layout | title |
---|---|
documentation |
ZHC5010 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZHC5010, manufactured by Logic Group with the thing type UID of logic_zhc5010_02_000
.
This version of the device is limited to firmware versions above 2.0
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZHC5010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
ZHC5010 is a wall switch module with Z-Wave communication. The module contains four buttons, four LEDs, a built-in relay switch and is designed to fit into a standard LK FUGA® wall box (one-module format). The ZHC5010 Wall Switch allows you to control the local load as well as Z-Wave connected devices in up to four additional Z-Wave groups.
Configuration updated: 2017-12-10, firmware 2.03
Place your primary controller in Adding Mode by following the manufacturer's instructions, then activate the add mode on the device by triple-clicking the upper left button on the module, or by triple-clicking the little button in the middle of the module (hidden behind the small plastic cover). Adding Mode is indicated by blinking of upper left LED until the timeout occurs after 10 seconds or the module has been added in the network.
Follow the inclusion procedures; the device is removed in the same manner, when the controller is in Removing Mode.
Factory reset:
ZHC5010 can be factory reset by pressing the small button in the middle of the module (normally covered by small plastic cover) for at least 10 seconds. Remove the middle plastic cover by means of a small screwdriver, and press the small button for at least 10 seconds, until all the LEDs lights up. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
The following table summarises the channels available for the ZHC5010 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Button 1 Indicator | indicator_raw | indicator_raw | String | |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Dimmer 1 | switch_dimmer1 | switch_dimmer | DimmableLight | Dimmer |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Dimmer 2 | switch_dimmer2 | switch_dimmer | DimmableLight | Dimmer |
Switch 3 | switch_binary3 | switch_binary | Switch | Switch |
Dimmer 3 | switch_dimmer3 | switch_dimmer | DimmableLight | Dimmer |
Switch 4 | switch_binary4 | switch_binary | Switch | Switch |
Dimmer 4 | switch_dimmer4 | switch_dimmer | DimmableLight | Dimmer |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Sets the indicator properties as a JSON string.
The indicator_raw
channel is of type indicator_raw
and supports the String
item.
This channel sets, and provides the indicator state as a JSON string. It is designed for use in rules.
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer1
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer2
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Switch the power on and off.
The switch_binary3
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer3
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Switch the power on and off.
The switch_binary4
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer4
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 43 configuration parameters available in the ZHC5010. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Upper paddle buttons mode | Pair Mode, upper two buttons |
2 | Lower paddle buttons mode | Pair Mode, upper two buttons |
3 | LED indication #1 | LED indication button 1 |
4 | LED indication #2 | LED indication button 2 |
5 | LED indication #3 | LED indication button 3 |
6 | LED indication #4 | LED indication button 4 |
7 | Percentage of light in the LED #1 when On | Configure the percentage of light in LED # 1, when the LED is turned on. |
8 | Percentage of light in the LED #2 when On | Configure the percentage of light in LED # 2, when the LED is turned on. |
9 | Percentage of light in the LED #3 when On | Configure the percentage of light in LED # 3, when the LED is turned on. |
10 | Percentage of light in the LED #4 when On | Configure the percentage of light in LED #4, when the LED is turned on. |
11 | Percentage of light in the LED #1 when Off | Configure the percentage of light in LED # 1, when the LED is turned off. |
12 | Percentage of light in the LED #2 when Off | Configure the percentage of light in LED # 2, when the LED is turned off. |
13 | Percentage of light in the LED #3 when Off | Configure the percentage of light in LED #3, when the LED is turned off. |
14 | Percentage of light in the LED #4 when Off | Configure the percentage of light in LED #4, when the LED is turned off. |
15 | Relay mode | How built-in relay is controlled |
16 | Indicator mode. | set the current light level for the actual LED or the level value can be stored |
17 | Scene notification offset. | Scene sequence numbers transmitted by Central Scene notifications. |
18 | Disable House Cleaning. | Disable House Cleaning Mode. |
19 | Multilevel Switch (button #1) Disabled/Enabled | Multilevel Switch on single press for device 1 (button #1) |
19 | Upper switch value - (button #1) | Multilevel Switch - Upper switch value - (button #1) |
19 | Lower switch value - (button #1) | Multilevel Switch - Lower switch value - (button #1) |
20 | Multilevel Switch (button #2) Disabled/Enabled | Multilevel Switch on single press for device 2 (button #2) |
20 | Upper switch value - (button #2) | Multilevel Switch - Upper switch value - (button #2) |
20 | Lower switch value - (button #2) | Multilevel Switch - Lower switch value - (button #2) |
21 | Multilevel Switch (button #3) Disabled/Enabled | Multilevel Switch on single press for device 3 (button #3) |
