FS20Z - ZWave

{% include base.html %}

FS20Z Isolated Contact Fixture Module

This describes the Z-Wave device FS20Z, manufactured by Linear Corp with the thing type UID of linear_fs20z_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

FS20Z product image

The FS20Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

z-Wave Radio Frequency (RF) Controlled, 120 VAC Scene Capable, Isolated Contact Fixture Module

Inclusion Information

  1. Prepare the Controller to include a unit to the network, by adding it to a group (method of adding a node to the network). Refer to Controller instructions.
  2. The FS20Z-1 must be in its permanently installed location. Press the button on the FS20Z-1 once.
  3. You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.

Exclusion Information

Remove the module by tapping the button three times, then press and hold.

Channels

The following table summarises the channels available for the FS20Z -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the FS20Z. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Nightlight: LED turns ON when the switch is turned OFF

Parameter 3: Night Light

Nightlight: LED turns ON when the switch is turned OFF In night-light mode the LED on the switch will turn ON when the switch is turned OFF. The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 1 (Yes).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.