Skip to content

Latest commit

 

History

History
executable file
·
99 lines (62 loc) · 4.87 KB

s123a00r_0_0.md

File metadata and controls

executable file
·
99 lines (62 loc) · 4.87 KB
layout title
documentation
S123A00R - ZWave

{% include base.html %}

S123A00R Z-Wave home energy meter

This describes the Z-Wave device S123A00R, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_s123a00r_00_000.

The device is in the category of Sensor, defining Device used to measure something.

S123A00R product image

The S123A00R supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The S123A00R is a single element Z-Wave electricity meter that can provide residential customers with detailed energy data for electricity usage.

Inclusion Information

With the meter in installer mode the following procedure needs to be carried out with the third party controller in network include mode to add the meter to its network.

  1. Press and hold the blue button for 2 seconds (enters Installer Displays).
  2. Cycle through each menu display item with single presses until the display shows “LEArn”. Do not press the blue button again unless repeating the process.
  3. Wait 10s and the display will show “oooo” for one second.
  4. Display will now show either “SENT” or “FAIL” (if “FAIL” wait for 30s and retry from point 2). Note if it is still not possible to obtain the “SENT” message then the meter should be powered down briefly and powered up again.

On entering this mode there is a 2 minute window to do the include or exclude process. The success of the action is indicated by a brief “PASS” or “FAIL” message on the meter’s display. A timeout will be indicated by a brief “FAIL” message. 

Exclusion Information

With the meter in installer mode the following procedure needs to be carried out with the third party controller in network exclude mode to remove the meter from its network. 

  1. Press and hold the blue button for 2 seconds (enters Installer Displays). 
  2. Cycle through each menu display item with single presses until the display shows “LEArn”. Do not press the blue button again unless repeating the process. 
  3. Wait 10s and the display will show “oooo” for one second. 
  4. Display will now show either “SENT” or “FAIL” (if “FAIL” wait for 30s and retry from point 2). Note if it is still not possible to obtain the “SENT” message then the meter should be powered down briefly and powered up again.

On entering this mode there is a 2 minute window to do the include or exclude process. The success of the action is indicated by a brief “PASS” or “FAIL” message on the meter’s display. A timeout will be indicated by a brief “FAIL” message.

Channels

The following table summarises the channels available for the S123A00R -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (power) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel is of type sensor_power and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_METER_V1
COMMAND_CLASS_METER_PULSE_V1
COMMAND_CLASS_BASIC_TARIFF_INFO_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_TIME_V1

Documentation Links