NZW31S In-Wall Dimming Switch /w Scenes + Repeater

This describes the Z-Wave device NZW31S, manufactured by NIE Technology with the thing type UID of nietech_nzw31s_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

NZW31S product image

The NZW31S supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Inovelli's In-Wall Smart Dimmer not only has the ability to control lights from anywhere in the world, but it acts as a Z-Wave signal repeater, which amplifies your Z-Wave signal, growing the capabilities of your network. 

In addition, it has scene control enabled, which allows you to double tap the switch to activate a Z-Wave scene. An example would be a bedtime scene, which turns off all lights, locks the door(s) and sets the temperature to 68 degrees. 

Simplifying lives, one smart home product at a time... that's Inovelli.

Inclusion Information

Including Steps:

  • This will vary based on the HUB/Gateway you’re using, but you need to go one (1) step before putting your HUB/Gateway in inclusion process — once you are one (1) step away from physically starting the inclusion/pairing process — THEN STOP!
  • Walk down to your circuit breaker and flip on the power (you will now have 30 seconds to physically start the inclusion process on your HUB/Gateway)
  • While next to the breaker, start the inclusion process and your HUB/Gateway will automatically start looking for devices
  • Wait for auto-inclusion to do its thing. Your switch will automatically include/pair to your HUB/Gateway
    • If successful, your device will flash twice (NOTE: Auto-Inclusion will time out after 30 seconds)
    • If the switch does not flash within 30 seconds, please use the alternate method of pairing which is pressing the top (UP) button 6x within 2 seconds
  • Confirm that your HUB/Gateway shows the switch

Congratulations, you now have a remote controlled switch!

If you are having issues pairing your device, please ensure your switch is within range of your HUB. 95% of the pairing/including failures stem from this issue. Best practice is to start with Z-Wave products near your HUB and build your network out. The more Z-Wave devices, the more efficient your network.

Exclusion Information

  • Press the Top (UP) Button on your NZW31S six (6) times within 2 seconds

Channels

The following table summarises the channels available for the NZW31S -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the NZW31S. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Dimmer Step Configuration Dimmer Speed Setting (On/Off)
2 Dimmer Minimum Configuration Lowest dim setting before turning off
4 Switch Orientation Invert On/Off from Top/Bottom
5 Countdown Timer Shutoff Timer
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Dimmer Step Configuration

Dimmer Speed Setting (On/Off) Control the speed with which the dimmer turns on and off. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Dimmer Minimum Configuration

Lowest dim setting before turning off Lowest dim setting before turning off Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 4: Switch Orientation

Invert On/Off from Top/Bottom Invert the switch on/off position.

00 - Up = On, Down = Off

01 - Up = Off, Down = On The following option values may be configured -:

Value Description
0 Up=ON, Down=OFF
1 Up=OFF, Down=ON

The manufacturer defined default value is 0 (Up=ON, Down=OFF).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Countdown Timer

Shutoff Timer Countdown timer.

0x00 - x8000 - 0-32768 Seconds Values in the range 0 to 32768 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NZW31S supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. An association command class that allows the device to communicate with other Z-Wave devices directly -- such as sending BASIC REPORT whenever the switch is turned on or off.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3