21 | Upper switch value - (button #3) | Multilevel Switch - Upper switch value - (button #3) |
21 | Lower switch value - (button #3) | Multilevel Switch - Lower switch value - (button #3) |
22 | Multilevel Switch (button #4) Disabled/Enabled | Multilevel Switch on single press for device 4 (button #4) |
22 | Upper switch value - (button #4) | Multilevel Switch - Upper switch value - (button #4) |
22 | Lower switch value - (button #4) | Multilevel Switch - Lower switch value - (button #4) |
23 | Control of association groups (button #1). | Control of association groups for device 1 (button #1). |
24 | Control of association groups (button #2). | Control of association groups for device 2 (button #2). |
25 | Control of association groups (button #3). | Control of association groups for device 3 (button #3). |
26 | Control of association groups (button #4). | Control of association groups for device 4 (button #4). |
28 | Threshold time for long-press | Decides the time for when a button is detected as long-pressed |
29 | Threshold time for keypress detection of button 1 | Specifies the detection time for single-press, double-press, etc. for button 1. |
30 | Threshold time for keypress detection of button 2 | Specifies the detection time for single-press, double-press, etc. for button 2 |
31 | Threshold time for keypress detection of button 3 | Specifies the detection time for single-press, double-press, etc. for button 3 |
32 | Threshold time for keypress detection of button 4 | Specifies the detection time for single-press, double-press, etc. for button 4 |
33 | Non-secure commands for AG in logical device 1 | Allow sending non-secure commands to association members if added securely |
34 | Non-secure commands for AG in logical device 2 | Allow sending non-secure commands to association members if added securely |
35 | Non-secure commands for AG in logical device 3 | Allow sending non-secure commands to association members if added securely |
36 | Non-secure commands for AG in logical device 4 | Allow sending non-secure commands to association members if added securely |
Pair Mode, upper two buttons Configuration of Pair Mode for the upper two buttons (button #1 and #2) The following option values may be configured -:
Value | Description |
---|---|
0 | Separate mode (toggle mode). |
1 | Pair mode |
The manufacturer defined default value is 0
(Separate mode (toggle mode).).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Pair Mode, upper two buttons Configuration of Pair Mode for the upper two buttons (button #1 and #2). The following option values may be configured -:
Value | Description |
---|---|
0 | Separate mode (toggle mode). |
1 | Pair mode |
The manufacturer defined default value is 0
(Separate mode (toggle mode).).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
LED indication button 1
The following option values may be configured -:
Value | Description |
---|---|
0 | LED indication is disabled |
1 | Indicates corresponding button |
2 | Inverted indication |
3 | Status of corresponding paddle |
4 | Corresponding paddle, with inverted indication. |
5 | Status of the built-in relay. |
6 | Status of the built-in relay, inverted indication. |
7 | 5 seconds indication |
8 | LED indication is disabled (BASIC SET) |
The manufacturer defined default value is 1
(Indicates corresponding button).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
LED indication button 2
The following option values may be configured -:
Value | Description |
---|---|
0 | LED indication is disabled |
1 | Indicates corresponding button |
2 | Inverted indication |
3 | Status of corresponding paddle |
4 | Corresponding paddle, with inverted indication. |
5 | Status of the built-in relay. |
6 | Status of the built-in relay, inverted indication. |
7 | 5 seconds indication |
8 | LED indication is disabled (BASIC SET) |
The manufacturer defined default value is 1
(Indicates corresponding button).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
LED indication button 3
The following option values may be configured -:
Value | Description |
---|---|
0 | LED indication is disabled |
1 | Indicates corresponding button |
2 | Inverted indication |
3 | Status of corresponding paddle |
4 | Corresponding paddle, with inverted indication. |
5 | Status of the built-in relay. |
6 | Status of the built-in relay, inverted indication. |
7 | 5 seconds indication |
8 | LED indication is disabled (BASIC SET) |
The manufacturer defined default value is 1
(Indicates corresponding button).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
LED indication button 4
The following option values may be configured -:
Value | Description |
---|---|
0 | LED indication is disabled |
1 | Indicates corresponding button |
2 | Inverted indication |
3 | Status of corresponding paddle |
4 | Corresponding paddle, with inverted indication. |
5 | Status of the built-in relay. |
6 | Status of the built-in relay, inverted indication. |
7 | 5 seconds indication |
8 | LED indication is disabled (BASIC SET) |
The manufacturer defined default value is 1
(Indicates corresponding button).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Configure the percentage of light in LED # 1, when the LED is turned on.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Configure the percentage of light in LED # 2, when the LED is turned on.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Configure the percentage of light in LED # 3, when the LED is turned on.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Configure the percentage of light in LED #4, when the LED is turned on.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Configure the percentage of light in LED # 1, when the LED is turned off.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Configure the percentage of light in LED # 2, when the LED is turned off.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Configure the percentage of light in LED #3, when the LED is turned off.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Configure the percentage of light in LED #4, when the LED is turned off.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
