.
10 Local Control Dim Rate Local Control Dim Rate
11 ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
12 ALL ON/ALL OFF Dim Rate
29 Load Sensing
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 5: Ignore Start-Level (Receiving)

This dimmer will start dimming from its current level.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: On/Off Command Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: On/Off Command Dim Rate

Dim Rate

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Local Control Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Control Dim Rate

Local Control Dim Rate

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ALL ON/ALL OFF Dim Rate

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 29: Load Sensing

The following option values may be configured -:

Value Description
0 Load sensing is disabled
1 Load sensing is enabled

The manufacturer defined default value is 0 (Load sensing is disabled).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_VERSION_V1