ZW6302 Portable Smart Motion Sensor

This describes the Z-Wave device ZW6302, manufactured by Jasco Products with the thing type UID of ge_zw6302_00_000.

The device is in the category of Motion Detector, defining Motion sensors/detectors.

ZW6302 product image

The ZW6302 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZW6302 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Make the move toward convenience with the Z-Wave Portable Smart Motion Sensor for your home.  This Z-Wave compatible device boosts the safety of your home by working with your home’s gateway  to wirelessly trigger scenes and send alerts to your smartphone or tablet whenever motion is detected. 
Use the included batteries for easy placement anywhere, plug into the wall using a AC adapter and  USB cable – never replace batteries again. 

Inclusion Information

Once the controller is ready to include your motion sensor, press and release the button on the sensor to include it in the network

Exclusion Information

Once the controller is ready to exclude your motion sensor, press and release the button on the sensor to exclude it from the network. 

Wakeup Information

The ZW6302 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Press and release the button on the sensor

Channels

The following table summarises the channels available for the ZW6302 -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Motion Alarm alarm_motion alarm_motion Motion Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Motion Alarm

Indicates if a motion alarm is triggered.

The alarm_motion channel is of type alarm_motion and supports the Switch item and is in the Motion category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the ZW6302. Detailed information on each parameter can be found in the sections below.

Param Name Description
13 Motion Sensor Motion Sensor
18 PIR Timeout Duration PIR Timeout Duration in Minutes
20 Basic Set, Notification and Basic Report Basic Set, Notification and Basic Report
28 Enable & Disable the LED indication Enable & Disable the LED indication
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 13: Motion Sensor

Motion Sensor Detect Motion The following option values may be configured -:

Value Description
1 Low Sensitivity
2 Medium Sensitivity
3 High Sensitivity

The manufacturer defined default value is 3 (High Sensitivity).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 18: PIR Timeout Duration

PIR Timeout Duration in Minutes

The following option values may be configured, in addition to values in the range 1 to 60 -:

Value Description
1 One Minute
2 Two Minutes
5 Five Minutes
10 Ten Minutes
255 Test Mode [5 seconds]

The manufacturer defined default value is 60.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 20: Basic Set, Notification and Basic Report

Basic Set, Notification and Basic Report

The following option values may be configured -:

Value Description
1 Motion Sensor will send out Notification
2 Motion Sensor will send out Basic Set
3 Motion Sensor will sendout Basic Report

The manufacturer defined default value is 1 (Motion Sensor will send out Notification).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 28: Enable & Disable the LED indication

Enable & Disable the LED indication Enable & Disable the LED indication when PIR is triggered The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_28_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW6302 supports 1 association group.

Group 1: ZW6302

Portable Smart Motion Sensor Group 1 supports Z-Wave Plus lifeline communication and notification. lifeline association only supports the "manual reset" event and notification report, however it can be changed to send basic set with notification and basic report with notification. See programming instructions.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.