How built-in relay is controlled This parameter configures which of the buttons that shall control the built-in relay, or if the relay only will be activated for one second, each time button #1 is used. The following option values may be configured -:
Value | Description |
---|---|
0 | Relay is disabled. |
1 | Relay is controlled by button #1 |
2 | Relay is controlled by button #2 |
3 | Relay is controlled by button #3 |
4 | Relay is controlled by button #4 |
5 | Relay is activated for one second, button #1 |
6 | Relay is activated for half a second, button #2 |
7 | Relay is activated for half a second, button #3 |
8 | Relay is activated for half a second, button #4 |
9 | Relay follows the state of button #1 |
10 | Relay follows the state of button #2 |
11 | Relay follows the state of button #3 |
12 | Relay follows the state of button #4 |
13 | Relay is controlled by commands to root device |
The manufacturer defined default value is 1
(Relay is controlled by button #1).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
set the current light level for the actual LED or the level value can be stored When ZHC5010 receives an Indicator Set message, then the received value can be used only to set the current light level for the actual LED or the level value can be stored and will then be used for subsequent internal activations. The following option values may be configured -:
Value | Description |
---|---|
0 | Indicator Set used to control the LED. |
1 | Indicator Set values and internal activations. |
The manufacturer defined default value is 1
(Indicator Set values and internal activations.).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Scene sequence numbers transmitted by Central Scene notifications. Configure the scene sequence numbers that will be transmitted by Central Scene notifications.
Button #1 will send scene [value], button #2 will send scene [value] + 1, button #3 will send scene [value] + 2, button #4 will send scene [value] + 3. (Default = 1) The following option values may be configured -:
Value | Description |
---|---|
0 | Scene notifications are turned off. |
1 | Send scene value for button # |
The manufacturer defined default value is 1
(Send scene value for button #).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Disable House Cleaning Mode. This parameter is able to enable or disable the so-called “House Cleaning Mode”, where ZHC5010 is able send a dimming command in order to set the level of the lights to 100%. The following option values may be configured -:
Value | Description |
---|---|
0 | House Cleaning Mode is enabled |
1 | 1 House Cleaning Mode is disabled. |
The manufacturer defined default value is 0
(House Cleaning Mode is enabled).
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Multilevel Switch on single press for device 1 (button #1)
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_19_4_00000001
and is of type INTEGER
.
Multilevel Switch - Upper switch value - (button #1) When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_19_4_0000FF00
and is of type INTEGER
.
Multilevel Switch - Lower switch value - (button #1) When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_19_4_00FF0000
and is of type INTEGER
.
Multilevel Switch on single press for device 2 (button #2)
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_20_4_00000001
and is of type INTEGER
.
Multilevel Switch - Upper switch value - (button #2) When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_20_4_0000FF00
and is of type INTEGER
.
Multilevel Switch - Lower switch value - (button #2) When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_4_00FF0000
and is of type INTEGER
.
Multilevel Switch on single press for device 3 (button #3)
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_21_4_00000001
and is of type INTEGER
.
Multilevel Switch - Upper switch value - (button #3) When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_21_4_0000FF00
and is of type INTEGER
.
Multilevel Switch - Lower switch value - (button #3) When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_4_00FF0000
and is of type INTEGER
.
Multilevel Switch on single press for device 4 (button #4)
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_22_4_00000001
and is of type INTEGER
.
Multilevel Switch - Upper switch value - (button #4) When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 255) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_22_4_0000FF00
and is of type INTEGER
.
Multilevel Switch - Lower switch value - (button #4) When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 6. (Default = 0) Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_22_4_00FF0000
and is of type INTEGER
.
Control of association groups for device 1 (button #1). Enable or disable if received commands are relayed to the nodes in the association groups. The following option values may be configured -:
Value | Description |
---|---|
0 | Association groups will not be switched. |
1 | Association groups will be switched, |
The manufacturer defined default value is 1
(Association groups will be switched,).
