layout | title |
---|---|
documentation |
ZW6302 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW6302, manufactured by Jasco Products with the thing type UID of ge_zw6302_00_000
.
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The ZW6302 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW6302 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Make the move toward convenience with the Z-Wave Portable Smart Motion Sensor for your home. This Z-Wave compatible device boosts the safety of your home by working with your home’s gateway to wirelessly trigger scenes and send alerts to your smartphone or tablet whenever motion is detected.
Use the included batteries for easy placement anywhere, plug into the wall using a AC adapter and USB cable – never replace batteries again.
Once the controller is ready to include your motion sensor, press and release the button on the sensor to include it in the network
Once the controller is ready to exclude your motion sensor, press and release the button on the sensor to exclude it from the network.
The ZW6302 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press and release the button on the sensor
The following table summarises the channels available for the ZW6302 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Motion Alarm | alarm_motion | alarm_motion | Motion | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if a motion alarm is triggered.
The alarm_motion
channel is of type alarm_motion
and supports the Switch
item and is in the Motion
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 4 configuration parameters available in the ZW6302. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
13 | Motion Sensor | Motion Sensor |
18 | PIR Timeout Duration | PIR Timeout Duration in Minutes |
20 | Basic Set, Notification and Basic Report | Basic Set, Notification and Basic Report |
28 | Enable & Disable the LED indication | Enable & Disable the LED indication |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Motion Sensor Detect Motion The following option values may be configured -:
Value | Description |
---|---|
1 | Low Sensitivity |
2 | Medium Sensitivity |
3 | High Sensitivity |
The manufacturer defined default value is 3
(High Sensitivity).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
PIR Timeout Duration in Minutes
The following option values may be configured, in addition to values in the range 1 to 60 -:
Value | Description |
---|---|
1 | One Minute |
2 | Two Minutes |
5 | Five Minutes |
10 | Ten Minutes |
255 | Test Mode [5 seconds] |
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Basic Set, Notification and Basic Report
The following option values may be configured -:
Value | Description |
---|---|
1 | Motion Sensor will send out Notification |
2 | Motion Sensor will send out Basic Set |
3 | Motion Sensor will sendout Basic Report |
The manufacturer defined default value is 1
(Motion Sensor will send out Notification).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Enable & Disable the LED indication Enable & Disable the LED indication when PIR is triggered The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 1
(Enable).
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW6302 supports 1 association group.
Portable Smart Motion Sensor Group 1 supports Z-Wave Plus lifeline communication and notification. lifeline association only supports the "manual reset" event and notification report, however it can be changed to send basic set with notification and basic report with notification. See programming instructions.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.