Skip to content

Latest commit

 

History

History
executable file
·
126 lines (82 loc) · 4.26 KB

pd300z2_0_0.md

File metadata and controls

executable file
·
126 lines (82 loc) · 4.26 KB
layout title
documentation
PD300Z-2 - ZWave

{% include base.html %}

PD300Z-2 Plug-in Wall Dimmer

This describes the Z-Wave device PD300Z-2, manufactured by Linear Corp with the thing type UID of linear_pd300z2_00_000.

The device is in the category of Light Bulb, defining Devices that illuminate something, such as bulbs, etc..

PD300Z-2 product image

The PD300Z-2 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

300 Watt, 120 VAC NWI and Scene Capable Plug-In Lamp Module

Inclusion Information

  1. Prepare the Controller to include a unit to the network. The PD300Z-2 must be in its permanently installed location.
  2. For NWI Inclusion, press the button on the PD300Z-2 once.
  3. For classic inclusion, press the button on the PD300Z-2 twice.

Exclusion Information

  1. Set the Controller into Removal Mode
  2. Remove the switch by press the button twice

Channels

The following table summarises the channels available for the PD300Z-2 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the PD300Z-2. Detailed information on each parameter can be found in the sections below.

Param Name Description
29 Load Sense Turn load sense on with 1, off with 0
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 29: Load Sense

Turn load sense on with 1, off with 0 Set parameter to 0 to disable load sense, set parameter to 1 to enable load sense. The following option values may be configured -:

Value Description
0 Disable load sense
1 Enable load sense

The manufacturer defined default value is 1 (Enable load sense).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.