DX1CG-Z - ZWave

{% include base.html %}

DX1CG-Z CH4 Gas Sensor

This describes the Z-Wave device DX1CG-Z, manufactured by Heiman Technology Co. Ltd with the thing type UID of heiman_dx1cgz_00_000.

The device is in the category of Sensor, defining Device used to measure something.

DX1CG-Z product image

The DX1CG-Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Smart Combustible Gas Sensor adopts super low power consumption Z-Wave Wireless module. Used for detecting combusting gas leakage and preventing danger caused by gas leakage it also can be used as Z-Wave repeater to extend wireless transmission distance. It adopts high stability semiconductor gas sensor.

Sensor alarms if gas density in air exceeds set alarm level. It is applicable for kitchen or possible gas leakage in in-door area.

Inclusion Information

Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. If add Process is successful, Green LED will turn on.

Exclusion Information

Press the Net_Button 3 times within 1.5s. If remove Process is successful, Green LED is Blinking 6 times, then turn on.

Channels

The following table summarises the channels available for the DX1CG-Z -:

Channel Name Channel ID Channel Type Category Item Type
Combustible Gas Alarm alarm_combustiblegas alarm_combustiblegas Switch

Combustible Gas Alarm

Indicates if the combustible gas alarm is triggered.

The alarm_combustiblegas channel is of type alarm_combustiblegas and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DX1CG-Z supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Group 2: Root Device group (Notifcation)

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_ALARM_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1