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Control of association groups for device 2 (button #2). Enable or disable if received commands are relayed to the nodes in the association groups. The following option values may be configured -:
Value | Description |
---|---|
0 | Association groups will not be switched. |
1 | Association groups will be switched, |
The manufacturer defined default value is 1
(Association groups will be switched,).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Control of association groups for device 3 (button #3). Enable or disable if received commands are relayed to the nodes in the association groups. The following option values may be configured -:
Value | Description |
---|---|
0 | Association groups will not be switched. |
1 | Association groups will be switched, |
The manufacturer defined default value is 1
(Association groups will be switched,).
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Control of association groups for device 4 (button #4). Enable or disable if received commands are relayed to the nodes in the association groups. The following option values may be configured -:
Value | Description |
---|---|
0 | Association groups will not be switched. |
1 | Association groups will be switched, |
The manufacturer defined default value is 1
(Association groups will be switched,).
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
Decides the time for when a button is detected as long-pressed Decides the time for when a button is detected as long-pressed.
0 : Detection disabled. This is not recommended.
1-255 : Long-press detection time in 0.01 seconds, 50 equals 0.5 seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Specifies the detection time for single-press, double-press, etc. for button 1. Specifies the detection time for single-press, double-press, etc. for button 1.
0 : Detection disabled. This is not recommended.
1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Specifies the detection time for single-press, double-press, etc. for button 2 Specifies the detection time for single-press, double-press, etc. for button 2.
0 : Detection disabled. This is not recommended.
1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Specifies the detection time for single-press, double-press, etc. for button 3 Specifies the detection time for single-press, double-press, etc. for button 3.
0 : Detection disabled. This is not recommended.
1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Specifies the detection time for single-press, double-press, etc. for button 4 Specifies the detection time for single-press, double-press, etc. for button 4.
0 : Detection disabled. This is not recommended.
1 - 255 : Detection time in 0.01 seconds, 30 equals 0.3 seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Allow sending non-secure commands to association members if added securely If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays).
If ZHC5010 is included non-secure, this parameter has no function.
0 : No commands sent unencrypted (default)
1 (0x01) : Bit#1. Not used.
2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted.
4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted.
8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted.
16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted.
32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Allow sending non-secure commands to association members if added securely If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays).
If ZHC5010 is included non-secure, this parameter has no function.
0 : No commands sent unencrypted (default)
1 (0x01) : Bit#1. Not used.
2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted.
4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted.
8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted.
16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted.
32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Allow sending non-secure commands to association members if added securely If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays).
If ZHC5010 is included non-secure, this parameter has no function.
0 : No commands sent unencrypted (default)
1 (0x01) : Bit#1. Not used.
2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted.
4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted.
8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted.
16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted.
32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_35_1
and is of type INTEGER
.
Allow sending non-secure commands to association members if added securely If ZHC5010 is included secure, this parameter allows sending messages on keypresses to non-secure devices (e.g. pre-gen5 relays).
If ZHC5010 is included non-secure, this parameter has no function.
0 : No commands sent unencrypted (default)
1 (0x01) : Bit#1. Not used.
2 (0x02) : Bit#2. Send BASICREPORT to association group 2 unencrypted.
4 (0x04) : Bit#3. Send BASICSET to association group 3 unencrypted.
8 (0x08) : Bit#4. Send BINARYSWITCHSET to association group 4 unencrypted.
16 (0x10) : Bit#5. Send BINARYTOGGLESWITCHSET to association group 5 unencrypted.
32 (0x20) : Bit#6. Send MULTILEVELSWITCH to association group 6 unencrypted. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_36_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZHC5010 supports 21 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Sends Binary Switch Set (On/Off) when button #1 is used.
Association group 4 supports 5 nodes.
Association group 5 supports 5 nodes.
Sends Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change when button #1 is used.
Association group 6 supports 5 nodes.
Association group 7 supports 5 nodes.
Association group 8 supports 5 nodes.
Sends Binary Switch Set (On/Off) when button #2 is used.
Association group 9 supports 5 nodes.
Association group 10 supports 5 nodes.
Sends Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change when button #2 is used.
Association group 11 supports 5 nodes.
Association group 12 supports 5 nodes.
Association group 13 supports 5 nodes.
Sends Binary Switch Set (On/Off) when button #3 is used.
Association group 14 supports 5 nodes.
Send Binary Toggle Switch Set when button #3 is used.
Association group 15 supports 5 nodes.
Sends Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change when button #3 is used.
Association group 16 supports 5 nodes.
Association group 17 supports 5 nodes.
Association group 18 supports 5 nodes.
Sends Binary Switch Set (On/Off) when button #4 is used
Association group 19 supports 5 nodes.
Association group 20 supports 5 nodes.
Sends Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change when button #4 is used.
Association group 21 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_INDICATOR_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_INDICATOR_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_INDICATOR_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_INDICATOR_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.